FAQ No. FAQ001906
Question
How do you calculate the control resistance
for A3D/M2D Push Buttons LED lamps?
Answer
Set the control resistance within the range for the LED lamp
characteristics.
(Set the forward current for the LED lamp to 8 mA min.)
Use the following formula to find the external resistance.

Control Resistance (Recommended Values)
|
Voltage |
Red |
Yellow
(White) |
Green |
| 5 VDC |
165 Ω |
140 Ω |
165 Ω |
| 12 VDC |
515 Ω |
490 Ω |
515 Ω |
| 24 VDC |
1,100 Ω |
1,090 Ω |
1,100 Ω |
Calculation Example: A3D
LED lamp color: Red
When E=24V, IF=20mA, and Ta=25°C:
Based on the VF-IF characteristics in the diagram below (red), VF when IF
= 20mA will be 1.7 V.
If this value is entered into the above formula, the result is as follows:

The recommended resistance is 1.1 kΩ 1 W (2 × IF2R). A margin of
approximately two times is appropriate for the resistance capacity.


Applicable models: A3D,
A3A Push Buttons etc.