EN/IEC Standards
|
Model |
CE Marking |
Safety Category |
Applicable
Directive |
Machinery
Directive/
Low-voltage Directive |
EMC Directive |
|
E5CN |
Yes |
B |
•
(See note) |
•
(See note) |
We issue documentation ("EC Declaration of
Conformity") providing details on the level of conformance. Contact your OMRON
representative if required.
UL Certifications
|
Model |
Input Ratings |
File No. |
Marking |
Listed/ Recognized |
Category |
E5CN |
AC100 to 240V AC/DC24V |
E200593
|
cULus |
Listed |
QUYX/QUYX7 |
CSA Certification
|
Model |
Input Ratings |
Standard No. |
File No. |
E5CN |
AC100 to 240V AC/DC24V |
Evaluated by UL. |
KOSHA Certification
|
Model |
Standard No. |
Certification No. |
|
E5CN-RQ203T-FLK AC100-240 |
EN61010-1 |
2008-210(1) to
210(6) |
|
E5CN-C2PBT
AC100-240 |
|
E5CN-R2P03T-FLK
AC100-240 |
|
E5CN-Q2P03T-FLK
AC100-240 |
|
E5CN-CQ2BTD
AC/DC24 |
|
E5CN-RTD AC/DC24 |
|
E5CN-QTD AC/DC24 |
|
E5CN-CTD AC/DC24 |
|
E5CN-R2TD AC/DC24 |
|
E5CN-Q2TD AC/DC24 |
|
E5CN-C2TD AC/DC24 |
|
E5CN-R2HBTD
AC/DC24 |
|
E5CN-Q2HBTD
AC/DC24 |
|
E5CN-C2BTD
AC/DC24 |
|
E5CN-R2H03TD-FLK
AC/DC24 |
|
E5CN-Q2H03TD-FLK
AC/DC24 |
|
E5CN-C203TD-FLK
AC/DC24 |
|
E5CN-R2HH03TD-FLK AC/DC24 |
|
E5CN-Q2HH03TD-FLK
AC/DC24 |
|
E5CN-QQ203TD-FLK
AC/DC24 |
|
E5CN-CQ203TD-FLK
AC/DC24 |
|
E5CN-QQ2HTD AC/DC24 |
|
E5CN-RT AC100-240 |
|
E5CN-QT AC100-240 |
|
E5CN-CT AC100-240 |
|
E5CN-R2T
AC100-240 |
|
E5CN-Q2T
AC100-240 |
|
E5CN-C2T
AC100-240 |
|
E5CN-R2HBT
AC100-240 |
|
E5CN-Q2HBT AC100-240 |
|
E5CN-C2BT
AC100-240 |
|
E5CN-R2H03T-FLK
AC100-240 |
|
E5CN-Q2H03T-FLK
AC100-240 |
|
E5CN-C203T-FLK
AC100-240 |
|
E5CN-R2HH03T-FLK AC100-240 |
|
E5CN-Q2HH03T-FLK
AC100-240 |
|
E5CN-QQ203T-FLK
AC100-240 |
|
E5CN-CQ203T-FLK
AC100-240 |
|
E5CN-QQ2HT
AC100-240 |
|
E5CN-Y2T
AC100-240 |
|
E5CN-Y2HBT
AC100-240 |
|
E5CN-Y2H03T-FLK
AC100-240 |
|
E5CN-Y2HH03T-FLK
AC100-240 |
|
E5CN-R2PBT
AC100-240 |
|
E5CN-Q2PBT
AC100-240 |
|
E5CN-R2PHT
AC100-240 |
|
E5CN-Q2PHT
AC100-240 |
|
E5CN-CQ2HT
AC100-240 |
|
E5CN-RQ2HT
AC100-240 |
|
E5CN-CQ2HHT
AC100-240 |
|
E5CN-QQ2HHT AC100-240 |
|
E5CN-RQ2HHT
AC100-240 |
|
E5CN-CQ2BT
AC100-240 |
|
E5CN-QQ2BT AC100-240 |
|
E5CN-RQ2BT AC100-240 |
LR Standards
|
Model |
Ratings |
Environmental
Category |
|
ENV1 |
ENV2 |
ENV3 |
ENV4 |
ENV5 |
Remarks |
|
E5CN |
24VAC/DC
100-240VAC |
• |
• |
|
|
|
General power distribution
zones
|
Note:
1. The
above table lists series names. Ask your OMRON representative for details on
specific model numbers.
2. Model certification has not been received for usage on the deck, in the
bridge, or in locations subject to strong vibration.
Model
certification for the LR was made according to the LR Type Approval System Test
Specification No. 1. Refer to the following table for environmental categories.
|
ENV1 |
Controlled environments
only, to producer's specification |
|
ENV2 |
Enclosed spaces
subject to temperature, humidity and vibration: 5 to 55ºC |
|
ENV3 |
Enclosed spaces
subject to generated heat from other equipment: 5 to 70ºC |
|
ENV4 |
Mounted on reciprocating
machinery: 5 to 55ºC |
|
ENV5 |
Open decks: -25
to 70ºC |
Note:
Models that are certified for an ENV2 environment can also be used in an ENV1
environment.
|