Industrial Automation|

India

Sitemap

Contact

OMRON IA Global

 
Submit Enquiry

Back To
 
NT31(C) Main Page


Member Area

Find out information related to NT31(C).

Catalogs/Manuals

CAD Drawings

Replacement Info

 


Related Contents

FAQs

Selection Guide

RoHS Compliant Status

Select Country

View NT31(C) standards in your country.

Australia Philippines
India Singapore
Indonesia Thailand
Malaysia New Zealand

 

Product Information

Product Index :: Automation Systems :: Programmable Terminals :: NT Series (Basic HMI)

Standards Certification

NT31/NT31C Programmable Terminal

 

EN/IEC Standards

 

Model

CE Marking

Basic Requirements of Machinery Directive/Low-voltage Directive

Basic Requirements of EMC Directive

Applicable Standard No.

EMI Standard No.

EMS Standard No.

Certification Body

NT31-ST123(B)-(E)V3
NT31C-ST143(B)-(E)V3

Yes

Not Applicable

EN61131-2

EN61131-2

Self-declaration

 

We issue documentation ("EC Declaration of Conformity") providing details on the level of conformance. Contact your OMRON representative if required.

 

 

UL Certifications

 

Model

Standard No.

File No.

Marking

Listed/

Recognized

Category

NT31/31C

UL508

E95399

UL or cULus

Listed

NRAQ/NRAQ7

 

Note:

1. The above table lists series names. Ask your OMRON representative for details on specific model numbers.

2. Products that are certified for UL 1604 can be used in hazardous locations for Class I, Div. 2, Groups A, B, C, and D.


Description of Hazardous Locations:
[Class]
   Class I: Locations in which flammable gases or vapors may be present in the air in sufficient quantities to be explosive or ignitable.
   Class II: Locations in which combustible dust is present.
   Class III: Locations in which easily ignitable fibers or flyings are present
   but are not airborne in sufficient quantities to ignite.
[Division]
   Division 1: Locations in which explosive or ignitable material is normally present or is present at certain times.
   Division 2: Locations in which explosive or ignitable material is not normally present (but may accidentally exist).
[Group]
   Class I:
   Group A: Acetylene
   Group B: Combustible gas/vapor, example: hydrogen
   Group C: Combustible gas/vapor, example: ethylene
   Group D: Combustible gas/vapor, example: propane

 

 

CSA Certification

 

Model

Standard No.

File No.

NT31/31C

CSA C22.2 No.14

LR105257

 

 

LR Standards (UK Marine Standards)

 

Model

Environmental Category

ENV1 ENV2 ENV3 ENV4 ENV5 Remarks

NT31

 

     

*

 

* General Power distribution Zones
 

Note:

1. The above table lists series names. Ask your OMRON representative for details on specific model numbers.
2. NS-series PTs are certified for the bridge.
    When using an NS-series PT on the bridge, attach a noise filter and an electromagnetic shield.
  Use the TAH-06-683 from Cosel Co., Ltd., for the noise filter.
  Use the E09F-100 or E09R13502P from Seiwa Electric Mfg. Co., Ltd., for the electromagnetic shield.
  Refer to the product manuals for details.
3. Model certification has not been received for usage on the deck, in the bridge (except for NS-series PTs), or in locations subject to strong vibration.

 

 

NK Certification (Japanese Marine Standards)

 

Model

NT31/NT31C

 

Note:

1. The above table lists series names. Ask your OMRON representative for details on specific model numbers.
2. NS-series PTs are certified for the bridge.
  When using an NS-series PT on the bridge, attach a noise filter and an electromagnetic shield.
  Use the TAH-06-683 from Cosel Co., Ltd., for the noise filter.
  Use the E09F-100 or E09R13502P from Seiwa Electric Mfg. Co., Ltd., for the electromagnetic shield.
  Refer to the product manuals for details.
3. Model certification has not been received for usage on the deck, in the bridge (except for NS-series PTs), or in locations subject to strong vibration.

top