Most Compact Level Size |
Compact
|
|
104.5
mm |
|
Compact and versatile Safety
Laser
Scanner
|
Low
Power Consumption
|
|
5
W |
|
Power saving, low power
consumption
(3.75 W in standby mode) |
Compact size allows 3 m*
safety zone, 270° detection angle.
A safety zone up to 3 m and warning zones up
to 10 m can be set.
* The minimum object resolution is 50/70 mm.
Top
Integrated Management via Ethernet
Industry First
Industry's first Ethernet-compliant Safety Laser Scanner
allows the user
to check operating state and analyze the cause of an emergency stop via
LAN even in large-scale applications using multiple scanners.
* Multiple OS32Cs cannot be monitored
simultaneously.

Top
Replaceable Sensor, No Reprogramming Needed
No reprogramming needed, the configuration is stored in the I/O block.
Replacing a damaged sensor is fast and easy.

Top
Flexible Zone Configurations
Industry Best
For complex AGV applications, up to 70 combinations - each with one safety
zone and two warning zones - can be set. The two warning zones can be set
to support various purposes such as warning sound and speed control.

Simplified Wiring
OMRON STI's innovative I/O method requires fewer inputs when configuring
multiple zones. Only 4 inputs are required to select from 6 zone sets.
If all 8 inputs are used, up to 70 zone sets are available.
Top
Convenient and Easy-to-use Functions
Operating State Can Be Determined at a Glance
Eight sector indicators* show the direction of intrusion.
Front display shows operating state and error codes.

* US patent No. for individual sector
indicators: US 6,753,776 B2
Top
Reference
boundary monitoring function
The OS32C Safety Laser Scanner constantly monitors reference points and turns OFF the safety
outputs when a shift in its position is detected.
(Per international standard IEC 61496-3, area scanners used in
applications where the angle of approach exceeds +/- 30 degrees with
respect to the detection plane, must use RBM in the detection zone.)

Top
Easy configuration of complex
zones
The configuration of the safety zone and warning zones can be done in real
time using a PC. Configurations can also be created or modified offline.

Response time can be set from 80
ms to 680 ms
Response time adjustment can filter out erroneous detections (machine
stoppage) caused by pollutants in the environment.
Provides Safety Category 3 safety circuit without a dedicated
controller
Compliant to global safety standards:

Type 3 Safety Laser Scanner complies with
IEC61496-1/-3.
Top
Cable access options
To tailor the OS32C to your installation, two options are available for
the location of the power and Ethernet connections - cable access either
from the back or from the left side.
These can be selected according to the needs of AGV or facilities design.

Top
|