Product Information

Product Index :: Auto Identification Systems :: RFID Systems

Standards Certification

V600 Electromagnetic RFID System

 

EN/IEC Standards

 

Model

Applicable Unit

CE Marking

Basic Requirements of EMC Directive

Name Model

Applicable Standard No./

Application Standard No./

Certification Body/File No.

V600-CA Series

ID Controllers

V600-CA5D02

Yes

Not applicable

V600-CD Series

V600-CD1D-V3

V600-IDSC Series

V600-IDSC02
V600-IDSC04

C[]1W-V600

CJ1W-V600C11
CJ1W-V600C12
CS1W-V600C11
CS1W-V600C12

 

Model

Basic Requirements of EMC Directive

EMI Standard No.

EMS Standard No.

Testing Body

Applicable Period

V600-CA Series

EN61000-6-4

EN61000-6-2

UL Japan

Conformance completed

V600-CD Series

V600-IDSC Series

C[]1W-V600

 

Note: The power supply cable for the above products with DC power supplies must be less than 10 m.
For information on the R&TTE Directive for Read/Write Heads and Read/Write Antennas, refer to the Regulations Based on the Radio Wave Laws.

 

 

UL Certifications

 

Model

Standard No.

File No.

Marking

Listed/

Recognized

Category

Ratings/Remarks

CJ1W-V600C11
CJ1W-V600C12
CS1W-V600C11
CS1W-V600C12

UL508

E104818

cULus

Listed

NMTR/

NMTR7

 

V600-CA5D01

V600-CA5D02

UL508

E95399

cULus

Listed

NRAQ/

NRAQ7

Input: 24V DCV, 0.8A

V600-IDSC02

V600-IDSC04

UL508

E104818

cULus

Listed

NMTR/

NMTR7

Input: 24V DC, 50 W

 

The above models have a DC power supply. Be sure the following conditions are met.
Connect to one of the following circuits ((1) or (2)).

 

(1) Limited-voltage/current circuit conforming to UL508
A circuit that uses, as the power supply, the secondary wiring of an insulating transformer
Maximum voltage (no-load state): 30 Vrms (42.4 V peak) max.
Maximum current:

1) 8 A max. (including short-circuited state) or

2) The current is limited with a circuit-protection device (e.g., fuse) of the ratings shown in the following table:

 

No-load voltage (V peak)

Maximum current rating (A)

0 to 20

5.0

Greater than 20 V peak,

no greater than 30 V peak

100/Peak voltage value

 

(2) A Class 2 power supply unit conforming to UL1310 or circuit with maximum voltage of 30 Vrms (42.4 V peak) that uses, as the power supply, a Class 2 transformer to conforming UL1585

 

Note: Listing approvals

 

 

CSA Certification

 

Model

File No.

Ratings

V600-CA5D02

E95399

Input: 24V

 

 

FCC (USA Radio Law)

 








Model/Combination

FCC ID

V600-CH1D-PDI
V600-CH1D-V2
V600-CHUD

E4E6CYCIDV6000203

V600-H07

E4E6CYSIDV6000190

V600-H11

V600-H51

E4E6CYSIDV6000292

V600-H52

V600-HA51

V600-HS51
V600-HS61

V600-HAM42-DRT

V600-HS51
V600-HS61
V600-HS63
V600-HS67

E4E6CYSIDV6000190

V600-HAM81

V600-HS51
V600-HS61
V600-HS63
V600-HS67

V600-HAM91

V600-HAR81

V600-HAR91

V600-HAR92

 

 

IC Certification

 








                
Model IC ID

V600-CHUD

850J-V60CHUD

V600-H07

1814-K1214

V600-H11

850J-K1214

V600-H51

1814-K1211

V600-H52

V600-HAM42-DRT

V680-HS51
V680-HS52
V680-HS63
V680-HS65

850J-K1214

V600-HAM91
V600-HAM81

V600-HAR91
V600-HAR92
V600-HAR81

 

 

Korea Radio Wave Law

 



                





                

Model

Certification No.

V600-CH1D-V2

OMR-V60CHID

V600-CHUD

OMR-V60CHUD

V600-H07

OMR-V60-H07

V600-H11

OMR-V60-H11

V600-H51

OMR-V60-H51

V600-H52

OMR-V60-H52

V600-HA51

V600-HS51

OMR-V60HA51-HS51

V600-HA51

V600-HS61

OMR-V60HA51-HS61

V600-HAM42-DRT

V600-HS51

OMR-V60HAM42-HS51

V600-HS61

OMR-V60HAM42-HS61

V600-HS63

OMR-V60HAM42-HS63

V600-HS67

OMR-V60HAM42-HS67

V600-HAM81

V600-HS51

OMR-V60HAM81-HS51

V600-HS61

OMR-V60HAM81-HS61

V600-HS63

OMR-V60HAM81-HS63

V600-HS67

OMR-V60HAM81-HS67

V600-HAM91

V600-HS51

OMR-V60HAM91-HS51

V600-HS61

OMR-V60HAM91-HS61

V600-HS63

OMR-V60HAM91-HS63

V600-HS67

OMR-V60HAM91-HS67

V600-HAR81

V600-HS51

OMR-V60HAR81-HS51

V600-HS61

OMR-V60HAR81-HS61

V600-HS63

OMR-V60HAR81-HS63

V600-HS67

OMR-V60HAR81-HS67

V600-HAR91

V600-HS51

OMR-V60HAR91-HS51

V600-HS61

OMR-V60HAR91-HS61

V600-HS63

OMR-V60HAR91-HS63

V600-HS67

OMR-V60HAR91-HS67

V600-HAR92

V600-HS51

OMR-V60HAR92-HS51

V600-HS61

OMR-V60HAR92-HS61

V600-HS63

OMR-V60HAR92-HS63

V600-HS67

OMR-V60HAR92-HS67

 

 

China Radio Law: CMIIT Type Approval

 



                





                
Model/Combination ID

V600-CH1D-V2

2006DJ2077

V600-CHUD

2006DJ2074

V600-H11*

2006DJ0989

V600-H51 *

2011DJ3601

V600-H52 *

2011DJ3602

V600-HA51

V600-HS51

2011DJ3604

V600-HS61

2011DJ3603

V600-HAM81

V600-HS51

2011DJ3614

V600-HS61

2011DJ3607

V600-HS63

2011DJ3615

V600-HAM91

V600-HS51

2011DJ3610

V600-HS61

2011DJ3616

V600-HS63

2006DJ0994

V600-HAR91

V600-HS51

2011DJ3605

V600-HS61

2006DJ0995

V600-HS63

2006DJ0988

V600-HAR92

V600-HS51

2011DJ3617

V600-HS61

2006DJ0993

V600-HS63

2011DJ3611

V600-HAM42-DRT

V600-HS51

2006DJ2076

V600-HS61

2006DJ2078

V600-HS63

2006DJ2075

V600-HS63-2

2011DJ3613

* Models other than the V600-H11, V600-H51, and V600-H52, such as the V600-H11-R, V600-H11-W, V600-H52-W, and V600-H52-R, cannot be used in China because they are not included in Chinese radio wave legal certification.