Page top

Industrial Automation

Industrial Automation

G3S / G3SD

Solid State Relays

G3S / G3SD

Ultra-small Relay Breaks up to 1 A

Ratings

Input (Each models has 5-VDC, 12-VDC, and 24-VDC input versions.)

Rated voltage Operating voltage Must operate
voltage level
Must release
voltage level
Impedance
G3S-201PL
G3S-201PL-PD
G3SD-Z01P
G3SD-Z01P-PD
5 VDC 4 to 6 VDC 4 VDC max. 1 VDC min. 450 Ω ±20% 630 Ω ±20%
12 VDC 9.6 to 14.4 VDC 9.6 VDC max. 1.1 kΩ ±20% 1.5 kΩ ±20%
24 VDC 19.2 to 28.8 VDC 19.2 VDC max. 2.2 kΩ ±20% 2.8 kΩ ±20%

Output

Model Item Rated load voltage Rated load voltage range Load current Inrush current
G3S-201PL 100 to 240 VAC 75 to 264 VAC 0.1 to 1 A * 15 A
(60 Hz, 1 cycle)
G3S-201PL-PD 0.1 to 1.2 A *
G3SD-Z01P 4 to 24 VDC 3 to 26 VDC 0.01 to 1 A * 3 A (10 ms)
G3SD-Z01P-PD 0.01 to 1.1 A *

* The applicable output load current varies depending on the ambient temperature.
  Refer to reference data the "Load Current vs. Ambient Temperature" rating characteristic for details.

Characteristics

Model G3S-201PL, G3S-201PL-PD G3SD-Z01P, G3SD-Z01P-PD
Operate time 1 ms max. 1 ms max.
Release time 1/2 of load power source cycle + 1 ms max. 1 ms max.
Output ON voltage drop 1.6 V (RMS) max. 1.5 V max.
Leakage current 2 mA (at 200 VAC) 0.1 mA max. (at 26 VDC)
Insulation resistance 100 MΩ min. (at 500 VDC)
Dielectric strength 2,500 VAC, 50/60 Hz for 1 min between input and output
Vibration resistance 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Shock resistance 1,000 m/s2
Storage temperature - 30°C to 100°C (with no icing or condensation)
Ambient operating temperature - 30°C to 80°C (with no icing or condensation)
Ambient operating humidity 45% to 85% RH
Weight Approx. 13 g