Page top

Industrial Automation

Industrial Automation

Discontinued On Aug. 2022

3G3RX-V1

High-function General-purpose Inverters

3G3RX-V1

Versatile for a Wide Range of Applications

* Information in this page is a reference that you created on the basis of information in the product catalog before the end of production, may be different from the current situation, such as goods for / supported standards options / price / features of the product. Before using, please check the compatibility and safety system.

RX series V1 type Inverter Models

Rated voltage Enclosure ratings Max. applicable motor capacity Model
CT: Heavy load VT: Light load
3-phase 200 VAC IP20 0.4 kW 0.75 kW 3G3RX-A2004-V1
0.75 kW 1.5 kW 3G3RX-A2007-V1
1.5 kW 2.2 kW 3G3RX-A2015-V1
2.2 kW 3.7 kW 3G3RX-A2022-V1
3.7 kW 5.5 kW 3G3RX-A2037-V1
5.5 kW 7.5 kW 3G3RX-A2055-V1
7.5 kW 11 kW 3G3RX-A2075-V1
11 kW 15 kW 3G3RX-A2110-V1
15 kW 18.5 kW 3G3RX-A2150-V1
18.5 kW 22 kW 3G3RX-A2185-V1
22 kW 30 kW 3G3RX-A2220-V1
30 kW 37 kW 3G3RX-A2300-V1
37 kW 45 kW 3G3RX-A2370-V1
45 kW 55 kW 3G3RX-A2450-V1
55 kW 75 kW 3G3RX-A2550-V1
3-phase 400 VAC 0.4 kW 0.75 kW 3G3RX-A4004-V1
0.75 kW 1.5 kW 3G3RX-A4007-V1
1.5 kW 2.2 kW 3G3RX-A4015-V1
2.2 kW 3.7 kW 3G3RX-A4022-V1
3.7 kW 5.5 kW 3G3RX-A4037-V1
5.5 kW 7.5 kW 3G3RX-A4055-V1
7.5 kW 11 kW 3G3RX-A4075-V1
11 kW 15 kW 3G3RX-A4110-V1
15 kW 18.5 kW 3G3RX-A4150-V1
18.5 kW 22 kW 3G3RX-A4185-V1
22 kW 30 kW 3G3RX-A4220-V1
30 kW 37 kW 3G3RX-A4300-V1
37 kW 45 kW 3G3RX-A4370-V1
45 kW 55 kW 3G3RX-A4450-V1
55 kW 75 kW 3G3RX-A4550-V1
IP00 75 kW 90 kW 3G3RX-B4750-V1
90 kW 110 kW 3G3RX-B4900-V1
110 kW 132 kW 3G3RX-B411K-V1
132 kW 160 kW 3G3RX-B413K-V1

Communication Unit

Name Model
EtherCAT Communication Unit 3G3AX-RX-ECT
CompoNet™ Communication Unit 3G3AX-RX-CRT-E
DeviceNet™ Communication Unit 3G3AX-RX-DRT-E

Related Options

Name Specifications Model
Regenerative
Braking Units
3-phase 200 VAC General purpose with Braking resistor 3G3AX-RBU21
High Regeneration purpose with Braking resistor 3G3AX-RBU22
General purpose for 30 kW * 3G3AX-RBU23
General purpose for 55 kW * 3G3AX-RBU24
3-phase 400 VAC General purpose with Braking resistor 3G3AX-RBU41
General purpose for 30 kW * 3G3AX-RBU42
General purpose for 55 kW * 3G3AX-RBU43
Braking Resistor Compact type Resistor 120 W, 180 W 3G3AX-RBA1201
Resistor 120 W, 100 W 3G3AX-RBA1202
Resistor 120 W, 50 W 3G3AX-RBA1203
Resistor 120 W, 35 W 3G3AX-RBA1204
Standard type Resistor 200 W, 180 W 3G3AX-RBB2001
Resistor 200 W, 100 W 3G3AX-RBB2002
Resistor 300 W, 50 W 3G3AX-RBB3001
Resistor 400 W, 35 W 3G3AX-RBB4001
Medium capacity type Resistor 400 W, 50 W 3G3AX-RBC4001
Resistor 600 W, 35 W 3G3AX-RBC6001
Resistor 1200 W, 17 W 3G3AX-RBC12001

* The braking resistor is optionally required.

Regenerative Braking Unit and Braking Resistor Combination

Select the combination of the regenerative braking unit(s) and the braking resistor(s) as follows, according to your inverter. If the usage rate exceeds 10% ED, or if you need a torque larger than the approximate braking torque, you need to follow the instruction provided in Braking Resistor Selection.

  • Inverter:
    Select the model of your inverter. However, the table below assumes that your inverter is used in the heavy load mode and connected to a single motor with the same capacity. Therefore, in the light load mode, a motor with the same capacity means a motor that is one size larger in capacity than the inverter and the converted braking torque decreases accordingly.
  • Operating conditions:
    Show the torque during deceleration and the deceleration time (in % ED) calculated as a percentage of the cycle time for 1 cycle of operation including the stop time.
  • Braking unit/Breaking resistor:
    Show the required the model and number of units.
  • Connection form:
    Show the configuration of the regenerative braking unit(s) and braking resistor(s) illustrated in the connection form table below.
  • Restrictions:
    Show the maximum deceleration time allowable for the combination shown here and the minimum resistance that can be connected to the inverter's built-in regenerative braking circuit or external regenerative braking unit(s).

Inverter Operating
conditions
Braking unit Braking resistor Con-
nec-
tion
form
Restrictions
Volt-
age
class
Max.
appli-
cable
motor
ca-
pacity
(kW)
Model %ED
(%)
Ap-
proxi-
mate
braking
torque
(%)
Model Num-
ber
of
units
Model Num-
ber
of
units
Allowa-
ble
contin-
uous
braking
time
(s)
Min.
con-
nect-
able
resis-
tance
(Ω)
200-V
Class
0.4 3G3RX-
A2004-V1
0.03 220% Built-in
Inverter
--- 3G3AX-RBA1201 1 1 20 50
0.1 220% --- 3G3AX-RBB2001 1 1 30 50
0.75 3G3RX-
A2007-V1
0.03 120% Built-in
Inverter
--- 3G3AX-RBA1201 1 1 20 50
0.1 120% --- 3G3AX-RBB2001 1 1 30 50
1.5 3G3RX-
A2015-V1
0.025 110% Built-in
Inverter
--- 3G3AX-RBA1202 1 1 12 35
0.1 215% --- 3G3AX-RBC4001 1 1 10 35
2.2 3G3RX-
A2022-V1
0.03 150% Built-in
Inverter
--- 3G3AX-RBB3001 1 1 30 35
0.1 150% --- 3G3AX-RBC4001 1 1 10 35
3.7 3G3RX-
A2037-V1
0.03 125% Built-in
Inverter
--- 3G3AX-RBB4001 1 1 20 35
0.1 125% --- 3G3AX-RBC6001 1 1 10 35
5.5 3G3RX-
A2055-V1
0.03 120% Built-in
Inverter
--- 3G3AX-RBB3001 2 2 30 16
0.1 120% --- 3G3AX-RBC4001 2 2 10 16
7.5 3G3RX-
A2075-V1
0.03 125% Built-in
Inverter
--- 3G3AX-RBB4001 2 2 20 10
0.1 125% --- 3G3AX-RBC6001 2 2 10 10
11 3G3RX-
A2110-V1
0.03 125% Built-in
Inverter
--- 3G3AX-RBB4001 3 4 20 10
0.1 125% --- 3G3AX-RBC6001 3 4 10 10
15 3G3RX-
A2150-V1
0.03 130% Built-in
Inverter
--- 3G3AX-RBC12001 2 2 10 7.5
0.1 130% --- 3G3AX-RBC12001 2 2 10 7.5
18.5 3G3RX-
A2185-V1
0.03 105% Built-in
Inverter
--- 3G3AX-RBC12001 2 2 10 7.5
0.1 105% --- 3G3AX-RBC12001 2 2 10 7.5
22 3G3RX-
A2220-V1
0.03 130% Built-in
Inverter
--- 3G3AX-RBC12001 3 4 10 5
0.1 130% --- 3G3AX-RBC12001 3 4 10 5
30 3G3RX-
A2300-V1
0.03 160% 3G3AX-
RBU24
1 3G3AX-RBC12001 5 11 10 2
0.1 160% 3G3AX-
RBU24
1 3G3AX-RBC12001 5 11 10 2
37 3G3RX-
A2370-V1
0.03 130% 3G3AX-
RBU24
1 3G3AX-RBC12001 5 11 10 2
0.1 130% 3G3AX-
RBU24
1 3G3AX-RBC12001 5 11 10 2
45 3G3RX-
A2450-V1
0.03 130% 3G3AX-
RBU24
1 3G3AX-RBC12001 6 12 10 2
0.1 130% 3G3AX-
RBU24
1 3G3AX-RBC12001 6 12 10 2
55 3G3RX-
A2550-V1
0.03 120% 3G3AX-
RBU24
1 3G3AX-RBC12001 7 13 10 2
0.1 120% 3G3AX-
RBU24
1 3G3AX-RBC12001 7 13 10 2
400-V
Class
0.4 3G3RX-
A4004-V1
0.03 220% Built-in
Inverter
--- 3G3AX-RBA1201 2 3 20 100
0.1 220% --- 3G3AX-RBB2001 2 3 30 100
0.75 3G3RX-
A4007-V1
0.03 220% Built-in
Inverter
--- 3G3AX-RBA1201 2 3 20 100
0.1 220% --- 3G3AX-RBB2001 2 3 30 100
1.5 3G3RX-
A4015-V1
0.03 120% Built-in
Inverter
--- 3G3AX-RBA1201 2 3 20 100
0.1 120% --- 3G3AX-RBB2001 2 3 30 100
2.2 3G3RX-
A4022-V1
0.025 150% Built-in
Inverter
--- 3G3AX-RBA1202 2 3 12 100
0.1 220% --- 3G3AX-RBC4001 2 3 10 100
3.7 3G3RX-
A4037-V1
0.03 175% Built-in
Inverter
--- 3G3AX-RBB3001 2 3 30 70
0.1 175% --- 3G3AX-RBC4001 2 3 10 70
5.5 3G3RX-
A4055-V1
0.03 120% Built-in
Inverter
--- 3G3AX-RBB3001 2 3 30 70
0.1 120% --- 3G3AX-RBC4001 2 3 10 70
7.5 3G3RX-
A4075-V1
0.03 125% Built-in
Inverter
--- 3G3AX-RBB4001 2 3 20 35
0.1 125% --- 3G3AX-RBC6001 2 3 10 35
11 3G3RX-
A4110-V1
0.03 120% Built-in
Inverter
--- 3G3AX-RBB3001 4 5 30 35
0.1 120% --- 3G3AX-RBC4001 4 5 10 35
15 3G3RX-
A4150-V1
0.03 125% Built-in
Inverter
--- 3G3AX-RBB4001 4 5 20 24
0.1 125% --- 3G3AX-RBC6001 4 5 10 24
18.5 3G3RX-
A4185-V1
0.03 140% Built-in
Inverter
--- 3G3AX-RBB3001 8 6 30 24
0.1 140% --- 3G3AX-RBC4001 8 6 10 24
22 3G3RX-
A4220-V1
0.03 120% Built-in
Inverter
--- 3G3AX-RBB3001 8 6 30 20
0.1 120% --- 3G3AX-RBC4001 8 6 10 20
30 3G3RX-
A4300-V1
0.03 130% 3G3AX-
RBU42
1 3G3AX-RBC12001 4 8 10 10
0.1 130% 3G3AX-
RBU42
1 3G3AX-RBC12001 4 8 10 10
37 3G3RX-
A4370-V1
0.03 155% 3G3AX-
RBU43
1 3G3AX-RBC12001 6 9 10 6
0.1 155% 3G3AX-
RBU43
1 3G3AX-RBC12001 6 9 10 6
45 3G3RX-
A4450-V1
0.03 130% 3G3AX-
RBU43
1 3G3AX-RBC12001 6 9 10 6
0.1 130% 3G3AX-
RBU43
1 3G3AX-RBC12001 6 9 10 6
55 3G3RX-
A4550-V1
0.03 140% 3G3AX-
RBU43
1 3G3AX-RBC12001 8 10 10 6
0.1 140% 3G3AX-
RBU43
1 3G3AX-RBC12001 8 10 10 6
75 3G3RX-
A4750-V1
0.03 130% 3G3AX-
RBU43
1 3G3AX-RBC12001 10 14 10 6
0.1 130% 3G3AX-
RBU43
1 3G3AX-RBC12001 10 14 10 6
90 3G3RX-
A4900-V1
0.03 105% 3G3AX-
RBU43
1 3G3AX-RBC12001 10 14 10 6
0.1 105% 3G3AX-
RBU43
1 3G3AX-RBC12001 10 14 10 6
110 3G3RX-
A411K-V1
0.03 105% 3G3AX-
RBU43
2 3G3AX-RBC12001 12 15 10 6
0.1 105% 3G3AX-
RBU43
2 3G3AX-RBC12001 12 15 10 6
132 3G3RX-
A413K-V1
0.03 115% 3G3AX-
RBU43
2 3G3AX-RBC12001 16 16 10 6
0.1 115% 3G3AX-
RBU43
2 3G3AX-RBC12001 16 16 10 6

Name Model
Radio Noise Filter 3G3AX-ZCL2
3G3AX-ZCL1

Name Specifications of Inverter Model
Voltage class CT: Heavy load (kW) VT: Light load (kW)
Input Noise Filter 3-phase 200 VAC 0.4 to 0.75 0.75 3G3AX-NFI21
1.5 1.5 3G3AX-NFI22
2.2, 3.7 2.2, 3.7 3G3AX-NFI23
5.5 5.5 3G3AX-NFI24
7.5 7.5 3G3AX-NFI25
11 11 3G3AX-NFI26
15 15 3G3AX-NFI27
18.5 18.5 3G3AX-NFI28
22, 30 22, 30 3G3AX-NFI29
37 37 3G3AX-NFI2A
45 45 3G3AX-NFI2B
55 55 3G3AX-NFI2C
3-phase 400 VAC 0.4 to 2.2 0.75 to 2.2 3G3AX-NFI41
3.7 3.7 3G3AX-NFI42
5.5, 7.5 5.5, 7.5 3G3AX-NFI43
11 11 3G3AX-NFI44
15 15 3G3AX-NFI45
18.5 18.5 3G3AX-NFI46
22 22 3G3AX-NFI47
30 30 3G3AX-NFI48
37 37 3G3AX-NFI49
45, 55 45, 55 3G3AX-NFI4A
EMC Noise Filter * 3-phase 200 VAC 0.4 to 7.5 0.75 3G3AX-EFI41
1.5 1.5 3G3AX-EFI42
2.2, 3.7 2.2, 3.7 3G3AX-EFI43
5.5 5.5 3G3AX-EFI44
7.5 7.5 3G3AX-EFI45
11 11 3G3AX-EFI47
15 15 3G3AX-EFI48
18.5 18.5 3G3AX-EFI49
22, 30 22, 30 3G3AX-EFI4A
37 37 3G3AX-EFI4B
3-phase 400 VAC 0.4 to 22 0.75 to 2.2 3G3AX-EFI41
3.7 3.7 3G3AX-EFI42
5.5, 7.5 5.5, 7.5 3G3AX-EFI43
11 11 3G3AX-EFI44
15 15 3G3AX-EFI45
18.5 18.5 3G3AX-EFI46
22 22 3G3AX-EFI47
30 30 3G3AX-EFI48
37 37 3G3AX-EFI49
45, 55 45, 55 3G3AX-EFI4A
75, 90 75, 90 3G3AX-EFI4B
Output Noise Filter 3-phase 200 VAC/
3-phase 400 VAC
Applicable motor
200 V class: 0.4 to 0.75
400 V class: 0.4 to 2.2
Applicable motor
200 V class: 0.75
400 V class: 0.75 to 2.2
3G3AX-NFO01
Applicable motor
200 V class: 1.5, 2.2
400 V class: 3.7
Applicable motor
200 V class: 1.5, 2.2
400 V class: 3.7
3G3AX-NFO02
Applicable motor
200 V class: 3.7, 5.5
400 V class: 5.5 to 11
Applicable motor
200 V class: 3.7, 5.5
400 V class: 5.5 to 11
3G3AX-NFO03
Applicable motor
200 V class: 7.5, 11
400 V class: 15 to 22
Applicable motor
200 V class: 7.5, 11
400 V class: 15 to 22
3G3AX-NFO04
Applicable motor
200 V class: 15
400 V class: 30, 37
Applicable motor
200 V class: 15
400 V class: 30, 37
3G3AX-NFO05
Applicable motor
200 V class: 18.5, 22
400 V class: 45
Applicable motor
200 V class: 18.5, 22
400 V class: 45
3G3AX-NFO06
Applicable motor
200 V class: 30, 37
400 V class: 55, 75
Applicable motor
200 V class: 30, 37
400 V class: 55, 75
3G3AX-NFO07
DC Reactor 3-phase 200 VAC 0.4 --- 3G3AX-DL2004
0.75 0.75 3G3AX-DL2007
1.5 1.5 3G3AX-DL2015
2.2 2.2 3G3AX-DL2022
3.7 3.7 3G3AX-DL2037
5.5 5.5 3G3AX-DL2055
7.5 7.5 3G3AX-DL2075
11 11 3G3AX-DL2110
15 15 3G3AX-DL2150
18.5, 22 18.5, 22 3G3AX-DL2220
30 30 3G3AX-DL2300
37 37 3G3AX-DL2370
45 45 3G3AX-DL2450
55 55 3G3AX-DL2550
3-phase 400 VAC 0.4 --- 3G3AX-DL4004
0.75 0.75 3G3AX-DL4007
1.5 1.5 3G3AX-DL4015
2.2 2.2 3G3AX-DL4022
3.7 3.7 3G3AX-DL4037
5.5 5.5 3G3AX-DL4055
7.5 7.5 3G3AX-DL4075
11 11 3G3AX-DL4110
15 15 3G3AX-DL4150
18.5, 22 18.5, 22 3G3AX-DL4220
30 30 3G3AX-DL4300
37 37 3G3AX-DL4370
45 45 3G3AX-DL4450
55 55 3G3AX-DL4550
AC Reactor 3-phase 200 VAC 0.4 to 1.5 0.75 to 1.5 3G3AX-AL2025
2,2, 3.7 2.2, 3.7 3G3AX-AL2055
5.5, 7.5 5.5, 7.5 3G3AX-AL2110
11, 15 11, 15 3G3AX-AL2220
18.5, 22 18.5, 22 3G3AX-AL2330
30, 37 30, 37 3G3AX-AL2500
45, 55 45, 55 3G3AX-AL2750
3-phase 400 VAC 0.4 to 1.5 0.75 to 1.5 3G3AX-AL4025
2.2, 3.7 2.2, 3.7 3G3AX-AL4055
5.5, 7.5 5.5, 7.5 3G3AX-AL4110
11, 15 11, 15 3G3AX-AL4220
18.5, 22 18.5, 22 3G3AX-AL4330
30, 37 30, 37 3G3AX-AL4500
45, 55 45, 55 3G3AX-AL4750

* Although an EMC Noise Filter is built into the RX, it may be necessary to provide another EMC Noise Filter when the
  cable between the Motor and the Inverter is long.

Name Specifications Model
PG Board For Position or Frequency Control 3G3AX-PG01
Digital Operator --- 3G3AX-OP01
Digital Operator Connecting Cable Cable Length 1 m 3G3AX-OPCN1
Cable Length 3 m 3G3AX-OPCN3

Recommended EtherCAT Communications Cables

Use Straight STP (shielded twisted-pair) cable of category 5 or higher with double shielding (braiding and aluminum foil tape) for EtherCAT.

Cable with Connectors

Item Appearance Recommended
manufacturer
Cable
length
(m)
Model
Cable with Connectors on Both Ends
(RJ45/RJ45)
Standard RJ45 plugs type *1
Wire Gauge and Number of Pairs:
AWG26, 4-pair cable
Cable Sheath material: LSZH *2
Cable color: Yellow *3
3146_lu_8_1 OMRON 0.3 XS6W-6LSZH8SS30CM-Y
0.5 XS6W-6LSZH8SS50CM-Y
1 XS6W-6LSZH8SS100CM-Y
2 XS6W-6LSZH8SS200CM-Y
3 XS6W-6LSZH8SS300CM-Y
5 XS6W-6LSZH8SS500CM-Y
Cable with Connectors on Both Ends
(RJ45/RJ45)
Rugged RJ45 plugs type *1
Wire Gauge and Number of Pairs:
AWG22, 2-pair cable
Cable color: Light blue
3146_lu_8_2 OMRON 0.3 XS5W-T421-AMD-K
0.5 XS5W-T421-BMD-K
1 XS5W-T421-CMD-K
2 XS5W-T421-DMD-K
5 XS5W-T421-GMD-K
10 XS5W-T421-JMD-K
Cable with Connectors on Both Ends
(M12 Straight/RJ45)
Shield Strengthening Connector cable *4
M12/Smartclick Connectors
Rugged RJ45 plugs type
Wire Gauge and Number of Pairs:
AWG22, 2-pair cable
Cable color: Black
3146_lu_8_4 OMRON 0.5 XS5W-T421-BMC-SS
1 XS5W-T421-CMC-SS
2 XS5W-T421-DMC-SS
3 XS5W-T421-EMC-SS
5 XS5W-T421-GMC-SS
10 XS5W-T421-JMC-SS

*1 Standard type cables length 0.2, 0.3, 0.5, 1, 1.5, 2, 3, 5, 7.5, 10, 15 and 20 m are available.
       Rugged type cables length 0.3, 0.5, 1, 2, 3, 5, 10 and 15 m are available.
       For details, refer to Cat.No.G019.
*2 The lineup features Low Smoke Zero Halogen cables for in-cabinet use and PUR cables for out-of-cabinet use.
      Although the LSZH cable is single shielded, its communications and noise characteristics meet the standards.
*3 Cables colors are available in blue, yellow, or Green.
*4 For details, contact your OMRON representative.

Cables/Connectors
Wire Gauge and Number of Pairs: AWG24, 4-pair Cable

Item Appearance Recommended manufacturer Model
Cables --- Hitachi Metals, Ltd. NETSTAR-C5E SAB 0.5 x 4P CP *
--- Kuramo Electric Co. KETH-SB *
RJ45 Connectors --- Panduit Corporation MPS588-C *

* We recommend you to use above cable and connector together.

Wire Gauge and Number of Pairs: AWG22, 2-pair Cable

Item Appearance Recommended manufacturer Model
Cables --- Kuramo Electric Co. KETH-PSB-OMR *
--- JMACS Japan Co., Ltd. PNET/B *
RJ45 Assembly Connector 3146_lu_10_1 OMRON XS6G-T421-1 *

* We recommend you to use above cable and connector together.

Software

How to Select Required Support Software for Your Controller

The required Support Software depends on the Controller to connect. Please check the following table when purchasing the Support Software.

Item Omron PLC System Omron Machine Automation Controller System
Controller CS, CJ, CP, and other series NJ/NX-series
Inverter Inverter RX-series V1 tyep
Inverter RX-series V1 tyep with CompoNet™
Communication Unit
Inverter RX-series V1 tyep with DeviceNet™
Communication Unit
Inverter RX-series V1 tyep with EtherCAT Communication
Unit
Software FA Integrated Tool Package CX-One
(CX-Drive: Version 2.72 or higher)
Automation Software Sysmac Studio (Version 1.03 or higher)

FA Integrated Tool Package CX-One

Product name Specifications Model
Number of
licenses
Media
FA Integrated
Tool Package
CX-One
Ver.4.[]
The CX-One is a comprehensive software package
that integrates Support Software for OMRON PLCs
and components.
CX-One runs on the following OS.
Windows 7 (32-bit/64-bit version) /
Windows 8 (32-bit/64-bit version) /
Windows 8.1 (32-bit/64-bit version) /
Windows 10 (32-bit/64-bit version)

CX-One Version 4.[] includes CX-Drive Ver.2.[].
For details, refer to the CX-One catalog (Cat. No. R134)
1 license
*
DVD CXONE-AL01D-V4

* Multi licenses (3, 10, 30, or 50 licenses) and DVD media without licenses are also available for the CX-One.

Automation Software Sysmac Studio

Please purchase a DVD and required number of licenses the first time you purchase the Sysmac Studio. DVDs and licenses are available individually. Each model of licenses does not include any DVD.

Product
name
Specifications Model
Number of
licenses
Media
Sysmac
Studio
Standard
Edition
Ver.1.[][]
The Sysmac Studio is the software that provides an
integrated environment for setting, programming,
debugging and maintenance of machine automation
controllers including the NJ/NX-series CPU Units,
NY-series Industrial PC, EtherCAT Slave, and the HMI.

Sysmac Studio runs on the following OS. *1
Windows 7 (32-bit/64-bit version) / Windows 8 (32-bit/64-bit
version)/Windows 8.1 (32-bit/64-bit version)/ Windows 10
(32-bit/64-bit version)/Windows 11 (64-bit version)

The Sysmac Studio Standard Edition DVD includes Support
Software to set up EtherNet/IP Units, DeviceNetTM slaves,
Serial Communications Units, and Support Software for
creating screens on HMIs (CX-Designer).
For details, refer to your OMRON website.
-
(Media
only)
Sysmac
Studio
(32 bit)
DVD
SYSMAC-SE200D
-
(Media
only)
Sysmac
Studio
(64 bit)
DVD
SYSMAC-SE200D-64
1 license
*2
--- SYSMAC-SE201L

*1 Model "SYSMAC-SE200D-64" runs on Windows 10 (64 bit) or higher.
*2 Multi licenses are available for the Sysmac Studio (3, 10, 30, or 50 licenses).

Communications Cable

Name Specifications Model