Page top

Industrial Automation

Industrial Automation

E6F-C

Incremental 60-mm-dia. Rotary Encoder

E6F-C

Rugged Rotary Encoder

Model E6F-CWZ5G E6F-CWZ5C
Power supply voltage 12 VDC -10% to 24 VDC +15%, ripple (p-p): 5% max.
Current consumption *1 100 mA max.
Resolution
(pulses/rotation)
100, 200, 360, 500, 600, 1,000 1,000
Output configuration Complementary outputs *2 NPN open-collector output
Output capacity Output voltage:
VH = Vcc -3 V min. (Io = 30 mA),
VL = 2 V max. (Io = -30 mA)
Output current: ±30 mA
Applied voltage: 30 VDC max.
Sink current: 35 mA max.
Residual voltage: 0.4 V max.
(at sink current of 35 mA)
Maximum response
frequency
83 kHz
Phase difference between
outputs
90°± 45° between A and B (1/4 T ± 1/8 T)
Rise and fall times of
output
1 μs max. (Cable length: 2 m, Output
current: 30 mA)
1 μs max. (Cable length: 2 m, Control
output voltage: 5 V, Load resistance: 1 kΩ)
Starting torque 10 mNm max. at room temperature, 15 mNm max. at low temperature
Moment of inertia 3 ×10-6 kgm2 max.; 1.5 × 10-6 kgm2 max. at 600 P/R max.
Shaft loading Radial 120 N
Thrust 50 N
Maximum permissible speed 5,000 r/min
Protection circuits Power supply reverse polarity protection, Output load short-circuit protection
Ambient temperature range Operating: -10 to 70°C (with no icing), Storage: -25 to 85°C (with no icing)
Ambient humidity range Operating/Storage: 35% to 85% (with no condensation)
Insulation resistance 20 MΩ min. (at 500 VDC) between current-carrying parts and case
Dielectric strength 500 VAC, 50/60 Hz for 1 min between current-carrying parts and case
Vibration resistance Destruction: 10 to 500 Hz, 150 m/s2 or 2-mm double amplitude for 11 min 3 times each
in X, Y, and Z directions
Shock resistance Destruction: 1,000 m/s2 3 times each in X, Y, and Z directions
Degree of protection IEC 60529 IP65, in-house standards: oilproof
Connection method Pre-wired Models (Standard cable length: 2 m)
Material Case: Zinc alloy, Main unit: Aluminum, Shaft: SUS420J2
Weight (packed state) Approx. 400 g
Accessories Instruction manual
Note: Coupling, mounting bracket and hex-head spanner are sold separately.

*1. An inrush current of approximately 9 A will flow for approximately 5 μs when the power is turned ON.
*2. Complementary Outputs
       The complementary output has two output transistors (NPN and PNP) as shown at the right. These two output
       transistors alternately turn ON and OFF depending on the high or low output signal. When using them, pull up to the
       positive power supply voltage level or pull down to 0 V. The complementary output allows flow-in or flow-out of the
      output current and thus the rising and falling speeds of signals are fast. This allows a long cable distance. They can
      be connected to open-collector input devices (NPN, PNP).

E6F-C Specifications 2