Page top

Industrial Automation

Industrial Automation

E5C2

Temperature Controller

E5C2

DIN-sized (48 x 48 mm) Temperature Controller with Analog Setting

Temperature Controllers

Input Thermocouple
K (CA)
Chromel vs. alumel
Standard scale (°C) 0 to
200
0 to
300
0 to
400
0 to
600
0 to
800
0 to
1,000
0 to
1,200
Setting
method
Indication
method
Control
mode
Output Minimum scale
division (°C)
5 10 10 20 20 25 25
Analog
setting
No
indication
ON/OFF Relay Model E5C2-R20K
Propor-
tional (P)
Relay Model E5C2-R40K ---

Input Thermocouple
J (IC)
Iron vs. constantan
Standard scale (°C) 0 to 200 0 to 300 0 to 400
Setting method Indication method Control mode Output Minimum scale
division (°C)
5 10 10
Analog setting No indication ON/OFF Relay Model E5C2-R20J
Proportional (P) Relay Model ---

Input Resistance Thermometer
Platinum resistance thermometer
Pt100
Standard scale (°C) -50
to
50
-20
to
80
0
to
50
0
to
100
0
to
200
0
to
300
0
to
400
Setting
method
Indication
method
Control mode Output Minimum scale
division (°C)
2 2 1 2 5 10 10
Analog
setting
No
indication
ON/OFF Relay Model E5C2-R20P-D
Proportional (P) Relay Model ---

Input Thermistor
Thermistor (replaceable element)
Standard scale (°C) Themistor nominal resistance
6 kΩ
(0°C)
6 kΩ
(0°C)
30 kΩ
(0°C)
550 Ω
(200°C)
4 kΩ
(200°C)
-50
to 50
0 to
100
50 to
150
100 to
200
150 to
300
Setting
method
Indication
method
Control mode Output Minimum scale
division (°C)
2 2 2 2 2
Analog
setting
No
indication
ON/OFF Relay Model E5C2-R20G
Proportional (P) Relay Model ---

Note: When placing an order, specify the temperature range in addition to the model number.

Standard Models

Indication method No indication
Control mode ON/OFF Proportional (P)
Output Relay
Input/standard
scale (°C)
Thermocouple K (CA)
Chromel vs. alumel
0 to 200 E5C2-R20K E5C2-R40K
0 to 300 E5C2-R20K E5C2-R40K
0 to 400 E5C2-R20K E5C2-R40K
0 to 600 E5C2-R20K E5C2-R40K
0 to 800 E5C2-R20K E5C2-R40K
0 to 1,000 E5C2-R20K ---
0 to 1,200 E5C2-R20K ---
J (IC)
Iron vs. constantan
0 to 200 E5C2-R20J ---
0 to 300 E5C2-R20J ---
0 to 400 E5C2-R20J ---
Resistance
Thermometer
Platinum resistance
thermometer Pt100
-50 to 50 E5C2-R20P-D ---
-20 to 80 E5C2-R20P-D ---
0 to 50 E5C2-R20P-D ---
0 to 100 E5C2-R20P-D ---
0 to 200 E5C2-R20P-D ---
0 to 300 E5C2-R20P-D ---
0 to 400 E5C2-R20P-D ---
Thermistor THE
(replaceable element)
-50 to 50 E5C2-R20G ---
0 to 100 E5C2-R20G ---
50 to 150 E5C2-R20G ---
100 to 200 E5C2-R20G ---
150 to 300 E5C2-R20G ---

Accessories (Order Separately)

Sockets

Name Model
Front Connecting Socket P2CF-08
Back Connecting Socket P3G-08
Front Connecting Socket with Finger Protection P2CF-08-E
Protective Cover (for finger protection) Y92A-48G

Protective Cover

Type Model
Hard Protective Cover Y92A-48B