SYSMAC CS-series Controller Link Units
last update: July 8, 2024
Unit
clas- sifica- tion |
Product
name |
Specifications | No. of
unit numbers allocated |
Current
consump- tion (A) |
Model | Stand-
ards |
||||
---|---|---|---|---|---|---|---|---|---|---|
Commu-
nications cable |
Commu-
nications type |
Duplex
support |
Max. Units
mountable per CPU Unit |
5 V
DC |
26 V
DC |
|||||
CS1
CPU Bus Unit |
Controller
Link Unit ![]() |
Wired
shielded twisted- pair cable *1 |
Data links
and message service |
No | 8 | 1 | 0.33 | - | CS1W-CLK23 | UC1,
N, L, CE |
Controller
Link Unit ![]() |
Optical
ring H-PCF cable *2 |
Yes. Unit
duplexing and cable loop back are supported. |
Non-duplex:
8, Duplex: 11 (6 Units comprising 3 sets of Duplex Units + 5 Non-duplex Units) |
1 | 0.52 | - | CS1W-CLK13 | |||
Controller
Link Unit ![]() |
Optical
ring GI cable *3 |
1 | 0.65 | - | CS1W-CLK53 |
The Optical Fiber Cable Bracket is included in CS1W-CLK13 and CS1W-CLK53.
Product name | Specifications | Accessories | Model | Stand-
ards |
|
---|---|---|---|---|---|
Communica-
tions cable |
Communica-
tions type |
||||
Controller Link
Support Board for PCI Bus ![]() |
Wired shielded
twisted-pair cable |
Data links
and message service |
• CD-ROM × 1 *
• INSTALLATION GUIDE (W467) × 1 • Communications connector × 1 |
3G8F7-CLK23-E | CE, KC |
H-PCF optical
model |
• CD-ROM × 1 *
• INSTALLATION GUIDE (W467) × 1 • Optical Fiber Cable Bracket × 1 • Power supply connector × 1 |
3G8F7-CLK13-E | CE | ||
GI optical model | 3G8F7-CLK53-E |
Name | Specifications | Model | Standards |
---|---|---|---|
Controller Link
Repeater Unit ![]() |
Wire-to-Wire Model | CS1W-RPT01 | UC1, CE |
Wire-to-Optical (H-PCF) Model *1 | CS1W-RPT02 | ||
Wire-to-Optical (GI) Model *2 | CS1W-RPT03 |
Name | Specifications | Model | Standards |
---|---|---|---|
Relay Terminal Blocks for
Wired Controller Link Units ![]() |
Used for Wired Controller Link Units (set of 5) | CJ1W-TB101 | - |
Controller Link Units can be replaced without stopping the communications of the entire network if a Relay Terminal Block is installed in advance on the Unit in a Wired Controller Link network. Relay Terminal Blocks cannot be used on Controller Link Support Boards.
Name | Application | Specifications | Model | Standards |
---|---|---|---|---|
Duplex Optical Fiber Cable |
CS1W-CLK13 or CS1W-CLK12-V1 * in a CS1D system |
H-PCF cable for connecting Duplex Controller Link Units Cable length: 50 cm |
CS1D-CN051 | - |
This cable is used to connect Units in active mode (ACT) and standby mode (STB) in a CS1D Duplex System.
* Discontinuation models in July 2012.
Name | Application/construction | Specifications | Model | Standards | |||
---|---|---|---|---|---|---|---|
Optical Fiber Cables | Controller
Link, SYSMAC LINK, SYSBUS |
![]() 1. Optical fiber single-core cord 2. Tension member (plastic-sheathed wire) 3. Filler (plastic) 4. Filler surrounding signal wires (plastic, yarn, or fiber) 5. Holding tape (plastic) 6. Heat-resistant PV sheath |
Two-
core optical cable with tension member |
Black 10 m | S3200-HCCB101 | - | |
Black 50 m | S3200-HCCB501 | ||||||
Black 100 m | S3200-HCCB102 | ||||||
Black 500 m | S3200-HCCB502 | ||||||
Black 1000 m | S3200-HCCB103 | ||||||
Orange 10 m | S3200-HCCO101 *1 | ||||||
Orange 50 m | S3200-HCCO501 *1 | ||||||
Orange 100 m | S3200-HCCO102 *1 | ||||||
Orange 500 m | S3200-HCCO502 *1 | ||||||
Orange 1000 m | S3200-HCCO103 *1 | ||||||
Optical
Connectors (Crimp-cut) |
![]() |
Controller Link:
CS1W-CLK13 CS1W-CLK12-V1 *1 3G8F7-CLK13-E *1 3G8F7-CLK12-EV1 *1 CS1W-RPT02 SYSMAC LINK: CS1W-SLK11 3G8F7-SLK11-E *1 C200HW-SLK13/14 *1 |
Half lock | S3200-COCF2571 | |||
![]() |
Controller Link:
CS1W-CLK13 CS1W-CLK12-V1 *1 3G8F7-CLK13-E *1 3G8F7-CLK12-EV1 *1 CS1W-RPT02 SYSMAC LINK: 3G8F7-SLK11-E *1 |
Full lock | S3200-COCF2071
*2 |
Application | Appearance | Model | Standards |
---|---|---|---|
Controller Link,
SYSMAC LINK |
![]() |
S3200-CN[][][]-20-20 | - |
![]() |
S3200-CN[][][]-20-25 | ||
![]() |
S3200-CN[][][]-25-25 |
Optical connectors for H-PCF Optical Cables with Connectors are adhesive polished.
The following cable lengths are available: 2 m, 5 m, 15 m, and 20 m. For lengths of 21 m or more, contact your OMRON sales representative.
Name | Applicable Unit | Model | Manufacturer | Standards |
---|---|---|---|---|
Optical Fiber Assembly Tool * |
This tool is used on site for mounting crimp-cut connectors and hard plastic-clad silica optical fiber for optical transmission systems of SYSMAC C-series SYSBUS, SYSMAC LINK, and Controller Link. |
CAK-0057 | Sumitomo Electric Industries, Ltd. |
- |
last update: July 8, 2024