Item ZN-J25A ZN-J41A
Applicable Air Clean Unit ZN-A2502D ZN-A4105D
Power supply voltage 24V DC ±10%, Ripple (p-p):10% max.
Current consumption 300 mA max.
Discharge voltage ±7 kV max.
Discharge method Variable DC discharge
Static electricity
removal time (Typical) *1
5 s max.
Ion balance (Typical) *2 ±30 V max.
Indicator lamps Power (green), Cleaning notice (orange flashing),
Cleaning alarm (orange), High voltage error (red)
External output High voltage error, cleaning outputs:
Output from photo MOS relay (30V DC, 300 mA max.)
Functions Manual adjustment of ion balance, cleaning required detection,
high voltage detection
Ambient temperature range Operating and storage: 0 to 40°C (with no icing or condensation)
Ambient humidity range Operating and storage: 35% to 65% (with no condensation)
Materials Body: ABS, Needles: Tungsten
Outer dimensions (mm) 248 (W) × 310 (D) × 45 (H) 408 (W) × 470 (D) × 45 (H)
Weight (Packaged) Approx. 0.6 kg (Approx. 1.4 kg) Approx. 1.5 kg (Approx. 2.7 kg)
Accessories Instruction Sheet, Sealing parts, Mounting screws,
Connector cable for Air Clean Unit, English warning label

*1 Measurement conditions:
  Distance: 300 mm
  Air Clean Unit: ZN-A Series with airflow level 5 at center of air outlet
  Discharging from ±1000 V to ±100 V with a charge plate monitor (150 × 150 mm, 20 pF)
  Temperature: 18 to 28°C, Humidity: 35 to 55%
  Performance may not be satisfied if gases such as from solvents are in the measurement area.
*2 Measurement conditions:
  Distance: 300 mm
  Air Clean Unit: ZN-A Series with airflow level 5 at center of air outlet
  Measured for 10 sec by a charge plate monitor (150 × 150 mm, 20 pF)
  Temperature: 18 to 28°C, Humidity: 35 to 55%