CJ-series Output Units
last update: April 1, 2025
Unit
type |
Product
name |
Specifications | No.
of words allo- cated |
Current
consump- tion (A) |
Model | Stand-
ards |
|||||
---|---|---|---|---|---|---|---|---|---|---|---|
Output
type |
I/O
points |
Maximum
switching capacity |
Commons | External
con- nection |
5 V | 24 V | |||||
CJ1
Basic I/O Units |
Relay
Contact Output Units ![]() |
--- | 8
outputs |
250 VAC/
24 VDC, 2 A |
Inde-
pendent contacts |
Removable
terminal block |
1
words |
0.09 | 0.048
max. |
CJ1W-OC201 | UC1, N,
L, CE |
--- | 16
outputs |
250 VAC/
24 VDC, 2 A |
16 points,
1 common |
Removable
terminal block |
1
words |
0.11 | 0.096
max. |
CJ1W-OC211 | |||
Triac
Output Unit ![]() |
--- | 8
outputs |
250 VAC,
0.6 A |
8 points,
1 common |
Removable
terminal block |
1
words |
0.22 | --- | CJ1W-OA201 *
CJ1W-OA201-1 |
||
Tran-
sistor Output Units ![]() |
Sinking | 8
outputs |
12 to 24
VDC, 2 A |
4 points,
1 common |
Removable
terminal block |
1
words |
0.09 | --- | CJ1W-OD201 | ||
Sinking | 8
outputs |
12 to 24
VDC, 0.5 A |
8 points,
1 common |
Removable
terminal block |
1
words |
0.10 | --- | CJ1W-OD203 | |||
Sinking | 16
outputs |
12 to 24
VDC, 0.5 A |
16 points,
1 common |
Removable
terminal block |
1
words |
0.10 | --- | CJ1W-OD211 | |||
Sinking | 16
outputs (High speed) |
24 VDC,
0.5 A |
16 points,
1 common |
Removable
terminal block |
1
words |
0.15 | --- | CJ1W-OD213 | N, L,
CE |
||
Sinking | 32
outputs |
12 to 24
VDC, 0.5 A |
16 points,
1 common |
Fujitsu/
OTAX connector |
2
words |
0.14 | --- | CJ1W-OD231 | UC1, N,
L, CE |
||
Sinking | 32
outputs |
12 to 24
VDC, 0.5 A |
16 points,
1 common |
MIL
connector |
2
words |
0.14 | --- | CJ1W-OD233 | |||
Sinking | 32
outputs (High speed) |
24 VDC,
0.5 A |
16 points,
1 common |
MIL
connector |
2
words |
0.22 | --- | CJ1W-OD234 | N, L,
CE |
||
Sinking | 64
outputs |
12 to 24
VDC, 0.3 A |
16 points,
1 common |
Fujitsu/
OTAX connector |
4
words |
0.17 | --- | CJ1W-OD261 | UC1, N,
L, CE |
||
Sinking | 64
outputs |
12 to 24
VDC, 0.3 A |
16 points,
1 common |
MIL
connector |
4
words |
0.17 | --- | CJ1W-OD263 | |||
Sourcing | 8
outputs |
24 VDC,
2 A Short- circuit protection |
4 points,
1 common |
Removable
terminal block |
1
words |
0.11 | --- | CJ1W-OD202 | |||
Sourcing | 8
outputs |
24 VDC,
0.5 A Short- circuit protection |
8 points,
1 common |
Removable
terminal block |
1
words |
0.10 | --- | CJ1W-OD204 | |||
Sourcing | 16
outputs |
24 VDC,
0.5 A Short- circuit protection |
16 points,
1 common |
Removable
terminal block |
1
words |
0.10 | --- | CJ1W-OD212 | |||
Sourcing | 32
outputs |
24 VDC,
0.5 A Short- circuit protection |
16 points,
1 common |
MIL
connector |
2
words |
0.15 | --- | CJ1W-OD232 | |||
Sourcing | 64
outputs |
12 to 24
VDC, 0.3 A |
16 points,
1 common |
MIL
connector |
4
words |
0.17 | --- | CJ1W-OD262 |
* CJ1W-OA201 is not UC1 cULus (Class I Division 2 hazardous location certification). If cULus (Class I Div 2 hazardous location certification) is required, use CJ1W-OA201-1.
Connectors are not included for models with connectors. Either use one of the applicable connector listed below or use an applicable Connector-Terminal Block Conversion Unit or I/O Relay Terminal. For details on wiring methods, refer to Data Sheet.
Name | Con-
nection |
Remarks | Applicable Units | Model | Stand-
ards |
|
---|---|---|---|---|---|---|
40-pin
Con- nectors |
Soldered | Connector | Fujitsu FCN-361J040-AU | Fujitsu / OTAX Connectors:
CJ1W-ID231(32 inputs): 1 per Unit CJ1W-ID261 (64 inputs): 2 per Unit CJ1W-OD231 (32 outputs): 1 per Unit CJ1W-OD261 (64 outputs): 2 per Unit CJ1W-MD261 (32 inputs, 32 outputs): 2 per Unit |
C500-CE404 | --- |
Connector
Cover |
Fujitsu FCN-360C040-J2
OTAX N360C040J2 |
|||||
Crimped | Housing | Fujitsu FCN-363J040
OTAX N363J040 |
C500-CE405 | |||
Contactor | Fujitsu FCN-363J-AU
OTAX N363JAU |
|||||
Connector
Cover |
Fujitsu FCN-360C040-J2
OTAX N360C040J2 |
|||||
Pressure
welded |
Fujitsu FCN-367J040-AU/F | C500-CE403 | ||||
24-pin
Con- nectors |
Soldered | Connector | Fujitsu FCN-361J024-AU | Fujitsu / OTAX Connectors:
CJ1W-MD231 (16 inputs, 16 outputs): 2 per Unit |
C500-CE241 | |
Connector
Cover |
Fujitsu FCN-360C024-J2
OTAX N360C024J2 |
|||||
Pressure
welded |
Fujitsu FCN-367J024-AU/F
OTAX N367J024AUF |
C500-CE243 |
Name | Con-
nection |
Remarks | Applicable Units | Model | Stand-
ards |
---|---|---|---|---|---|
40-pin
Con- nectors |
Pressure
welded |
FRC5-AO40-3TOS | MIL Connectors:
CJ1W-ID232/233 (32 inputs): 1 per Unit CJ1W-OD232/233/234 (32 outputs):1 per Unit CJ1W-ID262 (64 inputs): 2 per Unit CJ1W-OD262/263 (64 outputs): 2 per Unit CJ1W-MD263/563 (32 inputs, 32 outputs): 2 per Unit |
XG4M-4030-T | --- |
Crimped | - | XG5N-401 * | |||
20-pin
Con- nectors |
Pressure
welded |
FRC5-AO20-3TOS | MIL Connectors:
CJ1W-MD232/233 (16 inputs, 16 outputs): 2 per Unit |
XG4M-2030-T | --- |
Crimped | - | XG5N-201 * |
* Crimp Contacts are also required. Refer to Data Sheet for details.
Size and Mounting are Refer to Data Sheet.
Type | Series | Number
of con- nector poles |
Number
of terminal block poles |
Wiring
method |
Terminal
type |
Common
terminals |
I/O Units | Model * | Stan-
dards |
---|---|---|---|---|---|---|---|---|---|
PLCs | XW2K | 40 | 36 | Push-In
Plus ![]() |
Spring | No | CJ1W-ID231
CJ1W-ID261 |
XW2K-40G-O32B | --- |
CJ1W-OD232
CJ1W-OD233 CJ1W-OD234 CJ1W-OD262 CJ1W-OD263 |
XW2K-40G-O32C | ||||||||
40 | 68 | Push-In
Plus ![]() |
Spring | Yes | CJ1W-ID231
CJ1W-ID261 |
XW2K-40G-O32B-OUT | |||
CJ1W-OD232
CJ1W-OD233 CJ1W-OD234 CJ1W-OD262 CJ1W-OD263 |
XW2K-40G-O32C-OUT | ||||||||
XW2R | 40 | 34 | Phillips
screw ![]() |
M3 | No | CJ1W-ID231
CJ1W-ID261 |
XW2R-J34GD-C3 | ||
CJ1W-OD232
CJ1W-OD233 CJ1W-OD234 CJ1W-OD262 CJ1W-OD263 |
XW2R-J34GD-C4 | ||||||||
40 | 34 | Slotted
screw (rise up) ![]() |
M3
(Euro- pean type) |
No | CJ1W-ID231
CJ1W-ID261 |
XW2R-E34GD-C3 | |||
CJ1W-OD232
CJ1W-OD233 CJ1W-OD234 CJ1W-OD262 CJ1W-OD263 |
XW2R-E34GD-C4 |
Appearance | Connectors | Cable lenght [m] | Model |
---|---|---|---|
XW2Z-[][][]B
![]() |
One 40-pin FCN Connector to
One 40-pin MIL Connector |
0.5 | XW2Z-050B |
1 | XW2Z-100B | ||
1.5 | XW2Z-150B | ||
2 | XW2Z-200B | ||
3 | XW2Z-300B | ||
5 | XW2Z-500B | ||
XW2Z-[][][]K
![]() |
One 40-pin MIL Connector to
One 40-pin MIL Connector |
0.5 | XW2Z-C50K |
1 | XW2Z-100K | ||
1.5 | XW2Z-150K | ||
2 | XW2Z-200K | ||
3 | XW2Z-300K | ||
5 | XW2Z-500K |
Size (horizontal mounting) and Mounting are Refer to Data Sheet.
Type/
Series |
Specifications | Model | Stand-
ards |
|||||
---|---|---|---|---|---|---|---|---|
Classification | Po-
lar- ity |
Number
of points |
Rated
ON cur- rent at contacts |
Rated
voltage |
||||
Push-In
Plus terminal block/ G70V |
In-
puts |
DC
inputs |
NPN | 16
(SPST- NO × 16) |
50 mA | 24 VDC | G70V-SID16P *4 | UC,
CE (TÜV certi- fied) |
PNP | G70V-SID16P-1 *4 | |||||||
NPN | G70V-SID16P-C16 *5 | |||||||
PNP | G70V-SID16P-1-C16 *5 | |||||||
Out-
puts |
Relay
outputs |
NPN | 16
(SPDT × 16) |
6 A/
point, 10 A/ common |
G70V-SOC16P *4 | |||
PNP | G70V-SOC16P-1 *4 | |||||||
NPN | G70V-SOC16P-C4 *6 | |||||||
PNP | G70V-SOC16P-1-C4 *6 | |||||||
Standard/
G7TC |
In-
puts |
AC
inputs |
NPN | 16
(SPST- NO × 16) |
1A | 100/(110)
VAC |
G7TC-IA16 AC100/110 | U, C |
200/(220)
VAC |
G7TC-IA16 AC200/220 | |||||||
DC
inputs |
12 VDC | G7TC-ID16 DC12 | ||||||
24 VDC | G7TC-ID16 DC24 | |||||||
100/110
VDC |
G7TC-ID16 DC100/110 | |||||||
Out-
puts |
Relay
outputs |
NPN | 8
(SPST- NO × 8) |
5A | 12 VDC | G7TC-OC08 DC12 | ||
24 VDC | G7TC-OC08 DC24 | |||||||
16
(SPST- NO × 16) |
12 VDC | G7TC-OC16 DC12 | ||||||
24 VDC | G7TC-OC16 DC24 | |||||||
PNP | 16
(SPST- NO × 16) |
12 VDC | G7TC-OC16-1 DC12 | |||||
24 VDC | G7TC-OC16-1 DC24 | |||||||
High-
capacity socket/ G70A *1 (Socket only) |
In-
puts |
Relay
inputs |
NPN/
PNP |
16
(SPDT × 16 possible with G2R Relays) |
100 mA | 110 VDC
max., 240 VAC max. *2 |
G70A-ZOC16-5 | U, C,
CE (VDE certi- fied) |
Out-
puts |
Relay
outputs |
NPN | 10 A
(Terminal block allowable |
24 VDC | G70A-ZOC16-3 | |||
PNP | G70A-ZOC16-4 | |||||||
Space-
saving/ Vertical type G70D-V |
Out-
puts |
Relay
outputs |
NPN | 16
(SPST- NO × 16) |
5 A or
3 A *3 |
24 VDC | G70D-VSOC16 | U, C,
CE (VDE certi- fied) |
MOSFET
relay outputs |
0.3 A | G70D-VFOM16 | ||||||
Space-
saving/ Flat type G70D |
Relay
outputs |
NPN | 8
(SPST- NO × 8) |
5 A | G70D-SOC08 | - | ||
16
(SPST- NO × 16) |
3 A | G70D-SOC16 | ||||||
PNP | 16
(SPST- NO × 16) |
3 A | G70D-SOC16-1 | |||||
MOSFET
relay outputs |
NPN | 16
(SPST- NO × 16) |
0.3 A | G70D-FOM16 | ||||
PNP | G70D-FOM16-1 *7 | |||||||
High-
capacity, space- saving/ G70R |
Out-
puts |
Relay
outputs |
NPN | 8
(SPST- NO × 8) |
10 A | 24 VDC | G70R-SOC08 *7 | - |
Type | Name | I/O
Classifi- cation |
Appearance | Cable length
L (mm) |
Models |
---|---|---|---|---|---|
Fujitsu/OTAX
connectors (24 pins) |
Cables with
Connectors (1:1) XW2Z-R[]C |
16 I/O
points |
![]() |
1,000 | XW2Z-R100C |
1,500 | XW2Z-R150C | ||||
2,000 | XW2Z-R200C | ||||
3,000 | XW2Z-R300C | ||||
5,000 | XW2Z-R500C | ||||
Fujitsu/OTAX
connectors (40 pins) |
Cables with
Connectors (1:2) XW2Z-RI[]C-[] XW2Z-RO[]C-[] |
32 input
points |
![]() |
(A) 1,000
(B) 750 |
XW2Z-RI100C-75 |
(A) 1,500
(B) 1,250 |
XW2Z-RI150C-125 | ||||
(A) 2,000
(B) 1,750 |
XW2Z-RI200C-175 | ||||
(A) 3,000
(B) 2,750 |
XW2Z-RI300C-275 | ||||
(A) 5,000
(B) 4,750 |
XW2Z-RI500C-475 | ||||
32 output
points |
(A) 1,000
(B) 750 |
XW2Z-RO100C-75 | |||
(A) 1,500
(B) 1,250 |
XW2Z-RO150C-125 | ||||
(A) 2,000
(B) 1,750 |
XW2Z-RO200C-175 | ||||
(A) 3,000
(B) 2,750 |
XW2Z-RO300C-275 | ||||
(A) 5,000
(B) 4,750 |
XW2Z-RO500C-475 | ||||
MIL
connectors (20 pins) |
Cables with
Connectors (1:1) XW2Z-RI[]C XW2Z-RO[]C |
16 I/O
points |
![]() |
250 | XW2Z-RI25C |
500 | XW2Z-RI50C | ||||
250 | XW2Z-RO25C | ||||
500 | XW2Z-RO50C | ||||
MIL
connectors (40 pins) |
Cables with
Connectors (1:2) XW2Z-RO[]-[]-D1, XW2Z-RI[]-[]-D1 |
32 I/O
points |
![]() |
(A) 500
(B) 250 |
XW2Z-RO50-25-D1 |
(A) 750
(B) 500 |
XW2Z-RO75-50-D1 | ||||
(A) 1,000
(B) 750 |
XW2Z-RO100-75-D1 | ||||
(A) 1,500
(B) 1,250 |
XW2Z-RO150-125-D1 | ||||
(A) 2,000
(B) 1,750 |
XW2Z-RO200-175-D1 | ||||
(A) 3,000
(B) 2,750 |
XW2Z-RO300-275-D1 | ||||
(A) 5,000
(B) 4,750 |
XW2Z-RO500-475-D1 | ||||
(A) 500
(B) 250 |
XW2Z-RI50-25-D1 | ||||
(A) 750
(B) 500 |
XW2Z-RI75-50-D1 | ||||
(A) 1,000
(B) 750 |
XW2Z-RI100-75-D1 | ||||
(A) 1,500
(B) 1,250 |
XW2Z-RI150-125-D1 | ||||
(A) 2,000
(B) 1,750 |
XW2Z-RI200-175-D1 | ||||
(A) 3,000
(B) 2,750 |
XW2Z-RI300-275-D1 | ||||
(A) 5,000
(B) 4,750 |
XW2Z-RI500-475-D1 |
Note: Refer to the Datasheet for the XW2Z-R Cables for I/O Relay Terminals (Cat. No. G126).
last update: April 1, 2025