Page top

Industrial Automation

Industrial Automation

F03-05, PH-1 / -2

Electrode Bands / Underwater Electrode

F03-05, PH-1 / -2

Easy Mounting and Removal. Ideal for Applications in Deep Wells.

Electrode Bands

Model F03-05 3P F03-05 4P F03-05 5P
Outer sheath PVC
Core SUS304, 0.3 dia. x 21 twisted wires
Weight Approx. 110 g (1 m) Approx. 140 g (1 m) Approx. 180 g (1 m)
Operating temperature -10 to +60°C (with no icing) *
Applicable Electrode Holders PS-3S, -4S, -5S BF-3, -5

*The Electrode Band cannot be used in flowing water, liquids over 60°C, or liquids which corrode PVC or stainless steel.

Underwater Electrodes

Model PH-1 PH-2
Vinyl cable Hypalon cable Vinyl cable Hypalon cable
Cable length 100 m max.
Operating temperature -10 to +60°C -30 to +70°C -10 to +60°C -30 to +70°C
Weight Electrode + 1 m cable Approx. 140 g Approx. 140 g Approx. 230 g Approx. 230 g
Cable (per meter) Approx. 40 g Approx. 40 g Approx. 60 g Approx. 60 g

Note: 1. The PH-1 and PH-2 are vinyl cables unless specified otherwise.
         2. "ビニソフト" is printed in Japanese on the actual vinyl cable.
         3. Hypalon is a registered trademark of Mitsui Chemicals, Inc.

Required No. of Electrode Band Accessories (Order Separately)

Product Model Weight per unit (g) F03-05 3P F03-05 4P F03-05 5P
Electrode Band
Connecting Nut
F03-06 Approx. 20 3 4 5
Electrode Band
Weight
F03-07 Approx. 50 3 to 4 4 to 6 5 to 8
Electrode Band
End Cap
F03-08 Approx. 1 2 3 4
Electrode Band
Insulation Cap
F03-09 Approx. 10 2 3 4
Electrode Band
Adhesive
F03-10 Approx. 5 1 1 1

Note: One tube of F03-10 (adhesive) can be used for approximately 5 times of end cap fixation.