Smart Laser Sensors
last update: August 2, 2017
Sensing method | Coaxial Retro-reflective with MSR function | |||
---|---|---|---|---|
Model | E3NC-LH03 | E3NC-LH03+
E39-P51 |
||
Light source (wavelength) *1 | Visible semiconductor laser diode (660 nm), 1.35 mW (average output:
315 μW) (JIS Class 1, IEC/EN Class 1, and FDA Class 1) |
|||
Sensing
distance *2 |
Giga-power mode (GIGA) | 8 m | 0.5 m | |
Standard mode (Stnd) | 6 m | |||
High-speed mode (HS) | 3.5 m | |||
Super-high-speed mode
(SHS) |
2 m | |||
Beam shape | Spot | Line | ||
Beam size *3 | Approx. 2 mm dia. at 1 m | Line length: Approx. 25 mm at
250 mm Line length: Approx. 50 mm at 500 mm |
||
Differential distance *4 | --- | |||
Indicators | OUT indicator (orange) and STABILITY indicator (green) | |||
Ambient illumination (Receiver side) | Incandescent lamp: 10,000 lx max.,
Sunlight: 20,000 lx max. |
|||
Ambient temperature range | Operating: -10 to 55°C; Storage: -25 to 70°C (with no icing or
condensation) |
|||
Ambient humidity range | Operating and storage: 35% to 85% (with no condensation) | |||
Altitude | 2,000 m max. | |||
Installation environment | Pollution degree 3 (as per IEC 60947-1) | |||
Insulation resistance | 20 MΩ min. (at 500 VDC) | |||
Dielectric strength | 1,000 VAC at 50/60 Hz for 1 min | |||
Vibration resistance (destruction) | 10 to 55 Hz with a 1.5-mm double amplitude or 100 m/s2 for 2 hours each
in X, Y, and Z directions |
|||
Shock resistance (destruction) | 500 m/s2 for 3 times each in X, Y, and Z directions | |||
Degree of protection | IEC IP67 *5 | |||
Connecting method | Pre-wired connector (standard length: 2 m) | |||
Materials | Sensor Head | Case | Polybutylene terephthalate (PBT) | |
Lens | Methacrylic resin (PMMA) | |||
Cable | Vinyl chloride (PVC) | |||
Lens
Attachment |
Case | --- | ABS | |
Lens | --- | Methacrylic resin (PMMA) | ||
Weight (packed
state/Sensor Head only) |
Models with 2-m cable | Approx. 120 g/approx. 70 g | ||
Models with 5-m cable | Approx. 180 g/approx. 130 g | |||
Lens Attachment | --- | Approx. 25 g/approx. 2 g | ||
Accessories | Instruction Manual |
Sensing method | Diffuse-reflective | Limited reflective | |||
---|---|---|---|---|---|
Model | E3NC-LH02 | E3NC-LH02+
E39-P52 |
E3NC-LH01 | ||
Light source (wavelength) *1 | Visible semiconductor laser diode (660 nm), 1.35 mW (average output:
315 μW) (JIS Class 1, IEC/EN Class 1, and FDA Class 1) |
||||
Sensing
distance *2 |
Giga-power mode (GIGA) | 1,200 mm | 1,000 mm | 70±15 mm | |
Standard mode (Stnd) | 750 mm | 600 mm | |||
High-speed mode (HS) | 250 mm | 200 mm | |||
Super-high-speed mode
(SHS) |
200 mm | 150 mm | |||
Beam shape | Spot | Line | Spot | ||
Beam size *3 | Approx. 0.8 mm dia. at
300 mm |
Line length: Approx. 45
mm at 500 mm Line length: Approx. 100 mm at 1,000 mm |
Approx. 0.1 mm dia. at
70 mm |
||
Differential distance *4 | 10% of sensing distance max. | ||||
Indicators | OUT indicator (orange) and STABILITY indicator (green) | ||||
Ambient illumination (Receiver side) | Incandescent lamp: 10,000 lx max.,
Sunlight: 20,000 lx max. |
||||
Ambient temperature range | Operating: -10 to 55°C; Storage: -25 to 70°C (with no icing or
condensation) |
||||
Ambient humidity range | Operating and storage: 35% to 85% (with no condensation) | ||||
Altitude | 2,000 m max. | ||||
Installation environment | Pollution degree 3 (as per IEC 60947-1) | ||||
Insulation resistance | 20 MΩ min. (at 500 VDC) | ||||
Dielectric strength | 1,000 VAC at 50/60 Hz for 1 min | ||||
Vibration resistance (destruction) | 10 to 55 Hz with a 1.5-mm double amplitude or 100 m/s2 for 2 hours
each in X, Y, and Z directions |
||||
Shock resistance (destruction) | 500 m/s2 for 3 times each in X, Y, and Z directions | ||||
Degree of protection | IEC IP65 (E3NC-LH02: Applies only when adjuster is locked.) *5 | ||||
Connecting method | Pre-wired connector (standard length: 2 m) | ||||
Materials | Sensor
Head |
Case | Polybutylene terephthalate (PBT) | ||
Lens | Methacrylic resin (PMMA) | ||||
Cable | Vinyl chloride (PVC) | ||||
Lens
Attachment |
Case | --- | ABS | --- | |
Lens | --- | Methacrylic resin
(PMMA) |
--- | ||
Weight (packed
state/Sensor Head only) |
Models with 2-m cable | Approx. 115 g/approx. 65 g | |||
Models with 5-m cable | Approx. 175 g/approx. 125 g | ||||
Lens Attachment | --- | Approx. 25 g/approx. 2 g | --- | ||
Accessories | Instruction Manual |
Type | Standard models | Model for Sensor
Communications Unit |
|||
---|---|---|---|---|---|
NPN output | E3NC-LA21 | E3NC-LA7 | E3NC-LA24 | E3NC-LA0 | |
PNP output | E3NC-LA51 | E3NC-LA9 | E3NC-LA54 | ||
Connecting method | Pre-wired | Wire-saving
Connector |
M8
Connector |
Connector for Sensor
Communications Unit |
|
Inputs/
outputs |
Outputs | 2 outputs | 1 output | --- *1 | |
External inputs | 1 input | ||||
Power supply voltage *2 | 10 to 30 VDC, including 10% ripple (p-p) | Supplied from the
connector through the Sensor Communications Unit |
|||
Power consumption *3 | At Power Supply Voltage of 24 VDC
Normal mode: 1,560mW max. (Current consumption: 65mA max.) Eco ON: 1,320 mW max. (Current consumption: 55 mA max.) Eco LO: 1,440 mW max. (Current consumption: 60 mA max.) |
||||
Control outputs *4 | Load power supply voltage: 30 VDC max.,
open-collector output Load current: Groups of 1 to 3 Amplifier Units: 100 mA max., Groups of 4 to 30 Amplifier Units: 20 mA max. (Residual voltage: At load current of less than 10 mA: 1 V max. At load current of 10 to 100 mA: 2 V max.) OFF current: 0.1 mA max. |
--- | |||
External inputs | Refer to *5. | --- | |||
Indicators | 7-segment displays (Sub digital display: green, Main digital display: white)
Display direction: Switchable between normal and reversed. OUT indicator (orange), L/D indicator (orange), ST indicator (blue), DPC indicator (green), and OUT selection indicator (orange, only on models with 2 outputs) |
||||
Protection circuits | Power supply reverse polarity protection,
output short-circuit protection, and output reverse polarity protection |
Power supply reverse
polarity protection and output short-circuit protection |
|||
Response
time |
Super-high-speed mode (SHS) *6 | Operate or reset: 80 μs | |||
High-speed mode (HS) | Operate or reset: 250 μs | ||||
Standard mode (Stnd) | Operate or reset: 1 ms | ||||
Giga-power mode (GIGA) | Operate or reset: 16 ms | ||||
Sensitivity adjustment | Smart Tuning (2-point tuning, full auto tuning, position tuning, maximum sensitivity tuning, power tuning,
or percentage tuning (-99% to +99%)), or manual adjustment. |
||||
Maximum connectable Units | 30 | With E3NW-ECT: 30 units *7
With E3NW-CRT: 16 units With E3NW-CCL: 16 units |
|||
No. of Units
for mutual interference prevention |
Super-high-speed mode (SHS) *6 | 0 | |||
High-speed mode (HS) | 2 | ||||
Standard mode (Stnd) | 2 | ||||
Giga-power mode (GIGA) | 4 | ||||
Functions | Dynamic power control (DPC) | Provided | |||
Timer | Select from timer disabled, OFF-delay, ON-delay, one-shot, or ON-delay
+ OFF-delay timer: 1 to 9,999 ms |
||||
Zero reset | Negative values can be displayed. (Threshold value is shifted.) | ||||
Resetting settings *8 | Select from initial reset (factory defaults) or user reset (saved settings). | ||||
Eco mode *9 | Select from OFF (digital display lit), ECO ON (digital display not lit), and ECO LO (digital display dimmed). | ||||
Bank switching | Select from banks 1 to 4. | ||||
Power tuning | Select from ON or OFF. | ||||
Output 1 | Select from Normal Detection Mode or Area Detection Mode. | ||||
Output 2 | Select from
normal detection mode, alarm output mode, or error output mode. |
--- | Select from normal
detection mode, alarm output mode, or error output mode. |
||
External input | Select from input OFF, tuning, power tuning,
laser OFF, zero reset, or bank switching. |
--- | |||
Hysteresis width | Select from standard setting or user setting. | ||||
Ambient temperature range* | Operating:
Groups of 1 or 2 Amplifier Units: -25 to 55°C, Groups of 3 to 10 Amplifier Units: -25 to 50°C, Groups of 11 to 16 Amplifier Units: -25 to 45°C, Groups of 17 to 30 Amplifier Units: -25 to 40°C Storage: -30 to 70°C (with no icing or condensation) |
Operating:
Groups of 1 or 2 Amplifier Units: 0 to 55°C, Groups of 3 to 10 Amplifier Units: 0 to 50°C, Groups of 11 to 16 Amplifier Units: 0 to 45°C, Groups of 17 to 30 Amplifier Units: 0 to 40°C, Storage: -30 to 70°C (with no icing or condensation) |
|||
Ambient humidity range | Operating and storage: 35% to 85% (with no condensation) | ||||
Altitude | 2,000 m max. | ||||
Installation environment | Pollution degree 3 (as per IEC 60947-1) | ||||
Insulation resistance | 20 MΩ (at 500 VDC) | ||||
Dielectric strength | 1,000 VAC at 50/60 Hz for 1 min | ||||
Vibration resistance (destruction) | 10 to 55 Hz with a 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions | ||||
Shock resistance (destruction) | 500 m/s2 for 3 times each in X, Y, and Z directions | 150m/s2 for 3 times each in
X, Y, and Z directions |
|||
Weight (packed state/Amplifier Unit only) | Approx. 115 g/
approx. 75 g |
Approx. 60 g/
approx. 20 g |
Approx. 65 g/approx. 25 g | ||
Materials | Case | Polycarbonate (PC) | |||
Cover | Polycarbonate (PC) | ||||
Cable | Vinyl chloride (PVC) | ||||
Accessories | Instruction Manual |
*1. Two sensor outputs are allocated in the programmable logic controller PLC I/O table.
PLC operation via Communications Unit enables reading detected values and changing settings.
*2. Applicable Sensor Head is the series of E3NC-LH[][] (Input/Output 10-30V DC Class 2)
*3. At Power Supply Voltage of 10 to 30 VDC.
Normal mode: 1,650 mW max. (Current consumption: 55 mA max. at 30 VDC, 115 mA max. at 10 VDC)
Eco ON: 1,410 mW max. (Current consumption: 47 mA max. at 30 VDC, 95 mA max. at 10 VDC)
Eco LO: 1,530 mW max. (Current consumption: 51 mA max. at 30 VDC, 105 mA max. at 10 VDC)
*4. The total for both outputs of a model with 2 outputs is 100 mA max.
(Residual voltage: Load current of less than 10 mA: 1 V max., Load current of 10 to 100 mA:2 V max.).
*5. The following details apply to the input.
Contact input (relay or switch) | Non-contact input (transistor) | Input time*5-1 | |
---|---|---|---|
NPN | ON: Shorted to 0 V
(Sourcing current: 1 mA max.). OFF: Open or shorted to Vcc. |
ON: 1.5 V max. (Sourcing current: 1 mA max.)
OFF: Vcc - 1.5 V to Vcc (Leakage current: 0.1 mA max.) |
ON: 9 ms min.
OFF: 20 ms min. |
PNP | ON: Shorted to Vcc
(Sinking current: 3 mA max.). OFF: Open or shorted to 0 V. |
ON: Vcc - 1.5 V to Vcc (Sinking current: 3 mA max.)
OFF: 1.5 V max. (Leakage current: 0.1 mA max.) |
*5-1.Input time is 25 ms (ON)/(OFF) only when (in tUnE) or (in PtUn) input is selected.
*6. The mutual interference prevention function is disabled if the detection mode is set to super-high-speed mode.
*7. When connected to an OMRON NJ-series Controller.
*8. The bank is not reset by the user reset function or saved by the user save function.
*9. Eco LO is supported for Amplifier Units manufactured in July 2014 or later.
* When the number of connected units is 11 or more, the ambient temperature is less than 50°C.
Model | E39-R21 | E39-R22 | E39-RS10 | E39-RS11 |
---|---|---|---|---|
Ambient temperature | Operating: -10 to 55°C; Storage: -25 to 70°C (with no icing or condensation) | |||
Ambient humidity | Operating/storage: 35% to 85% (with no condensation) | |||
Vibration resistance
(destruction) |
10 to 55 Hz with a 1.5-mm double amplitude or 100 m/s2 for 2 hours each in X, Y, and Z directions | |||
Shock resistance
(destruction) |
500 m/s2 3 times each in X, Y, and Z directions | |||
Degree of protection | IEC IP67 (E39-R21 and E39-R22 only) | |||
Materials | Reflective surface: Methacrylic resin (PMMA)
Back surface: Polybutylene terephthalate (PBT) |
Methacrylic resin (PMMA) | ||
Weight
(packed state/ Reflector only) |
Approx. 30 g/
approx. 5 g |
Approx. 35 g/
approx. 10 g |
Approx. 35 g/
approx. 10 g |
Approx. 30 g/
approx. 5 g |
Accessories | Instruction manual |
Sensing method | Distance-settable | |||
---|---|---|---|---|
Model | E3NC-SH250H | E3NC-SH250 | E3NC-SH100 | |
Light source (wavelength)*1 | Visible semiconductor
laser diode (660 nm), 1 mW (average output: 220 μW) (JIS Class 2, IEC/EN Class 2, and FDA Class 2) |
Visible semiconductor laser diode (660 nm), 0.5 mW
(average output: 100 μW) (JIS Class 1, IEC/EN Class 1, and FDA Class 1) |
||
Measurement range | 35 to 250 mm (display value: 350 to 2,500) | 35 to 100 mm (display
value: 350 to 1,000) |
||
Standard detected level
difference *2 |
35 to 180mm: 9 mm
180 to 250 mm: 25 mm |
35 to 50 mm: 1.5 mm
50 to 100 mm: 3 mm |
||
Beam size*3 | Approx. 1 mm dia. at 250 mm | Approx. 0.5 mm dia. at 100 mm | ||
Indicators | OUT indicator (orange), STABILITY indicator (green), and ST indicator (blue) | |||
Ambient illumination
(Receiver side) |
Incandescent lamp:
4,000 lx max., Sunlight: 8,000 lx max. |
Incandescent lamp:
2,000 lx max., Sunlight: 4,000 lx max. |
Incandescent lamp:
4,000 lx max., Sunlight: 8,000 lx max. |
|
Ambient temperature range | Operating: -10 to 50°C; Storage: -25 to 70°C (with no icing or condensation) | |||
Ambient humidity range | Operating and storage: 35% to 85% (with no condensation) | |||
Altitude | 2,000 m max. | |||
Installation environment | Pollution degree 3 (as per IEC 60947-1) | |||
Insulation resistance | 20 MΩ min. (at 500 VDC) | |||
Dielectric strength | 1,000 VAC at 50/60 Hz for 1 min | |||
Vibration resistance
(destruction) |
10 to 55 Hz with a 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions | |||
Shock resistance
(destruction) |
500 m/s2 3 times each in X, Y, and Z directions | |||
Degree of protection | IEC IP67 | |||
Connecting method | Pre-wired connector (Standard cable length: 2 m) | |||
Materials | Case | Polybutylene terephthalate (PBT) | ||
Lens | Methacrylic resin (PMMA) | |||
Cable | Vinyl chloride (PVC) | |||
Weight (packed state/
Sensor Head only) |
Approx. 125 g/approx. 75 g | |||
Accessories | Instruction Manual, laser warning label (E3NC-SH250H only) |
Note: Incorrect detection may occur outside the measurement range if the object has a high reflection factor.
*1. These Sensors are classified as Class 1 laser devices under IEC 60825-1 and the regulations of Laser Notice No. 50
for FDA certification.
CDRH (Center for Devices and Radiological Health) registration has been completed. (Accession Number: 1220691)
*2. The values were measured at the center of the sensing distance using OMRON’s standard sensing object
(white ceramic).
*3. Beam size: Defined at the 1/e2 (13.5 %) of the central intensity at the measurement center distance.
Measurement may be influenced if there is light leakage outside the defined region and the surroundings of the target
object have a high reflectance in comparison to the target object.
Also, when detecting a workpiece that is smaller than the beam size, a correct value may not be obtained.
Type | Standard models | Model for Sensor
Communications Unit |
|||
---|---|---|---|---|---|
NPN output | E3NC-SA21 | E3NC-SA7 | E3NC-SA24 | E3NC-SA0 | |
PNP output | E3NC-SA51 | E3NC-SA9 | E3NC-SA54 | ||
Connecting method | Pre-wired | Wire-saving
Connector |
M8
Connector |
Connector for Sensor
Communications Unit |
|
Inputs/
outputs |
Outputs | 2 outputs | 1 output | --- *1 | |
External inputs | 1 input | ||||
Power supply voltage *2 | 10 to 30 VDC, including 10% ripple (p-p) | Supplied from the
connector through the Sensor Communications Unit |
|||
Power consumption *3 | At Power Supply Voltage of 24 VDC
Normal mode: 1,920 mW max. (Current consumption: 80 mA max.) Eco ON: 1,680 mW max. (Current consumption: 70 mA max.) Eco LO: 1,800 mW max. (Current consumption: 75 mA max.) |
||||
Control outputs *4 | Load power supply voltage: 30 VDC max.,
open-collector output Load current: Groups of 1 to 3 Amplifier Units: 100 mA max., Groups of 4 to 30 Amplifier Units: 20 mA max. (Residual voltage: At load current of less than 10 mA: 1 V max. At load current of 10 to 100 mA: 2 V max.) OFF current: 0.1 mA max. |
―― | |||
External inputs | Refer to *5. | ||||
Indicators | 7-segment displays (Sub digital display: green, Main digital display: white)
Display direction: Switchable between normal and reversed. OUT indicator (orange), L/D indicator (orange), ST indicator (blue), ZERO indicator (green), and OUT selection indicator (orange, only on models with 2 outputs) |
||||
Protection circuits | Power supply reverse polarity protection,
output short-circuit protection, and output reverse polarity protection |
Power supply reverse
polarity protection and output short-circuit protection |
|||
Response
time |
Super-high-speed mode (SHS) *6 | Operate or reset: 1.5 ms | |||
High-speed mode (HS) | Operate or reset: 5 ms | ||||
Standard mode (Stnd) | Operate or reset: 10 ms | ||||
Giga-power mode (GIGA) | Operate or reset: 50 ms | ||||
Sensitivity adjustment | Smart Tuning (2-point tuning, full auto tuning, 1-point tuning, tuning without workpiece,
2-point area tuning, 1-point area tuning, or area tuning without workpiece), or manual adjustment |
||||
Maximum connectable Units | 30 | With E3NW-ECT: 30 units *7
With E3NW-CRT: 16 units With E3NW-CCL: 16 units |
|||
No. of Units
for mutual interference prevention |
Super-high-speed mode (SHS) *6 | 0 | |||
High-speed mode (HS) | 2 | ||||
Standard mode (Stnd) | 2 | ||||
Giga-power mode (GIGA) | 2 | ||||
Functions | Timer | Select from timer disabled, OFF-delay, ON-delay, one-shot, or ON-delay
+ OFF-delay timer: 1 to 9,999 ms |
|||
Zero reset | Negative values can be displayed. (Threshold value is shifted.) | ||||
Resetting settings *8 | Select from initial reset (factory defaults) or user reset (saved settings). | ||||
Eco mode *9 | Select from OFF (digital display lit), ECO ON (digital display not lit), and ECO LO (digital display dimmed). | ||||
Bank switching | Select from banks 1 to 4. | ||||
Output 1 | Select from Normal detection mode, Area detection mode, or hold mode. | ||||
Output 2 | Select from
Normal detection mode or Error output mode. |
--- | Select from Normal
detection mode or Error output mode. |
||
External input | Select from input OFF, tuning, laser OFF,
zero reset, or bank switching. |
―― | |||
Keep function *10 | Select from ON or OFF. | ||||
Background suppression *11 | Select from ON or OFF. | ||||
Hysteresis width | Select from standard setting or user setting. | ||||
Ambient temperature range* | Operating:
Groups of 1 or 2 Amplifier Units: -25 to 55°C, Groups of 3 to 10 Amplifier Units: -25 to 50°C, Groups of 11 to 16 Amplifier Units: -25 to 45°C, Groups of 17 to 30 Amplifier Units: -25 to 40°C Storage: -30 to 70°C (with no icing or condensation) |
Operating:
Groups of 1 or 2 Amplifier Units: 0 to 55°C, Groups of 3 to 10 Amplifier Units: 0 to 50°C, Groups of 11 to 16 Amplifier Units: 0 to 45°C, Groups of 17 to 30 Amplifier Units: 0 to 40°C Storage: -30 to 70°C (with no icing or condensation) |
|||
Ambient humidity range | Operating and storage: 35% to 85% (with no condensation) | ||||
Insulation resistance | 20 MΩ (at 500 VDC) | ||||
Altitude | 2,000 m max. | ||||
Installation environment | Pollution degree 3 (as per IEC 60947-1) | ||||
Dielectric strength | 1,000 VAC at 50/60 Hz for 1 min | ||||
Vibration resistance (destruction) | 10 to 55 Hz with a 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions | ||||
Shock resistance (destruction) | 500 m/s2 for 3 times each in X, Y, and Z directions | 150 m/s2 for 3 times each
in X, Y, and Z directions |
|||
Weight (packed state/Amplifier Unit only) | Approx. 115 g/
approx. 75 g |
Approx. 60 g/
approx. 20 g |
Approx. 65 g/approx. 25 g | ||
Materials | Case | Polycarbonate (PC) | |||
Cover | Polycarbonate (PC) | ||||
Cable | Vinyl chloride (PVC) | ||||
Accessories | Instruction Manual |
*1. Two sensor outputs are allocated in the programmable logic controller PLC I/O table.
PLC operation via Communications Unit enables reading detected values and changing settings.
*2. Applicable Sensor Head is the series of E3NC-SH[][] (Input/Output 10-30V DC Class 2).
*3. At Power Supply Voltage of 10 to 30 VDC.
Normal mode: 2,250 mW max. (Current consumption: 75 mA max. at 30 VDC, 145 mA max. at 10 VDC)
Eco ON: 2,010 mW max. (Current consumption: 67 mA max. at 30 VDC, 125 mA max. at 10 VDC)
Eco LO: 2,130 mW max. (Current consumption: 71 mA max. at 30 VDC, 135 mA max. at 10 VDC)
*4. The total for both outputs of a model with 2 outputs is 100 mA max.
(Residual voltage: Load current of less than 10 mA: 1 V max., Load current of 10 to 100 mA: 2 V max.).
*5. The following details apply to the input.
Contact input (relay or switch) | Non-contact input (transistor) | Input time*5-1 | |
---|---|---|---|
NPN | ON: Shorted to 0 V
(Sourcing current: 1 mA max.). OFF: Open or shorted to Vcc. |
ON: 1.5 V max. (Sourcing current: 1 mA max.)
OFF: Vcc - 1.5 V to Vcc (Leakage current: 0.1 mA max.) |
ON: 9 ms min.
OFF: 20 ms min. |
PNP | ON: Shorted to Vcc
(Sinking current: 3 mA max.). OFF: Open or shorted to 0 V. |
ON: Vcc - 1.5 V to Vcc (Sinking current: 3 mA max.)
OFF: 1.5 V max. (Leakage current: 0.1 mA max.) |
*5-1.Input time is 25 ms (ON)/(OFF) only when (in tUnE) input is selected.
*6. The mutual interference prevention function is disabled if the detection mode is set to super-high-speed mode.
*7. When connected to an OMRON NJ-series Controller.
*8. The bank is not reset by the user reset function or saved by the user save function.
*9. Eco LO is supported for Amplifier Units manufactured in August 2014 or later.
*10. The output for a measurement error is set.
ON: The value of the output from before the measurement error is retained.
OFF: The output is turned OFF when a measurement error occurs.
*11. Only the sensing object is detected when tuning.
* When the number of connected units is 11 or more, the ambient temperature is less than 50°C.
last update: August 2, 2017