Phase-sequence Phase-loss Relay
* Information in this page is a reference that you created on the basis of information in the product catalog before the end of production, may be different from the current situation, such as goods for / supported standards options / price / features of the product. Before using, please check the compatibility and safety system.
last update: February 3, 2014
| Rated input voltage | Three-phase, three-wire mode, 200 to 500 VAC |
|---|---|
| Input load | 15 VA max. |
| Reversed phase and phase loss
operating time |
0.1 s max. |
| Reset method | Automatic reset |
| Indicators | Power (PWR): Green, Relay output (RY): Yellow |
| Output relays | One SPDT relay (NC operation) |
| Output relay ratings | Rated load
Resistive load 6 A at 250 VAC (cosφ = 1) 6 A at 30 VDC (L/R = 0 ms) Inductive load 1 A at 250 VAC (cosφ = 0.4) 1 A at 30 VDC (L/R = 7 ms) Maximum contact voltage: 250 VAC Maximum contact current: 6 A AC Maximum switching capacity: 1,500 VA Minimum load: 10 mA at 5 VDC Mechanical life: 1,000,000 operations Electrical life: Make: 25,000 times, Break: 15,000 times |
| Ambient operating temperature | -20 to 60°C (with no condensation or icing) |
| Storage temperature | -40 to 70°C (with no condensation or icing) |
| Ambient operating humidity | 25% to 85% (with no condensation) |
| Storage humidity | 25% to 85% (with no condensation) |
| Altitude | 2,000 m max. |
| Terminal screw tightening torque | 0.54 Nm |
| Terminal wiring method | Recommended wire
Solid wire: 2.5 mm2 Twisted wires: AWG16, AWG18 Note: 1. Ferrules with insulating sleeves must be used with twisted wires. 2. Two wires can be twisted together. Recommended ferrules Al 1,5-8BK (for AWG16) manufactured by Phoenix Contact Al 1-8RD (for AWG18) manufactured by Phoenix Contact Al 0,75-8GY (for AWG18) manufactured by Phoenix Contact |
| Case color | Munsell 5Y8/1 |
| Case material | ABS resin (self-extinguishing resin) UL94-V0 |
| Weight | Approx. 110 g |
| Mounting | Mounted to DIN Track or via M4 screws (tightening torque: 1.2 Nm) |
| Dimensions | 22.5 (W) × 90 (H) × 100 (D) mm |
| Input voltage range | 200 to 500 VAC |
|---|---|
| Input frequency range | 45 to 65 Hz |
| Overload capacity | Continuous input: 115% of maximum input, 10 s max.: 125% of maximum input |
| Fixed Phase Asymmetry
Monitoring |
Output relay releases when one phase-phase voltage drops below 80% of the other
phase-phase voltage. |
| Temperature influence | Operating time
Fluctuation based on measured value at standard temperature: -20°C to standard temperature: ±10% max. Standard temperature to 60°C: ±10% max. (Humidity: 25% to 80%) |
| Humidity influence | Operating time
Based on ambient room humidity 25% to 80%: ±10% max. |
| Influence of power supply
voltage |
Operating time: ±10% max.
Note: The error in the operating value and operating time under standard conditions. |
| Influence of power supply
frequency |
Operating time: ±10% max. (at 45 to 65 Hz)
Note: The error in the operating value and operating time under standard conditions. |
| Influence of input
frequency |
At 45 to 65 Hz
Operating time: ±10% max. Note: The error in the operating value and operating time under standard conditions. |
| Insulation resistance | 20 MΩ min.
Between external terminals and case Between input terminals and output terminals |
| Dielectric strength | 2,000 VAC for one minute
Between external terminals and case Between input terminals and output terminals |
| Noise immunity | 1,500 V power supply terminal common/normal mode
Square-wave noise of ±1 μs/100 ns pulse width with 1-ns rise time |
| Vibration resistance | Frequency 10 to 55 Hz, 0.35-mm single amplitude, acceleration 50 m/s2
10 sweeps of 5 min each in X, Y, and Z directions |
| Shock resistance | 100 m/s2, 3 times each in 6 directions along three axes (up/down, left/right, forward/
backward) |
| Degree of protection | Terminal section: Finger protection |
last update: February 3, 2014