Item | G70A-ZOC16-3 | G70A-ZOC16-4 | G70A-ZIM16-5 |
---|---|---|---|
Contact resistance | 10 mΩ (excluding the resistance of the relay to be used) | ||
Permissible current | 10 A | 100 mA | |
Max. operating voltage | 380 VAC, 125 VDC | 30 VDC | |
Dielectric strength | 4,000 VAC, 50/60 Hz for 1 min between connector
and output terminals 2,000 VAC, 50/60 Hz for 1 min between output terminals 250 VAC, 50/60 Hz for 1 min between connectors |
4,000 VAC, 50/60 Hz for 1 min between
connector and input terminals 2,000 VAC, 50/60 Hz for 1 min between coil terminals 250 VAC, 50/60 Hz for 1 min between connectors |
|
Insulation resistance | Between connector and I/O terminals: 1,000 MΩ (at 500 V)
Other: 100 MΩ (at 500 V) |
||
Vibration resistance | Malfunction: 10 to 61.2 to 10 Hz, 0.1-mm single amplitude (0.2-mm double amplitude); 61.2 to
150 to 61.2 Hz, 14.7 m/s2 |
||
Shock resistance | Malfunction: 200 m/s2 | ||
Noise immunity | Noise level: 2.0 kV; pulse width: 100 ns to 1 μs | ||
Ambient temperature | Operating: 0 to 55°C (with no condensation or icing) | ||
Ambient humidity | Operating: 35% to 85% | ||
Coil surge absorption
element |
Diode: 1 A, 400 V | Varistor * | |
Protection diode for
inverse connection |
Diode (2 A, withstand inverse voltage: 40 V) | ||
Tensile strength | No damage when a tensile force of 49 N is applied for 1 second in any direction | ||
I/O terminal
tightening torque |
Tightening strength: 0.59 N·m;
Tensile strength 49 N for 1 min. |
||
Weight | Approx. 400 g |