Types | Quadruple distance model | ||||
---|---|---|---|---|---|
Size | M8 | M12 | M18 | M30 | |
Model | E2E-X4[]8 | E2E-X9[]12 | E2E-X14[]18 | E2E-X23[]30 | |
Sensing distance | 4 mm±10% | 9 mm±10% | 14 mm±10% | 23 mm±10% | |
Setting distance | 0 to 3 mm | 0 to 6.8 mm | 0 to 10.6 mm | 0 to 17.6 mm | |
Differential travel | 15% max. of sensing distance | ||||
Detectable object | Ferrous metals (For non-ferrous metals, refer to the Engineering Data on Catalog.) | ||||
Standard sensing object | Iron,
12 × 12 × 1 mm |
Iron,
27 × 27 × 1 mm |
Iron,
42 × 42 × 1 mm |
Iron,
69 × 69 × 1 mm |
|
Response frequency *1 | 700 Hz | 700 Hz | 350 Hz | 200 Hz | |
Power supply voltage | 10 to 30 VDC (including 10% ripple (p-p)), Class 2 | ||||
Current consumption | 1-output models: 16 mA max. | ||||
Output configuration | B[] Models: PNP open collector, C[] Models: NPN open collector | ||||
Operation mode
(with sensing object approaching) |
1-output models (B1, C1): NO (Normally open),
1-output models (B2, C2): NC (Normally closed) |
||||
Control
output |
Load current | 1-output models:
10 to 30 VDC, Class 2, 50 mA max. |
|||
Residual voltage | 1-output models:
2 V max. (Load current: 50 mA, Cable length: 2 m) |
||||
Indicator *2 | In the Standard I/O mode (SIO mode): Operation indicator (orange, lit) and
communication indicator (green, not lit) In the IO-Link communication mode (COM mode): Operation indicator (orange, lit) and communication indicator (green, blinking at 1 s intervals) |
||||
Protection circuits | Power supply reverse polarity protection, Surge suppressor, Output short-circuit
protection, Output reverse polarity protection |
||||
Ambient temperature range | Operating: -25 to 60°C
Storage: -25 to 70°C (with no icing or condensation) |
Operating/Storage: -25 to 70°C (with no icing or
condensation) |
|||
Ambient humidity range | Operating/Storage: 35% to 95% (with no condensation) | ||||
Temperature influence | -15% to 25% max. of
sensing distance at 23°C in the temperature range of -25 to 60°C |
±15% max. of sensing distance at 23°C in the temperature
range of -25 to 70°C |
|||
Voltage influence | ±1% max. of sensing distance at rated voltage in the rated voltage ±15% range | ||||
Insulation resistance | 50 MΩ min. (at 500 VDC) between current-carrying parts and case | ||||
Dielectric strength | 1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case | ||||
Vibration resistance
(destruction) |
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions | ||||
Shock resistance
(destruction) |
500 m/s2 10 times
each in X, Y, and Z directions |
1,000 m/s2 10 times each in X, Y, and Z directions | |||
Degree of protection | Pre-wired Models, Pre-wired Connector Models: IEC 60529: IP67, ISO 20653 (old
standard: DIN 40050 PART9): IP69K, JIS C 0920 Annex 1: IP67G, Passed OMRON's Oil-resistant Component Evaluation Standards *3 (Cutting oil type: specified in JIS K 2241: 2000; Temperature: 35°C max.) Connector Models: IEC 60529: IP67, ISO 20653 (old standard: DIN 40050 PART9): IP69K |
||||
Connection method | Pre-wired Models (Standard cable length: 2 m), Pre-wired Connector Models (Standard
cable length: 0.3 m) and Connector Models (M12 Connector, M8 (4-pin) Connector and M8 (3-pin) Connector) |
||||
Weight*4
(packed state) |
Pre-wired | Approx. 85 g | Approx. 95 g | Approx. 180 g | Approx. 260 g |
M12 Pre-wired
Smartclick Connector |
Approx. 55 g | Approx. 70 g | Approx. 115 g | Approx. 200 g | |
Connector | Approx. 40 g
(M8/M12 Connector) |
Approx. 55 g | Approx. 95 g | Approx. 180 g | |
Materials | Case | Nickel-plated brass | |||
Sensing surface | Polybutylene terephthalat (PBT) | ||||
Clamping nuts | Nickel-plated brass | ||||
Toothed washers | Zinc-plated iron | ||||
Cable | Vinyl chloride (PVC)
Note: Material of Pre-wired Models and Pre-wired Connector Models. |
||||
Main IO-Link functions*2 | Operation mode switching between NO and NC, self diagnosis enabling, excessive
proximity judgment distance selecting, timer function of the control output and timer time selecting, instability output (IO-Link mode) ON delay timer time selecting function, monitor output, operating hours read-out, readout of the sensor internal temperature, and initial reset |
||||
IO-Link
Commun- ication specifica- tions *2 |
IO-Link
specification |
Ver 1.1 | |||
Baud rate | COM2 (38.4 kbps), COM3 (230.4 kbps) | ||||
Data length | PD size: 2 bytes, OD size: 1 byte (M-sequence type: TYPE_2_2) | ||||
Minimum cycle
time |
COM2: 2.3 ms, COM3: 0.4 ms | ||||
Accessories | Instruction manual, Clamping nuts, Toothed washer |
Types | Triple distance model | ||||
---|---|---|---|---|---|
Size | M8 | M12 | M18 | M30 | |
Model | E2E-X3[]8 | E2E-X6[]12 | E2E-X12[]18 | E2E-X22[]30 | |
Sensing distance | 3 mm±10% | 6 mm±10% | 12 mm±10% | 22 mm±10% | |
Setting distance | 0 to 2.4 mm | 0 to 4.8 mm | 0 to 9.6 mm | 0 to 16.8 mm | |
Differential travel | 15% max. of sensing distance | ||||
Detectable object | Ferrous metals (For non-ferrous metals, refer to the Engineering Data on Catalog.) | ||||
Standard sensing object | Iron,
9 × 9 × 1 mm |
Iron,
18 × 18 × 1 mm |
Iron,
36 × 36 × 1 mm |
Iron,
66 × 66 × 1 mm |
|
Response frequency *1 | 1,000 Hz | 800 Hz | 500 Hz | 200 Hz | |
Power supply voltage | 10 to 30 VDC (including 10% ripple (p-p)), Class 2 | ||||
Current consumption | 1-output models:
16 mA max. |
1-output models: 16 mA max.,
2-output models: 20 mA max. |
|||
Output configuration | B[] Models: PNP open collector, C[] Models: NPN open collector | ||||
Operation mode
(with sensing object approaching) |
1-output models (B1,
C1): NO (Normally open), 1-output models (B2, C2): NC (Normally closed) |
1-output models (B1, C1): NO (Normally open),
1-output models (B2, C2): NC (Normally closed), 2-output models (B3, C3): NO+NC (Normally open, Normally closed) |
|||
Control
output |
Load current | 1-output models:
10 to 30 VDC, Class 2, 100 mA max. |
1-output models:
10 to 30 VDC, Class 2, 100 mA max., 2-output models: 10 to 30 VDC, Class 2, 50 mA max. |
||
Residual voltage | 1-output models: 2 V
max. (Load current: 100 mA, Cable length: 2 m) |
1-output models:
2 V max. (Load current: 100 mA, Cable length: 2 m), 2-output models: 2 V max. (Load current: 50 mA, Cable length: 2 m) |
|||
Indicator *2 | In the Standard I/O mode (SIO mode): Operation indicator (orange, lit) and
communication indicator (green, not lit) In the IO-Link communication mode (COM mode): Operation indicator (orange, lit) and communication indicator (green, blinking at 1 s intervals) |
||||
Protection circuits | Power supply reverse polarity protection, Surge suppressor, Output short-circuit
protection, Output reverse polarity protection |
||||
Ambient temperature range | Operating/Storage: -25 to 70°C (with no icing or condensation) | ||||
Ambient humidity range | Operating/Storage: 35% to 95% (with no condensation) | ||||
Temperature influence | ±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C | ||||
Voltage influence | ±1% max. of sensing distance at rated voltage in the rated voltage ±15% range | ||||
Insulation resistance | 50 MΩ min. (at 500 VDC) between current-carrying parts and case | ||||
Dielectric strength | 1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case | ||||
Vibration resistance
(destruction) |
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions | ||||
Shock resistance
(destruction) |
500 m/s2 10 times
each in X, Y, and Z directions |
1,000 m/s2 10 times each in X, Y, and Z directions | |||
Degree of protection | Pre-wired Models, Pre-wired Connector Models: IEC 60529: IP67, ISO 20653 (old
standard: DIN 40050 PART9): IP69K, JIS C 0920 Annex 1: IP67G, Passed OMRON's Oil-resistant Component Evaluation Standards *3 (Cutting oil type: specified in JIS K 2241: 2000; Temperature: 35°C max.) Connector Models: IEC 60529: IP67, ISO 20653 (old standard: DIN 40050 PART9): IP69K |
||||
Connection method | Pre-wired Models (Standard cable length: 2 m), Pre-wired Connector Models (Standard
cable length: 0.3 m) and Connector Models (M12 Connector, M8 (4-pin) Connector and M8 (3-pin) Connector) |
||||
Weight*4
(packed state) |
Pre-wired | Approx. 85 g | Approx. 95 g | Approx. 180 g | Approx. 260 g |
M12 Pre-wired
Smartclick Connector |
Approx. 55 g | Approx. 70 g | Approx. 115 g | Approx. 200 g | |
Connector | Approx. 40 g
(M8/M12 Connector) |
Approx. 55 g | Approx. 95 g | Approx. 180 g | |
Materials | Case | Nickel-plated brass | |||
Sensing surface | Polybutylene terephthalat (PBT) | ||||
Clamping nuts | Nickel-plated brass | ||||
Toothed washers | Zinc-plated iron | ||||
Cable | Vinyl chloride (PVC)
Note: Material of Pre-wired Models and Pre-wired Connector Models. |
||||
Main IO-Link functions*2 | Operation mode switching between NO and NC, self diagnosis enabling, excessive
proximity judgment distance selecting, timer function of the control output and timer time selecting, instability output (IO-Link mode) ON delay timer time selecting function, monitor output, operating hours read-out, readout of the sensor internal temperature, and initial reset |
||||
IO-Link
Commun- ication specifica- tions *2 |
IO-Link
specification |
Ver 1.1 | |||
Baud rate | COM2 (38.4 kbps), COM3 (230.4 kbps) | ||||
Data length | PD size: 2 bytes, OD size: 1 byte (M-sequence type: TYPE_2_2) | ||||
Minimum cycle
time |
COM2: 2.3 ms, COM3: 0.4 ms | ||||
Accessories | Instruction manual, Clamping nuts, Toothed washer |
Types | Quadruple distance model | ||||
---|---|---|---|---|---|
Size | M8 | M12 | M18 | M30 | |
Model | E2E-X8M[]8 | E2E-X16M[]12 | E2E-X30M[]18 | E2E-X50M[]30 | |
Sensing distance | 8 mm±10% | 16 mm±10% | 30 mm±10% | 50 mm±10% | |
Setting distance | 0 to 6 mm | 0 to 12.2 mm | 0 to 23 mm | 0 to 38.2 mm | |
Differential travel | 15% max. of sensing distance | ||||
Detectable object | Ferrous metals (For non-ferrous metals, refer to the Engineering Data on Catalog.) | ||||
Standard sensing object | Iron,
24 × 24 × 1 mm |
Iron,
48 × 48 × 1 mm |
Iron,
90 × 90 × 1 mm |
Iron,
150 × 150 × 1 mm |
|
Response frequency *1 | 500 Hz | 400 Hz | 200 Hz | 100 Hz | |
Power supply voltage | 10 to 30 VDC (including 10% ripple (p-p)), Class 2 | ||||
Current consumption | 1-output models: 16 mA max. | ||||
Output configuration | B[] Models: PNP open collector
C[] Models: NPN open collector |
||||
Operation mode
(with sensing object approaching) |
1-output models (B1, C1): NO (Normally open),
1-output models (B2, C2): NC (Normally closed) |
||||
Control
output |
Load current | 1-output models:
10 to 30 VDC, Class 2, 50 mA max. |
|||
Residual voltage | 1-output models:
2 V max. (Load current: 50 mA, Cable length: 2 m) |
||||
Indicator *2 | In the Standard I/O mode (SIO mode): Operation indicator (orange, lit) and
communication indicator (green, not lit) In the IO-Link communication mode (COM mode): Operation indicator (orange, lit) and communication indicator (green, blinking at 1 s intervals) |
||||
Protection circuits | Power supply reverse polarity protection, Surge suppressor, Output short-circuit
protection, Output reverse polarity protection |
||||
Ambient temperature range | Operating/Storage: -25 to 70°C (with no icing or condensation) | ||||
Ambient humidity range | Operating/Storage: 35% to 95% (with no condensation) | ||||
Temperature influence | ±15% max. of sensing distance at 23°C in the temperature range of -25 to 70°C | ||||
Voltage influence | ±1% max. of sensing distance at rated voltage in the rated voltage ±15% range | ||||
Insulation resistance | 50 MΩ min. (at 500 VDC) between current-carrying parts and case | ||||
Dielectric strength | 1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case | ||||
Vibration resistance
(destruction) |
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions | ||||
Shock resistance
(destruction) |
500 m/s2 10 times
each in X, Y, and Z directions |
1,000 m/s2 10 times each in X, Y, and Z directions | |||
Degree of protection | Pre-wired Models, Pre-wired Connector Models: IEC 60529:IP67, ISO 20653 (old
standard: DIN 40050 PART9): IP69K, JIS C 0920 Annex 1: IP67G, Passed OMRON's Oil-resistant Component Evaluation Standards *3 (Cutting oil type: specified in JIS K 2241: 2000; Temperature: 35°C max.) Connector Models: IEC 60529: IP67, ISO 20653 (old standard: DIN 40050 PART9): IP69K |
||||
Connection method | Pre-wired Models (Standard cable length: 2 m), Pre-wired Connector Models
(Standard cable length: 0.3 m) and Connector Models (M12 Connector, M8 (4-pin) Connector and M8 (3-pin) Connector) |
||||
Weight*4
(packed state) |
Pre-wired | Approx. 85 g | Approx. 95 g | Approx. 190 g | Approx. 310 g |
M12 Pre-wired
Smartclick Connector |
Approx. 55 g | Approx. 70 g | Approx. 125 g | Approx. 250 g | |
Connector | Approx. 40 g
(M8/M12 Connector) |
Approx. 55 g | Approx. 105 g | Approx. 230 g | |
Materials | Case | Stainless (SUS303) | Nickel-plated brass | ||
Sensing surface | Polybutylene terephthalat (PBT) | ||||
Clamping nuts | Nickel-plated brass | ||||
Toothed washers | Zinc-plated iron | ||||
Cable | Vinyl chloride (PVC)
Note: Material of Pre-wired Models and Pre-wired Connector Models. |
||||
Main IO-Link functions*2 | Operation mode switching between NO and NC, self diagnosis enabling, excessive
proximity judgment distance selecting, timer function of the control output and timer time selecting, instability output (IO-Link mode) ON delay timer time selecting function, monitor output, operating hours read-out, readout of the sensor internal temperature, and initial reset |
||||
IO-Link
Commun- ication specifica- tions *2 |
IO-Link
specification |
Ver1.1 | |||
Baud rate | COM2 (38.4 kbps), COM3 (230.4 kbps) | ||||
Data length | PD size: 2 bytes, OD size: 1 byte (M-sequence type: TYPE_2_2) | ||||
Minimum cycle
time |
COM2: 2.3 ms, COM3: 0.4 ms | ||||
Accessories | Instruction manual, Clamping nuts, Toothed washer |
Types | Triple distance model | ||||
---|---|---|---|---|---|
Size | M8 | M12 | M18 | M30 | |
Model | E2E-X6M[]8 | E2E-X10M[]12 | E2E-X20M[]18 | E2E-X40M[]30 | |
Sensing distance | 6 mm±10% | 10 mm±10% | 20 mm±10% | 40 mm±10% | |
Setting distance | 0 to 4.8 mm | 0 to 8 mm | 0 to 16 mm | 0 to 32 mm | |
Differential travel | 15% max. of sensing distance | ||||
Detectable object | Ferrous metals (For non-ferrous metals, refer to the Engineering Data on Catalog.) | ||||
Standard sensing object | Iron,
18 × 18 × 1 mm |
Iron,
30 × 30 × 1 mm |
Iron,
60 × 60 × 1 mm |
Iron,
120 × 120 × 1 mm |
|
Response frequency *1 | 800 Hz | 400 Hz | 200 Hz | 100 Hz | |
Power supply voltage | 10 to 30 VDC (including 10% ripple (p-p)), Class 2 | ||||
Current consumption | 1-output models:
16 mA max. |
1-output models: 16 mA max.,
2-output models: 20 mA max. |
|||
Output configuration | B[] Models: PNP open collector
C[] Models: NPN open collector |
||||
Operation mode
(with sensing object approaching) |
1-output models (B1,
C1): NO (Normally open), 1-output models (B2, C2): NC (Normally closed) |
1-output models (B1, C1): NO (Normally open),
1-output models (B2, C2): NC (Normally closed), 2-output models (B3, C3): NO+NC (Normally open, Normally closed) |
|||
Control
output |
Load current | 1-output models:
10 to 30 VDC, Class 2, 100 mA max. |
1-output models: 10 to 30 VDC, Class 2, 100 mA max.,
2-output models: 10 to 30 VDC, Class 2, 50 mA max. |
||
Residual voltage | 1-output models: 2 V
max. (Load current: 100 mA, Cable length: 2 m) |
1-output models:
2 V max. (Load current: 100 mA, Cable length: 2 m), 2-output models: 2 V max. (Load current: 50 mA, Cable length: 2 m) |
|||
Indicator *2 | In the Standard I/O mode (SIO mode): Operation indicator (orange, lit) and
communication indicator (green, not lit) In the IO-Link communication mode (COM mode): Operation indicator (orange, lit) and communication indicator (green, blinking at 1 s intervals) |
||||
Protection circuits | Power supply reverse polarity protection, Surge suppressor, Output short-circuit
protection, Output reverse polarity protection |
||||
Ambient temperature range | Operating/Storage: -25 to 70°C (with no icing or condensation) | ||||
Ambient humidity range | Operating/Storage: 35% to 95% (with no condensation) | ||||
Temperature influence | ±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C | ||||
Voltage influence | ±1% max. of sensing distance at rated voltage in the rated voltage ±15% range | ||||
Insulation resistance | 50 MΩ min. (at 500 VDC) between current-carrying parts and case | ||||
Dielectric strength | 1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case | ||||
Vibration resistance
(destruction) |
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions | ||||
Shock resistance
(destruction) |
500 m/s2 10 times
each in X, Y, and Z directions |
1,000 m/s2 10 times each in X, Y, and Z directions | |||
Degree of protection | Pre-wired Models, Pre-wired Connector Models: IEC 60529:IP67, ISO 20653 (old
standard: DIN 40050 PART9): IP69K, JIS C 0920 Annex 1: IP67G, Passed OMRON's Oil-resistant Component Evaluation Standards *3 (Cutting oil type: specified in JIS K 2241: 2000; Temperature: 35°C max.) Connector Models: IEC 60529: IP67, ISO 20653 (old standard: DIN 40050 PART9): IP69K |
||||
Connection method | Pre-wired Models (Standard cable length: 2 m), Pre-wired Connector Models
(Standard cable length: 0.3 m) and Connector Models (M12 Connector, M8 (4-pin) Connector and M8 (3-pin) Connector) |
||||
Weight*4
(packed state) |
Pre-wired | Approx. 85 g | Approx. 95 g | Approx. 190 g | Approx. 280 g |
M12 Pre-wired
Smartclick Connector |
Approx. 55 g | Approx. 70 g | Approx. 125 g | Approx. 220 g | |
Connector | Approx. 40 g
(M8/M12 Connector) |
Approx. 55 g | Approx. 105 g | Approx. 200 g | |
Materials | Case | Stainless (SUS303) | Nickel-plated brass | ||
Sensing surface | Polybutylene terephthalat (PBT) | ||||
Clamping nuts | Nickel-plated brass | ||||
Toothed washers | Zinc-plated iron | ||||
Cable | Vinyl chloride (PVC)
Note: Material of Pre-wired Models and Pre-wired Connector Models. |
||||
Main IO-Link functions*2 | Operation mode switching between NO and NC, self diagnosis enabling, excessive
proximity judgment distance selecting, timer function of the control output and timer time selecting, instability output (IO-Link mode) ON delay timer time selecting function, monitor output, operating hours read-out, readout of the sensor internal temperature, and initial reset |
||||
IO-Link
Commun- ication specifica- tions *2 |
IO-Link
specification |
Ver1.1 | |||
Baud rate | COM2 (38.4 kbps), COM3 (230.4 kbps) | ||||
Data length | PD size: 2 bytes, OD size: 1 byte (M-sequence type: TYPE_2_2) | ||||
Minimum cycle
time |
COM2: 2.3 ms, COM3: 0.4 ms | ||||
Accessories | Instruction manual, Clamping nuts, Toothed washer |
Types | Double distance model | ||||
---|---|---|---|---|---|
Size | M8 | M12 | M18 | M30 | |
Model | E2E-X2[]8 | E2E-X4[]12 | E2E-X8[]18 | E2E-X15[]30 | |
Sensing distance | 2 mm±10% | 4 mm±10% | 8 mm±10% | 15 mm±10% | |
Setting distance | 0 to 1.6 mm | 0 to 3.2 mm | 0 to 6.4 mm | 0 to 12 mm | |
Differential travel | 15% max. of sensing distance | ||||
Detectable object | Ferrous metals (For non-ferrous metals, refer to the Engineering Data on Catalog.) | ||||
Standard sensing object | Iron,
8 × 8 × 1 mm |
Iron,
12 × 12 × 1 mm |
Iron,
24 × 24 × 1 mm |
Iron,
45 × 45 × 1 mm |
|
Response frequency *1 | 1,500 Hz | 1,000 Hz | 500 Hz | 250 Hz | |
Power supply voltage | 10 to 30 VDC (including 10% ripple (p-p)), Class 2 | ||||
Current consumption | 1-output models: 16 mA max.
2-output models: 20 mA max. |
||||
Output configuration | B[] Models: PNP open collector
C[] Models: NPN open collector |
||||
Operation mode
(with sensing object approaching) |
1-output models (B1, C1): NO (Normally open),
1-output models (B2, C2): NC (Normally closed), 2-output models (B3, C3): NO+NC (Normally open, Normally closed) *3 |
||||
Control
output |
Load current | 1-output models:
10 to 30 VDC, Class 2, 200 mA max., (-40 to 70°C), 100 mA max., (70 to 85°C) 2-output models: 10 to 30 VDC, Class 2, 50 mA max. |
1-output models:
10 to 30 VDC, Class 2, 200 mA max., 2-output models: 10 to 30 VDC, Class 2, 100 mA max. |
||
Residual voltage | 1-output models:
2 V max. (Load current: 200 mA, Cable length: 2 m), 2-output models: 2 V max. (Load current: 50 mA, Cable length: 2 m) |
1-output models:
2 V max. (Load current: 200 mA, Cable length: 2 m), 2-output models: 2 V max. (Load current: 100 mA, Cable length: 2 m) |
|||
Indicator *2 | In the Standard I/O mode (SIO mode): Operation indicator (orange, lit) and
communication indicator (green, not lit) In the IO-Link communication mode (COM mode): Operation indicator (orange, lit) and communication indicator (green, blinking at 1 s intervals) |
||||
Protection circuits | Power supply reverse polarity protection, Surge suppressor, Output short-circuit
protection, Output reverse polarity protection |
||||
Ambient temperature range | Operating/Storage: -40 to 85°C (with no icing or condensation)
Note: The UL temperature rating for M12 Pre-wired Connector Models is -25 to 70°C. |
||||
Ambient humidity range | Operating/Storage: 35% to 95% (with no condensation) | ||||
Temperature influence | ±15% max. of sensing distance at 23°C in the temperature range of -40 to 85°C
±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C |
||||
Voltage influence | ±1% max. of sensing distance at rated voltage in the rated voltage ±15% range | ||||
Insulation resistance | 50 MΩ min. (at 500 VDC) between current-carrying parts and case | ||||
Dielectric strength | 1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case | ||||
Vibration resistance
(destruction) |
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions | ||||
Shock resistance
(destruction) |
500 m/s2 10 times
each in X, Y, and Z directions |
1,000 m/s2 10 times each in X, Y, and Z directions | |||
Degree of protection | Pre-wired Models, Pre-wired Connector Models: IEC 60529:IP67, ISO 20653 (old
standard: DIN 40050 PART9): IP69K, JIS C 0920 Annex 1: IP67G, Passed OMRON's Oil-resistant Component Evaluation Standards *4 (Cutting oil type: specified in JIS K 2241:2000; Temperature: 35°C max.) Connector Models: IEC 60529: IP67, ISO 20653 (old standard: DIN 40050 PART9): IP69K |
||||
Connection method | Pre-wired Models (Standard cable length: 2 m), Pre-wired Connector Models
(Standard cable length: 0.3 m) and Connector Models (M12 Connector, M8 (4-pin) Connector and M8 (3-pin) Connector) |
||||
Weight *5
(packed state) |
Pre-wired | Approx. 85 g | Approx. 95 g | Approx. 170 g | Approx. 240 g |
M12 Pre-wired
Smartclick Connector |
Approx. 55 g | Approx. 70 g | Approx. 105 g | Approx. 170 g | |
Connector | Approx. 40 g
(M8/M12 Connector) |
Approx. 55 g | Approx. 85 g | Approx. 160 g | |
Materials | Case | Stainless (SUS303) | Nickel-plated brass | ||
Sensing surface | Polybutylene terephthalat (PBT) | ||||
Clamping nuts | Nickel-plated brass | ||||
Toothed washers | Zinc-plated iron | ||||
Cable | Vinyl chloride (PVC)
Note: Material of Pre-wired Models and Pre-wired Connector Models. |
||||
Main IO-Link functions *2 | Operation mode switching between NO and NC, self diagnosis enabling, excessive
proximity judgment distance selecting, timer function of the control output and timer time selecting, instability output (IO-Link mode) ON delay timer time selecting function, monitor output, operating hours read-out, readout of the sensor internal temperature, and initial reset |
||||
IO-Link
Commun- ication specifica- tions *2 |
IO-Link
specification |
Ver1.1 | |||
Baud rate | COM2 (38.4 kbps), COM3 (230.4 kbps) | ||||
Data length | PD size: 2 bytes, OD size: 1 byte (M-sequence type: TYPE_2_2) | ||||
Minimum cycle
time |
COM2: 2.3 ms, COM3: 0.4 ms | ||||
Accessories | Instruction manual, Clamping nuts, Toothed washer |
Types | Single distance model | ||||
---|---|---|---|---|---|
Size | M8 | M12 | M18 | M30 | |
Model | E2E-X1R5[]8 | E2E-X2[]12 | E2E-X5[]18 | E2E-X10[]30 | |
Sensing distance | 1.5 mm±10% | 2 mm±10% | 5 mm±10% | 10 mm±10% | |
Setting distance | 0 to 1.2 mm | 0 to 1.6 mm | 0 to 4 mm | 0 to 8 mm | |
Differential travel | 10% max. of sensing distance | ||||
Detectable object | Ferrous metals (For non-ferrous metals, refer to the Engineering Data on Catalog.) | ||||
Standard sensing object | Iron,
8 × 8 × 1 mm |
Iron,
12 × 12 × 1 mm |
Iron,
18 × 18 × 1 mm |
Iron,
30 × 30 × 1 mm |
|
Response frequency *1 | 2,000 Hz | 1,500 Hz | 600 Hz | 400 Hz | |
Power supply voltage | 10 to 30 VDC (including 10% ripple (p-p)), Class 2 | ||||
Current consumption | 1-output models: 16 mA max.
2-output models: 20 mA max. |
||||
Output configuration | B[] Models: PNP open collector
C[] Models: NPN open collector |
||||
Operation mode
(with sensing object approaching) |
1-output models (B1, C1): NO (Normally open),
1-output models (B2, C2): NC (Normally closed), 2-output models (B3, C3): NO+NC (Normally open, Normally closed) *3 |
||||
Control
output |
Load current | 1-output models:
10 to 30 VDC, Class 2, 200 mA max., (-40 to 70°C), 100 mA max., (70 to 85°C) 2-output models: 10 to 30 VDC, Class 2, 50 mA max. |
1-output models:
10 to 30 VDC, Class 2, 200 mA max., 2-output models: 10 to 30 VDC, Class 2, 100 mA max. |
||
Residual voltage | 1-output models:
2 V max. (Load current: 200 mA, Cable length: 2 m), 2-output models: 2 V max. (Load current: 50 mA, Cable length: 2 m) |
1-output models:
2 V max. (Load current: 200 mA, Cable length: 2 m), 2-output models: 2 V max. (Load current: 100 mA, Cable length: 2 m) |
|||
Indicator *2 | In the Standard I/O mode (SIO mode): Operation indicator (orange, lit) and
communication indicator (green, not lit) In the IO-Link communication mode (COM mode): Operation indicator (orange, lit) and communication indicator (green, blinking at 1 s intervals) |
||||
Protection circuits | Power supply reverse polarity protection, Surge suppressor, Output short-circuit
protection, Output reverse polarity protection |
||||
Ambient temperature range | Operating/Storage: -40 to 85°C (with no icing or condensation)
Note: The UL temperature rating for M12 Pre-wired Connector Models is -25 to 70°C. |
||||
Ambient humidity range | Operating/Storage: 35% to 95% (with no condensation) | ||||
Temperature influence | ±15% max. of sensing distance at 23°C in the temperature range of -40 to 85°C
±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C |
||||
Voltage influence | ±1% max. of sensing distance at rated voltage in the rated voltage ±15% range | ||||
Insulation resistance | 50 MΩ min. (at 500 VDC) between current-carrying parts and case | ||||
Dielectric strength | 1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case | ||||
Vibration resistance
(destruction) |
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions | ||||
Shock resistance
(destruction) |
500 m/s2 10 times
each in X, Y, and Z directions |
1,000 m/s2 10 times each in X, Y, and Z directions | |||
Degree of protection | Pre-wired Models, Pre-wired Connector Models: IEC 60529:IP67, ISO 20653 (old
standard: DIN 40050 PART9): IP69K, JIS C 0920 Annex 1: IP67G, Passed OMRON's Oil-resistant Component Evaluation Standards *4 (Cutting oil type: specified in JIS K 2241:2000; Temperature: 35°C max.) Connector Models: IEC 60529: IP67, ISO 20653 (old standard: DIN 40050 PART9): IP69K |
||||
Connection method | Pre-wired Models (Standard cable length: 2 m), Pre-wired Connector Models
(Standard cable length: 0.3 m) and Connector Models (M12 Connector, M8 (4-pin) Connector and M8 (3-pin) Connector) |
||||
Weight *5
(packed state) |
Pre-wired | Approx. 85 g | Approx. 95 g | Approx. 170 g | Approx. 240 g |
M12 Pre-wired
Smartclick Connector |
Approx. 55 g | Approx. 70 g | Approx. 105 g | Approx. 170 g | |
Connector | Approx. 40 g
(M8/M12 Connector) |
Approx. 55 g | Approx. 85 g | Approx. 160 g | |
Materials | Case | Stainless (SUS303) | Nickel-plated brass | ||
Sensing surface | Polybutylene terephthalat (PBT) | ||||
Clamping nuts | Nickel-plated brass | ||||
Toothed washers | Zinc-plated iron | ||||
Cable | Vinyl chloride (PVC)
Note: Material of Pre-wired Models and Pre-wired Connector Models. |
||||
Main IO-Link functions *2 | Operation mode switching between NO and NC, self diagnosis enabling, excessive
proximity judgment distance selecting, timer function of the control output and timer time selecting, instability output (IO-Link mode) ON delay timer time selecting function, monitor output, operating hours read-out, readout of the sensor internal temperature, and initial reset |
||||
IO-Link
Commun- ication specifica- tions *2 |
IO-Link
specification |
Ver1.1 | |||
Baud rate | COM2 (38.4 kbps), COM3 (230.4 kbps) | ||||
Data length | PD size: 2 bytes, OD size: 1 byte (M-sequence type: TYPE_2_2) | ||||
Minimum cycle
time |
COM2: 2.3 ms, COM3: 0.4 ms | ||||
Accessories | Instruction manual, Clamping nuts, Toothed washer |
Types | Double distance model | ||||
---|---|---|---|---|---|
Size | M8 | M12 | M18 | M30 | |
Model | E2E-X4M[]8 | E2E-X8M[]12 | E2E-X16M[]18 | E2E-X30M[]30 | |
Sensing distance | 4 mm±10% | 8 mm±10% | 16 mm±10% | 30 mm±10% | |
Setting distance | 0 to 3.2 mm | 0 to 6.4 mm | 0 to 12.8 mm | 0 to 24 mm | |
Differential travel | 15% max. of sensing distance | ||||
Detectable object | Ferrous metals (For non-ferrous metals, refer to the Engineering Data on Catalog.) | ||||
Standard sensing object | Iron,
12 × 12 × 1 mm |
Iron,
24 × 24 × 1 mm |
Iron,
48 × 48 × 1 mm |
Iron,
90 × 90 × 1 mm |
|
Response frequency *1 | 1,000 Hz | 800 Hz | 400 Hz | 100 Hz | |
Power supply voltage | 10 to 30 VDC (including 10% ripple (p-p)), Class 2 | ||||
Current consumption | 1-output models: 16 mA max.
2-output models: 20 mA max. |
||||
Output configuration | B[] Models: PNP open collector
C[] Models: NPN open collector |
||||
Operation mode
(with sensing object approaching) |
1-output models (B1, C1): NO (Normally open),
1-output models (B2, C3): NC (Normally closed) 2-output models (B3, C3): NO+NC (Normally open, Normally closed) *3 |
||||
Control
output |
Load current | 1-output models:
10 to 30 VDC, Class 2, 200 mA max., (-40 to 70°C), 100 mA max., (70 to 85°C) 2-output models: 10 to 30 VDC, Class 2, 50 mA max. |
1-output models:
10 to 30 VDC, Class 2, 200 mA max., 2-output models: 10 to 30 VDC, Class 2, 100 mA max. |
||
Residual voltage | 1-output models:
2 V max. (Load current: 200 mA, Cable length: 2 m), 2-output models: 2 V max. (Load current: 50 mA, Cable length: 2 m) |
1-output models:
2 V max. (Load current: 200 mA, Cable length: 2 m), 2-output models: 2 V max. (Load current: 100 mA, Cable length: 2 m) |
|||
Indicator *2 | In the Standard I/O mode (SIO mode): Operation indicator (orange, lit) and
communication indicator (green, not lit) In the IO-Link communication mode (COM mode): Operation indicator (orange, lit) and communication indicator (green, blinking at 1 s intervals) |
||||
Protection circuits | Power supply reverse polarity protection, Surge suppressor, Output short-circuit
protection, Output reverse polarity protection |
||||
Ambient temperature range | Operating/Storage: -40 to 85°C (with no icing or condensation)
Note: The UL temperature rating for M12 Pre-wired Connector Models is -25 to 70°C. |
||||
Ambient humidity range | Operating/Storage: 35% to 95% (with no condensation) | ||||
Temperature influence | ±15% max. of sensing distance at 23°C in the temperature range of -40 to 85°C
±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C |
||||
Voltage influence | ±1% max. of sensing distance at rated voltage in the rated voltage ±15% range | ||||
Insulation resistance | 50 MΩ min. (at 500 VDC) between current-carrying parts and case | ||||
Dielectric strength | 1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case | ||||
Vibration resistance
(destruction) |
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions | ||||
Shock resistance
(destruction) |
500 m/s2 10 times
each in X, Y, and Z directions |
1,000 m/s2 10 times each in X, Y, and Z directions | |||
Degree of protection | Pre-wired Models, Pre-wired Connector Models: IEC 60529:IP67, ISO 20653 (old
standard: DIN 40050 PART9): IP69K, JIS C 0920 Annex 1: IP67G, Passed OMRON's Oil-resistant Component Evaluation Standards *4 (Cutting oil type: specified in JIS K 2241:2000; Temperature: 35°C max.) Connector Models: IEC 60529:IP67, ISO 20653 (old standard: DIN 40050 PART9): IP69K |
||||
Connection method | Pre-wired Models (Standard cable length: 2 m), Pre-wired Connector Models
(Standard cable length: 0.3 m) and Models (M12 Connector, M8 (4-pin) Connector and M8 (3-pin) Connector) |
||||
Weight *5
(packed state) |
Pre-wired | Approx. 85 g | Approx. 95 g | Approx. 170 g | Approx. 280 g |
M12 Pre-wired
Smartclick Connector |
Approx. 55 g | Approx. 70 g | Approx. 105 g | Approx. 220 g | |
Connector | Approx. 40 g
(M8/M12 Connector) |
Approx. 55 g | Approx. 85 g | Approx. 200 g | |
Materials | Case | Stainless (SUS303) | Nickel-plated brass | ||
Sensing surface | Polybutylene terephthalat (PBT) | ||||
Clamping nuts | Nickel-plated brass | ||||
Toothed washers | Zinc-plated iron | ||||
Cable | Vinyl chloride (PVC)
Note: Material of Pre-wired Models and Pre-wired Connector Models. |
||||
Main IO-Link functions *2 | Operation mode switching between NO and NC, self diagnosis enabling, excessive
proximity judgment distance selecting, timer function of the control output and timer time selecting, instability output (IO-Link mode) ON delay timer time selecting function, monitor output, operating hours read-out, readout of the sensor internal temperature, and initial reset |
||||
IO-Link
Commun- ication specifica- tions *2 |
IO-Link
specification |
Ver 1.1 | |||
Baud rate | COM2 (38.4 kbps), COM3 (230.4 kbps) | ||||
Data length | PD size: 2 bytes, OD size: 1 byte (M-sequence type: TYPE_2_2) | ||||
Minimum cycle
time |
COM2: 2.3 ms, COM3: 0.4 ms | ||||
Accessories | Instruction manual, Clamping nuts, Toothed washer |
Types | Single distance model | ||||
---|---|---|---|---|---|
Size | M8 | M12 | M18 | M30 | |
Model | E2E-X2M[]8 | E2E-X5M[]12 | E2E-X10M[]18 | E2E-X18M[]30 | |
Sensing distance | 2 mm±10% | 5 mm±10% | 10 mm±10% | 18 mm±10% | |
Setting distance | 0 to 1.6 mm | 0 to 4 mm | 0 to 8 mm | 0 to 14.4 mm | |
Differential travel | 10% max. of sensing distance | ||||
Detectable object | Ferrous metals (For non-ferrous metals, refer to the Engineering Data on Catalog.) | ||||
Standard sensing object | Iron,
8 × 8 × 1 mm |
Iron,
15 × 15 × 1 mm |
Iron,
30 × 30 × 1 mm |
Iron,
54 × 54 × 1 mm |
|
Response frequency *1 | 1,000 Hz | 800 Hz | 400 Hz | 100 Hz | |
Power supply voltage | 10 to 30 VDC (including 10% ripple (p-p)), Class 2 | ||||
Current consumption | 1-output models: 16 mA max.
2-output models: 20 mA max. |
||||
Output configuration | B[] Models: PNP open collector
C[] Models: NPN open collector |
||||
Operation mode
(with sensing object approaching) |
1-output models (B1, C1): NO (Normally open),
1-output models (B2, C3): NC (Normally closed) 2-output models (B3, C3): NO+NC (Normally open, Normally closed) *3 |
||||
Control
output |
Load current | 1-output models:
10 to 30 VDC, Class 2, 200 mA max., (-40 to 70°C), 100 mA max., (70 to 85°C) 2-output models: 10 to 30 VDC, Class 2, 50 mA max. |
1-output models:
10 to 30 VDC, Class 2, 200 mA max., 2-output models: 10 to 30 VDC, Class 2, 100 mA max. |
||
Residual voltage | 1-output models:
2 V max. (Load current: 200 mA, Cable length: 2 m), 2-output models: 2 V max. (Load current: 50 mA, Cable length: 2 m) |
1-output models:
2 V max. (under load current of 200 mA with cable length of 2 m), 2-output models: 2 V max. (under load current of 100 mA with cable length of 2 m) |
|||
Indicator *2 | In the Standard I/O mode (SIO mode): Operation indicator (orange, lit) and
communication indicator (green, not lit) In the IO-Link communication mode (COM mode): Operation indicator (orange, lit) and communication indicator (green, blinking at 1 s intervals) |
||||
Protection circuits | Power supply reverse polarity protection, Surge suppressor, Output short-circuit
protection, Output reverse polarity protection |
||||
Ambient temperature range | Operating/Storage: -40 to 85°C (with no icing or condensation)
Note: The UL temperature rating for M12 Pre-wired Connector Models is -25 to 70°C. |
||||
Ambient humidity range | Operating/Storage: 35% to 95% (with no condensation) | ||||
Temperature influence | ±15% max. of sensing distance at 23°C in the temperature range of -40 to 85°C
±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C |
||||
Voltage influence | ±1% max. of sensing distance at rated voltage in the rated voltage ±15% range | ||||
Insulation resistance | 50 MΩ min. (at 500 VDC) between current-carrying parts and case | ||||
Dielectric strength | 1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case | ||||
Vibration resistance
(destruction) |
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions | ||||
Shock resistance
(destruction) |
500 m/s2 10 times
each in X, Y, and Z directions |
1,000 m/s2 10 times each in X, Y, and Z directions | |||
Degree of protection | Pre-wired Models, Pre-wired Connector Models: IEC 60529:IP67, ISO 20653 (old
standard: DIN 40050 PART9): IP69K, JIS C 0920 Annex 1: IP67G, Passed OMRON's Oil-resistant Component Evaluation Standards *4 (Cutting oil type: specified in JIS K 2241:2000; Temperature: 35°C max.) Connector Models: IEC 60529:IP67, ISO 20653 (old standard: DIN 40050 PART9): IP69K |
||||
Connection method | Pre-wired Models (Standard cable length: 2 m), Pre-wired Connector Models
(Standard cable length: 0.3 m) and Models (M12 Connector, M8 (4-pin) Connector and M8 (3-pin) Connector) |
||||
Weight *5
(packed state) |
Pre-wired | Approx. 85 g | Approx. 95 g | Approx. 170 g | Approx. 240 g |
M12 Pre-wired
Smartclick Connector |
Approx. 55 g | Approx. 70 g | Approx. 105 g | Approx. 170 g | |
Connector | Approx. 40 g
(M8/M12 Connector) |
Approx. 55 g | Approx. 85 g | Approx. 160 g | |
Materials | Case | Stainless (SUS303) | Nickel-plated brass | ||
Sensing surface | Polybutylene terephthalat (PBT) | ||||
Clamping nuts | Nickel-plated brass | ||||
Toothed washers | Zinc-plated iron | ||||
Cable | Vinyl chloride (PVC)
Note: Material of Pre-wired Models and Pre-wired Connector Models. |
||||
Main IO-Link functions *2 | Operation mode switching between NO and NC, self diagnosis enabling, excessive
proximity judgment distance selecting, timer function of the control output and timer time selecting, instability output (IO-Link mode) ON delay timer time selecting function, monitor output, operating hours read-out, readout of the sensor internal temperature, and initial reset |
||||
IO-Link
Commun- ication specifica- tions *2 |
IO-Link
specification |
Ver 1.1 | |||
Baud rate | COM2 (38.4 kbps), COM3 (230.4 kbps) | ||||
Data length | PD size: 2 bytes, OD size: 1 byte (M-sequence type: TYPE_2_2) | ||||
Minimum cycle
time |
COM2: 2.3 ms, COM3: 0.4 ms | ||||
Accessories | Instruction manual, Clamping nuts, Toothed washer |
Size | M8 | M12 | |||
---|---|---|---|---|---|
Shielded | Shielded | Unshielded | Shielded | Unshielded | |
Model | E2E-X3D[] | E2E-X6MD[] | E2E-X7D[] | E2E-X10MD[] | |
Sensing distance | 3 mm ±10% | 6 mm ±10% | 7 mm ±10% | 10 mm ±10% | |
Setting distance *1 | 0 to 2.4 mm | 0 to 4.8 mm | 0 to 5.6 mm | 0 to 8 mm | |
Differential travel | 15% max. of sensing distance | ||||
Detectable object | Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to
Engineering Data on Catalog.) |
||||
Standard sensing object | Iron,
9 × 9 × 1 mm |
Iron,
18 × 18 × 1 mm |
Iron,
21 × 21 × 1 mm |
Iron,
30 × 30 × 1 mm |
|
Response frequency *2 | 350 Hz | 250 Hz | 350 Hz | 200 Hz | |
Power supply voltage | 10 to 30 VDC, (including 10% ripple (p-p)) | ||||
Leakage current | 0.8 mA max. | ||||
Control
output |
Load current | 3 to 100 mA | |||
Residual
voltage |
Polarity: 3 V max. (Load current: 100 mA, Cable length: 2 m)
No polarity: 5 V max. (Load current: 100 mA, Cable length: 2 m) |
||||
Indicator | D1 Models: Operation indicator (orange), Setting indicator (green)
D2 Models: Operation indicator (orange) |
||||
Operation mode | D1 Models: NO
D2 Models: NC Refer to the timing charts under I/O Circuit Diagrams on Catalog for details. |
||||
Protection circuits | Surge suppressor, Load short-circuit protection | ||||
Ambient temperature
range |
Operating: -25 to 70°C, Storage: -40 to 85°C (with no icing or condensation) | ||||
Ambient humidity range | Operating and Storage: 35% to 95% (with no condensation) | ||||
Temperature influence | ±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C | ||||
Voltage influence | ±1% max. of sensing distance at rated voltage in the rated voltage ±15% range | ||||
Insulation resistance | 50 MΩ min. (at 500 VDC) between current-carrying parts and case | ||||
Dielectric strength | 1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case | ||||
Vibration resistance
(destruction) |
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions | ||||
Shock resistance
(destruction) |
500 m/s2 10 times each in X, Y, and Z
directions |
1,000 m/s2 10 times each in X, Y, and Z
directions |
|||
Degree of protection | Pre-wired Models/Pre-wired Connector Models: IP67 (IEC 60529), IP67G *3 (JIS C 0920
Annex 1) Passed OMRON's Oil-resistant Component Evaluation Standards *4 (Cutting oil type: specified in JIS K 2241:2000, Temperature: 35 °C max.) and ISO 20653 (old standard: DIN 40050 PART9) IP69K |
||||
Connecting method | Pre-wired Models (Standard cable length: 2 m) and Pre-wired Connector Models (Standard
cable length: 0.3 m) |
||||
Weight
(packed state) |
Pre-wired
Models |
Approx. 60 g | Approx. 70 g | ||
Pre-wired
Connector Models |
Approx. 30 g | Approx. 40 g | |||
Materials | Case | Nickel-plated brass | Stainless steel
(SUS303) |
Nickel-plated brass | |
Sensing
surface |
Polybutylene terephthalate (PBT) | ||||
Clamping
nuts |
Nickel-plated brass | ||||
Toothed
washer |
Zinc-plated iron | ||||
Cable | Vinyl chloride (PVC) | ||||
Accessories | Instruction manual, Clamping nuts, Toothed washer |
Size | M18 | M30 | |||
---|---|---|---|---|---|
Shielded | Shielded | Unshielded | Shielded | Unshielded | |
Model | E2E-X11D[] | E2E-X20MD[] | E2E-X20D[] | E2E-X40MD[] | |
Sensing distance | 11 mm ±10% | 20 mm ±10% | 20 mm ±10% | 40 mm ±10% | |
Setting distance *1 | 0 to 8.8 mm | 0 to 16 mm | 0 to 16 mm | 0 to 32 mm | |
Differential travel | 15% max. of sensing distance | ||||
Detectable object | Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to
Engineering Data on Catalog.) |
||||
Standard sensing object | Iron,
33 × 33 × 1 mm |
Iron,
60 × 60 × 1 mm |
Iron,
60 × 60 × 1 mm |
Iron,
120 × 120 × 1 mm |
|
Response frequency *2 | 250 Hz | 200 Hz | 200 Hz | 50 Hz | |
Power supply voltage | 10 to 30 VDC, (including 10% ripple (p-p)) | ||||
Leakage current | 0.8 mA max. | ||||
Control
output |
Load current | 3 to 100 mA | |||
Residual
voltage |
Polarity: 3 V max. (Load current: 100 mA, Cable length: 2 m)
No polarity: 5 V max. (Load current: 100 mA, Cable length: 2 m) |
||||
Indicator | D1 Models: Operation indicator (orange), Setting indicator (green)
D2 Models: Operation indicator (orange) |
||||
Operation mode | D1 Models: NO
D2 Models: NC Refer to the timing charts under I/O Circuit Diagrams on Catalog for details. |
||||
Protection circuits | Surge suppressor, Load short-circuit protection | ||||
Ambient temperature
range |
Operating: -25 to 70°C, Storage: -40 to 85°C (with no icing or condensation) | ||||
Ambient humidity range | Operating and Storage: 35% to 95% (with no condensation) | ||||
Temperature influence | ±20% max. of sensing
distance at 23°C in the temperature range of -25 to 70°C |
±10% max. of sensing
distance at 23°C in the temperature range of -25 to 70°C |
±20% max. of sensing distance at 23°C in
the temperature range of -25 to 70°C |
||
Voltage influence | ±1% max. of sensing distance at rated voltage in the rated voltage ±15% range | ||||
Insulation resistance | 50 MΩ min. (at 500 VDC) between current-carrying parts and case | ||||
Dielectric strength | 1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case | ||||
Vibration resistance
(destruction) |
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions | ||||
Shock resistance
(destruction) |
1,000 m/s2 10 times each in X, Y, and Z directions | ||||
Degree of protection | Pre-wired Models/Pre-wired Connector Models: IP67 (IEC 60529), IP67G *3 (JIS C 0920
Annex 1) Passed OMRON's Oil-resistant Component Evaluation Standards *4 (Cutting oil type: specified in JIS K 2241:2000, Temperature: 35 °C max.) and ISO 20653 (old standard: DIN 40050 PART9) IP69K |
||||
Connecting method | Pre-wired Models (Standard cable length: 2 m) and Pre-wired Connector Models (Standard
cable length: 0.3 m) |
||||
Weight
(packed state) |
Pre-wired
Models |
Approx. 130 g | Approx. 150 g | Approx. 180 g | Approx. 210 g |
Pre-wired
Connector Models |
Approx. 70 g | Approx. 90 g | Approx.110 g | Approx. 140 g | |
Materials | Case | Nickel-plated brass | |||
Sensing
surface |
Polybutylene terephthalate (PBT) | ||||
Clamping
nuts |
Nickel-plated brass | ||||
Toothed
washer |
Zinc-plated iron | ||||
Cable | Vinyl chloride (PVC) | ||||
Accessories | Instruction manual, Clamping nuts, Toothed washer |
Size | M8 | M12 | |||
---|---|---|---|---|---|
Shielded | Shielded | Unshielded | Shielded | Unshielded | |
Item Model | E2E-X2D[] | E2E-X4MD[] | E2E-X3D[] | E2E-X8MD[] | |
Sensing distance | 2 mm ±10% | 4 mm ±10% | 3 mm ±10% | 8 mm ±10% | |
Setting distance *1 | 0 to 1.6 mm | 0 to 3.2 mm | 0 to 2.4 mm | 0 to 6.4 mm | |
Differential travel | 15% max. of sensing distance | 10% max. of sensing distance | |||
Detectable object | Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to
Engineering Data on Catalog.) |
||||
Standard sensing object | Iron,
8 × 8 × 1 mm |
Iron,
20 × 20 × 1 mm |
Iron,
12 × 12 × 1 mm |
Iron,
30 × 30 × 1 mm |
|
Response frequency *2 | 1.5 kHz | 1 kHz | 1 kHz | 0.8 kHz | |
Power supply voltage | 12 to 24 VDC (including 10% ripple (p-p)), Class 2 | ||||
Leakage current | 0.8 mA max. | ||||
Control
output |
Load current | 3 to 100 mA | |||
Residual
voltage |
Polarity: 3 V max. (Load current: 100 mA, Cable length: 2 m)
No polarity: 5 V max. (Load current: 100 mA, Cable length: 2 m) |
||||
Indicator | D1 Models: Operation indicator (orange), Setting indicator (green)
D2 Models: Operation indicator (orange) |
||||
Operation mode | D1 Models: NO
D2 Models: NC Refer to the timing charts under I/O Circuit Diagrams on Catalog for details. |
||||
Protection circuits | Surge suppressor, Load short-circuit protection | ||||
Ambient temperature range | Operating: -25 to 70°C, Storage: -40 to 85°C (with no icing or condensation) | ||||
Ambient humidity range | Operating and Storage: 35% to 95% (with no condensation) | ||||
Temperature influence | ±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C | ||||
Voltage influence | ±1% max. of sensing distance at rated voltage in the rated voltage ±15% range | ||||
Insulation resistance | 50 MΩ min. (at 500 VDC) between current-carrying parts and case | ||||
Dielectric strength | 1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case | ||||
Vibration resistance
(destruction) |
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions | ||||
Shock resistance
(destruction) |
500 m/s2 10 times each in X, Y, and Z
directions |
1,000 m/s2 10 times each in X, Y, and Z
directions |
|||
Degree of protection | Pre-wired Models/Pre-wired Connector Models:
IP67 (IEC 60529), IP67G *3 (JIS C 0920 Annex 1) Passed OMRON's Oil-resistant Component Evaluation Standards *4 (Cutting oil type: specified in JIS K 2241:2000, Temperature: 35°C max.) and ISO 20653 (old standard: DIN 40050 PART9) IP69K |
||||
Connecting method | Pre-wired Models (Standard cable length: 2 m), Pre-wired Connector Models (Standard
cable length: 0.3 m), M8 Connector Models and M12 Connector Models |
||||
Weight *5
(packed state) |
Pre-wired Models | Approx. 60 g | Approx. 70 g | ||
Pre-wired
Connector Models |
Approx. 30 g | Approx. 40 g | |||
Connector Models | Approx. 40 g (M8/M12 Connector) | Approx. 55 g | |||
Materials | Case | M8 Size: Stainless steel (SUS303), M12/M18/M30 Size: Nickel-plated brass | |||
Sensing surface | Polybutylene terephthalate (PBT) | ||||
Clamping nuts | Nickel-plated brass | ||||
Toothed washer | Zinc-plated iron | ||||
Cable | Vinyl chloride (PVC)
Note: Material of Pre-wired Models and Pre-wired Connector Models. |
||||
Accessories | Instruction manual, Clamping nuts, Toothed washer |
Size | M18 | M30 | |||
---|---|---|---|---|---|
Shielded | Shielded | Unshielded | Shielded | Unshielded | |
Item Model | E2E-X7D[] | E2E-X14MD[] | E2E-X10D[] | E2E-X20MD[] | |
Sensing distance | 7 mm ±10% | 14 mm ±10% | 10 mm ±10% | 20 mm ±10% | |
Setting distance *1 | 0 to 5.6 mm | 0 to 11.2 mm | 0 to 8 mm | 0 to 16 mm | |
Differential travel | 15% max. of sensing distance | 10% max. of sensing distance | |||
Detectable object | Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to
Engineering Data on Catalog.) |
||||
Standard sensing object | Iron,
18 × 18 × 1 mm |
Iron,
30 × 30 × 1 mm |
Iron,
30 × 30 × 1 mm |
Iron,
54 × 54 × 1 mm |
|
Response frequency *2 | 0.5 kHz | 0.4 kHz | 0.4 kHz | 0.1 kHz | |
Power supply voltage | 12 to 24 VDC (including 10% ripple (p-p)), Class 2 | ||||
Leakage current | 0.8 mA max. | ||||
Control
output |
Load current | 3 to 100 mA | |||
Residual
voltage |
Polarity: 3 V max. (Load current: 100 mA, Cable length: 2 m)
No polarity: 5 V max. (Load current: 100 mA, Cable length: 2 m) |
||||
Indicator | D1 Models: Operation indicator (orange), Setting indicator (green)
D2 Models: Operation indicator (orange) |
||||
Operation mode | D1 Models: NO
D2 Models: NC Refer to the timing charts under I/O Circuit Diagrams on Catalog for details. |
||||
Protection circuits | Surge suppressor, Load short-circuit protection | ||||
Ambient temperature range | Operating: -25 to 70°C, Storage: -40 to 85°C (with no icing or condensation) | ||||
Ambient humidity range | Operating and Storage: 35% to 95% (with no condensation) | ||||
Temperature influence | ±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C | ||||
Voltage influence | ±1% max. of sensing distance at rated voltage in the rated voltage ±15% range | ||||
Insulation resistance | 50 MΩ min. (at 500 VDC) between current-carrying parts and case | ||||
Dielectric strength | 1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case | ||||
Vibration resistance
(destruction) |
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions | ||||
Shock resistance
(destruction) |
1,000 m/s2 10 times each in X, Y, and Z directions | ||||
Degree of protection | Pre-wired Models/Pre-wired Connector Models:
IP67 (IEC 60529), IP67G *3 (JIS C 0920 Annex 1) Passed OMRON's Oil-resistant Component Evaluation Standards *4 (Cutting oil type: specified in JIS K 2241:2000, Temperature: 35°C max.) and ISO 20653 (old standard: DIN 40050 PART9) IP69K |
||||
Connecting method | Pre-wired Models (Standard cable length: 2 m), Pre-wired Connector Models (Standard
cable length: 0.3 m), M8 Connector Models and M12 Connector Models |
||||
Weight *5
(packed state) |
Pre-wired Models | Approx. 130 g | Approx. 150 g | Approx. 180 g | Approx. 210 g |
Pre-wired
Connector Models |
Approx. 70 g | Approx. 90 g | Approx. 110 g | Approx. 140 g | |
Connector Models | Approx. 85 g | Approx. 80 g | Approx. 160 g | Approx. 150 g | |
Materials | Case | M8 Size: Stainless steel (SUS303), M12/M18/M30 Size: Nickel-plated brass | |||
Sensing surface | Polybutylene terephthalate (PBT) | ||||
Clamping nuts | Nickel-plated brass | ||||
Toothed washer | Zinc-plated iron | ||||
Cable | Vinyl chloride (PVC)
Note: Material of Pre-wired Models and Pre-wired Connector Models. |
||||
Accessories | Instruction manual, Clamping nuts, Toothed washer |
Size | M12 | M18 | M30 | |||
---|---|---|---|---|---|---|
Shielded | Shielded | Unshielded | Shielded | Shielded | Unshielded | |
Item Model | E2E-X4D[] | E2E-X8D[] | E2E-X16MD[] | E2E-X15D[] | E2E-X30MD[] | |
Sensing distance | 4 mm ±10% | 8 mm ±10% | 16 mm ±10% | 15 mm ±10% | 30 mm ±10% | |
Setting distance *1 | 0 to 3.2 mm | 0 to 6.4 mm | 0 to 12.8 mm | 0 to 12 mm | 0 to 24 mm | |
Differential travel | 15% max. of sensing distance | |||||
Detectable object | Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to
Engineering Data on Catalog.) |
|||||
Standard sensing object | Iron,
12 × 12 × 1 mm |
Iron,
18 × 18 × 1 mm |
Iron,
45 × 45 × 1 mm |
Iron,
30 × 30 × 1 mm |
Iron,
70 × 70 × 1 mm |
|
Response frequency *2 | 1 kHz | 0.5 kHz | 0.4 kHz | 0.25 kHz | 0.1 kHz | |
Power supply voltage | 12 to 24 VDC (including 10% ripple (p-p)), Class 2 | |||||
Leakage current | 0.8 mA max. | |||||
Control
output |
Load current | 3 to 100 mA | ||||
Residual
voltage |
5 V max. (Load current: 100 mA, Cable length: 2 m) | |||||
Indicator | D1 Models: Operation indicator (orange), Setting indicator (green)
D2 Models: Operation indicator (orange) |
|||||
Operation mode | D1 Models: NO
D2 Models: NC Refer to the timing charts under I/O Circuit Diagrams on Catalog for details. |
|||||
Protection circuits | Surge suppressor, Load short-circuit protection | |||||
Ambient temperature
range |
Operating: -25 to 70°C, Storage: -40 to 85°C (with no icing or condensation) | |||||
Ambient humidity range | Operating and Storage: 35% to 95% (with no condensation) | |||||
Temperature influence | ±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C | |||||
Voltage influence | ±1% max. of sensing distance at rated voltage in the rated voltage ±15% range | |||||
Insulation resistance | 50 MΩ min. (at 500 VDC) between current-carrying parts and case | |||||
Dielectric strength | 1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case | |||||
Vibration resistance
(destruction) |
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions | |||||
Shock resistance
(destruction) |
500 m/s2 10 times
each in X, Y, and Z directions |
1,000 m/s2 10 times each in X, Y, and Z directions | ||||
Degree of protection | Pre-wired Models/Pre-wired Connector Models:
IP67 (IEC 60529), IP67G *3 (JIS C 0920 Annex 1) Passed OMRON's Oil-resistant Component Evaluation Standards *4 (Cutting oil type: specified in JIS K 2241:2000, Temperature: 35°C max.) and ISO 20653 (old standard: DIN 40050 PART9) IP69K |
|||||
Connecting method | Pre-wired Models (Standard cable length: 2 m), Pre-wired Connector Models (Standard
cable length: 0.3 m) |
|||||
Weight
(packed state) |
Pre-wired
Models |
Approx. 70 g | Approx. 130 g | Approx. 150 g | Approx. 180 g | Approx. 210 g |
Pre-wired
Connector Models |
Approx. 40 g | Approx. 70 g | Approx. 90 g | Approx. 110 g | Approx. 140 g | |
Materials | Case | Nickel-plated brass | ||||
Sensing surface | Polybutylene terephthalate (PBT) | |||||
Clamping nuts | Nickel-plated brass | |||||
Toothed washer | Zinc-plated iron | |||||
Cable | Vinyl chloride (PVC) | |||||
Accessories | Instruction manual, Clamping nuts, Toothed washer |
Size | M8 | M12 | M18 | |
---|---|---|---|---|
Shielded | Shielded | |||
Model | E2E-X1R5D[] | E2E-X2R5D[] | E2E-X5D[] | |
Sensing distance | 1.5 mm ±10% | 2.5 mm ±10% | 5 mm ±10% | |
Setting distance *1 | 0 to 1.2 mm | 0 to 2 mm | 0 to 4 mm | |
Differential travel | 10% max. of sensing distance | |||
Detectable object | Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to
Engineering Data on Catalog.) |
|||
Standard sensing object | Iron, 10 × 10 × 1 mm | Iron, 12 × 12 × 1 mm | Iron, 18 × 18 × 1 mm | |
Response frequency *2 | 250 Hz | 250 Hz | 250 Hz | |
Power supply voltage | 10 to 30 VDC, (including 10% ripple (p-p)) | |||
Leakage current | 0.8 mA max. | |||
Control
output |
Load current | 3 to 100 mA | ||
Residual
voltage |
Polarity: 3 V max. (Load current: 100 mA, Cable length: 2 m)
No polarity: 5 V max. (Load current: 100 mA, Cable length: 2 m) |
|||
Indicator | D1 Models: Operation indicator (orange), Setting indicator (green)
D2 Models: Operation indicator (orange) |
|||
Operation mode | D1 Models: NO
D2 Models: NC Refer to the timing charts under I/O Circuit Diagrams on Catalog for details. |
|||
Protection circuits | Surge suppressor, Load short-circuit protection | |||
Ambient temperature
range |
Operating: -25 to 70°C, Storage: -40 to 85°C (with no icing or condensation) | |||
Ambient humidity range | Operating and Storage: 35% to 95% (with no condensation) | |||
Temperature influence | ±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C | |||
Voltage influence | ±1% max. of sensing distance at rated voltage in the rated voltage ±15% range | |||
Insulation resistance | 50 MΩ min. (at 500 VDC) between current-carrying parts and case | |||
Dielectric strength | 1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case | |||
Vibration resistance
(destruction) |
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions | |||
Shock resistance
(destruction) |
500 m/s2 10 times each in X,
Y, and Z directions |
1,000 m/s2 10 times each in X, Y, and Z directions | ||
Degree of protection | Pre-wired Models/Pre-wired Connector Models: IP67 (IEC 60529), IP67G *3 (JIS C 0920
Annex 1) Passed OMRON's Oil-resistant Component Evaluation Standards *4 (Cutting oil type: specified in JIS K 2241:2000, Temperature: 35°C max.) and ISO 20653 (old standard: DIN 40050 PART9) IP69K |
|||
Connecting method | Pre-wired Models (Standard cable length: 2 m) and Pre-wired Connector Models (Standard
cable length: 0.3 m) |
|||
Weight
(packed state) |
Pre-wired
Models |
Approx. 60 g | Approx. 70 g | Approx. 130 g |
Pre-wired
Connector Models |
Approx. 30 g | Approx. 40 g | Approx. 70 g | |
Materials | Case | Stainless steel (SUS303) | Nickel-plated brass | |
Sensing
surface |
Polybutylene terephthalate (PBT) | |||
Clamping
nuts |
Nickel-plated brass | |||
Toothed
washer |
Zinc-plated iron | |||
Cable | Vinyl chloride (PVC) | |||
Accessories | Instruction manual, Clamping nuts, Toothed washer |
last update: October 2, 2023