CJ-series Position Control Units with EtherCAT interface
last update: October 1, 2015
Item | CJ1W-NC281/-NC481/-NC881/-NCF81/-NC482/-NC882/-NCF82 |
---|---|
Dimensions | 90 × 65 × 31 mm (H × D × W) |
Weight | 110 g max. |
Internal current consumption | 460 mA max. at 5 VDC |
Ambient operating temperature | 0 to 55°C |
Applicable standards | Conforms to cULus and EC Directives. |
Note: All other specifications conform to the general specifications of the CJ Series.
Item | Models | |||||
---|---|---|---|---|---|---|
Servo control only | ||||||
CJ1W-NC281 | CJ1W-NC481 | CJ1W-NC881 | CJ1W-NCF81 | |||
Applicable PLCs | CJ Series | |||||
Settable unit numbers | 0 to F (unit number as a CPU Bus Unit) | |||||
Maximum number of Units | 10 Units per Rack, 16 Units per PLC (Can be used on Expansion
Racks.) |
|||||
Allocated
I/O words |
Position Control Unit Control
Memory Areas |
25 words in CPU Bus Unit Area | ||||
Axis Operation Memory Areas | 43 words for each control axis (2 + 12 output words and 13 + 16
input words) in specified words in the CIO, Work, DM, or EM Area. |
|||||
Memory Operation Memory Areas | 7 words for each task (3 output words and 4 input words) in specified
words in the CIO, Work, DM, or EM Area |
|||||
I/O Memory Areas | --- | |||||
Controllable Servo Drives *1 | G5-series Servo Drives with Built-in EtherCAT Communications | |||||
Controllable encoder input terminal *2 *3 | --- | |||||
Control method | Control commands using EtherCAT communication | |||||
Number of controlled axes | 2 axes | 4 axes | 8 axes | 16 axes | ||
Maximum command output speed | 104 Mpps *4 | |||||
Control
units |
Setting unit | Pulses, millimeters, inches, or degrees | ||||
Unit multiplier *5 | ×1, ×10, ×100, ×1,000, or ×10,000 | |||||
Electronic gear ratio *5 | Unit version 1.1 or earlier: 1/1 to 1,048,576/1,048,576
Unit version 1.3 or later: 1/1 to 4,294,967,295/4,294,967,295 |
|||||
Positioning functions | Memory operation or direct operation | |||||
Single
axis control |
Position control | 2 axes | 4 axes | 8 axes | 16 axes | |
Speed control | 2 axes | 4 axes | 8 axes | 16 axes | ||
Inter-
polated control |
Linear interpolation | 2 axes max. | 4 axes max. | 4 axes max. | 4 axes max. | |
Circular interpolation | 2 axes | 2 axes | 2 axes | 2 axes | ||
Helical interpolation *3 | --- | --- | --- | --- | ||
Memory
operation |
Maximum number of
tasks |
2 | 4 | 4 *6 | 4 *6 | |
Sequence functions | JUMP, FOR-NEXT (50 layers/task), PSET, and PRSET | |||||
Dwell timers | 500/task, 0 to 10.00 s (Set in increments of 0.01 s.) | |||||
Position
command values |
Data | -2,147,483,648 to 2,147,483,647 command units *7 | ||||
Number of position command
values |
500/task | |||||
Speed
command values |
Data *8 | Position control: 1 to 2,147,483,647 command units/s
Speed control: -2,147,483,648 to 2,147,483,647 command units/s |
||||
Number of speed command values | 500/task | |||||
Accel-
eration times |
Data | 0 to 250,000 ms | ||||
Number of acceleration times | 500/task | |||||
Decel-
eration times |
Data | 0 to 250,000 ms | ||||
Number of deceleration times | 500/task | |||||
Auxiliary
functions |
Overrides | 0.01% to 500.00% (Can be set for each axis.) | ||||
Software limits | -2,147,483,647 to 2,147,483,646 command units (Can be set for
each axis.) |
|||||
Backlash compensation | Backlash compensation is performed using the compensation
function in the Servo Drive. The setting range depends on the specifications of the Servo Drive. |
|||||
Torque Limits | Unit version 1.1 or earlier: Supports only the ability to enable or
disable the torque limits by turning ON or OFF the command bits. Unit version 1.3 or later: Supports the ability to change the torque limit data via the Memory Area/Synchronous Data Link in addition to the ability to enable or disable the torque limits by turning ON or OFF the command bits. |
|||||
Synchronous Data Link function | None | |||||
Control
perfor- mance |
Control cycle | 0.5 ms | 0.5 ms when
using 1 to 2 axes 1 ms when using 3 to 4 axes |
0.5 ms when
using 1 to 2 axes 1 ms when using 3 to 4 axes 2 ms when using 5 to 8 axes |
0.5 ms when
using 1 to 2 axes 1 ms when using 3 to 4 axes 2 ms when using 5 to 16 axes |
|
Communications cycle | 250 µs | 250 µs when
using 1 to 4 axes 500 µs when using 5 to 8 axes |
250 µs when
using 1 to 4 axes 500 µs when using 5 to 10 axes 1.0 ms when using 11 to 16 axes |
|||
Starting
time *9 |
Direct operation
(high-speed PTP) *10 |
0.15 to 0.4 ms | 0.15 to 0.4 ms
when using 1 to 4 axes 0.15 to 0.8 ms when using 5 to 8 axes |
0.15 to 0.4 ms
when using 1 to 4 axes 0.15 to 0.8 ms when using 5 to 10 axes 0.15 to 1.2 ms when using 11 to 16 axes |
||
Direct operation
(bits) *11 |
0.75 to 1.25 ms | 1.25 to 2.25 ms | 2.5 to 4.5 ms | 3.0 to 5.0 ms | ||
Memory operation
(linear interpolation) *11 |
1.75 to 2.25 ms | 3.25 to 4.25 ms | 6.5 to 8.5 ms | 7.0 to 9.0 ms | ||
Control
I/O |
Servo
Drive interface |
Communications port | EtherCAT port × 1 | |||
Output signals | There are no external output signals for external outputs.
The following command bits are provided for each axis for Servo Drive control: Deviation Counter Reset Bit, Alarm Reset Bit, Servo Lock Bit, Servo Unlock Bit, and Torque Limit Bits. |
|||||
Input signals | There are no external input signals for external inputs.
The following status flags are provided for each axis for Servo Drive control: Origin Input Flag, Servo Drive Alarm Input Flag, and Positioning Completed Input Flag. |
|||||
External interface
signals *12 |
6 signals (external origin signal, origin proximity signal, forward limit
signal, reverse limit signal, emergency stop signal, and interrupt input signal) for each axis |
Item | Models | ||||
---|---|---|---|---|---|
Servo control + I/O communications | |||||
CJ1W-NC482 | CJ1W-NC882 | CJ1W-NCF82 | |||
Applicable PLCs | CJ Series | ||||
Settable unit numbers | 0 to F (unit number as a CPU Bus Unit) | ||||
Maximum number of Units | 10 Units per Rack, 16 Units per PLC (Can be used on Expansion
Racks.) |
||||
Allocated
I/O words |
Position Control Unit Control
Memory Areas |
25 words in CPU Bus Unit Area | |||
Axis Operation Memory Areas | 43 words for each control axis (2 + 12 output words and 13 + 16
input words) in specified words in the CIO, Work, DM, or EM Area. |
||||
Memory Operation Memory Areas | 7 words for each task (3 output words and 4 input words) in specified
words in the CIO, Work, DM, or EM Area |
||||
I/O Memory Areas | 1,300 words maximum (Outputs: 640 words, inputs: 640 words,
communications status: 20 words) in specified words in the CIO, Work, DM, or EM Area |
||||
Controllable Servo Drives *1 | G5-series Servo Drives with Built-in EtherCAT Communications | ||||
Controllable encoder input terminal *2 *3 | OMRON encoder input terminal GX-EC02[]1 | ||||
Control method | Control commands using EtherCAT communication | ||||
Number of controlled axes | 4 axes | 8 axes | 16 axes | ||
Maximum command output speed | 104 Mpps *4 | ||||
Control
units |
Setting unit | Pulses, millimeters, inches, or degrees | |||
Unit multiplier *5 | ×1, ×10, ×100, ×1,000, or ×10,000 | ||||
Electronic gear ratio *5 | Unit version 1.1 or earlier: 1/1 to 1,048,576/1,048,576
Unit version 1.3 or later: 1/1 to 4,294,967,295/4,294,967,295 |
||||
Positioning functions | Memory operation or direct operation | ||||
Single
axis control |
Position control | 4 axes | 8 axes | 16 axes | |
Speed control | 4 axes | 8 axes | 16 axes | ||
Inter-
polated control |
Linear interpolation | 4 axes max. | 4 axes max. | 4 axes max. | |
Circular interpolation | 2 axes | 2 axes | 2 axes | ||
Helical interpolation *3 | 3 axes | 3 axes | 3 axes | ||
Memory
operation |
Maximum number of
tasks |
4 | 4 *6 | 4 *6 | |
Sequence functions | JUMP, FOR-NEXT (50 layers/task), PSET, and PRSET | ||||
Dwell timers | 500/task, 0 to 10.00 s (Set in increments of 0.01 s.) | ||||
Position
command values |
Data | -2,147,483,648 to 2,147,483,647 command units *7 | |||
Number of position command
values |
500/task | ||||
Speed
command values |
Data *8 | Position control: 1 to 2,147,483,647 command units/s
Speed control: -2,147,483,648 to 2,147,483,647 command units/s |
|||
Number of speed command values | 500/task | ||||
Accel-
eration times |
Data | 0 to 250,000 ms | |||
Number of acceleration times | 500/task | ||||
Decel-
eration times |
Data | 0 to 250,000 ms | |||
Number of deceleration times | 500/task | ||||
Auxiliary
functions |
Overrides | 0.01% to 500.00% (Can be set for each axis.) | |||
Software limits | -2,147,483,647 to 2,147,483,646 command units (Can be set for
each axis.) |
||||
Backlash compensation | Backlash compensation is performed using the compensation
function in the Servo Drive. The setting range depends on the specifications of the Servo Drive. |
||||
Torque Limits | Unit version 1.1 or earlier: Supports only the ability to enable or
disable the torque limits by turning ON or OFF the command bits. Unit version 1.3 or later: Supports the ability to change the torque limit data via the Memory Area/Synchronous Data Link in addition to the ability to enable or disable the torque limits by turning ON or OFF the command bits. |
||||
Synchronous Data Link function | Unit version 1.1 or earlier: None.
Unit version 1.3 or later: Provides command support for velocity command data, torque command data, torque feedforward data, torque limit data, and velocity limitation value when used in conjunction with a CJ2H-CPU (unit version 1.4 or later). Unit version 1.5 or later: Provides command support for electronic cam operation. |
||||
Control
perfor- mance |
Control cycle | 0.5 ms when
using 1 to 2 axes 1 ms when using 3 to 4 axes |
0.5 ms when using 1 to
2 axes 1 ms when using 3 to 4 axes 2 ms when using 5 to 8 axes |
0.5 ms when using 1 to
2 axes 1 ms when using 3 to 4 axes 2 ms when using 5 to 16 axes |
|
Communications cycle | 250 µs | 250 µs when using 1 to
4 axes 500 µs when using 5 to 8 axes |
250 μs min. when
using 1 to 4 axes 500 μs min. when using 5 to 10 axes 1.0 ms when using 11 to 16 axes |
||
Starting
time *9 |
Direct operation
(high-speed PTP) *10 |
0.15 to 0.4 ms | 0.15 to 0.4 ms when
using 1 to 4 axes 0.15 to 0.8 ms when using 5 to 8 axes |
0.15 to 0.4 ms when
using 1 to 4 axes 0.15 to 0.8 ms when using 5 to 10 axes 0.15 to 1.2 ms when using 11 to 16 axes |
|
Direct operation
(bits) *11 |
1.25 to 2.25 ms | 2.5 to 4.5 ms | 3.0 to 5.0 ms | ||
Memory operation
(linear interpolation) *11 |
3.25 to 4.25 ms | 6.5 to 8.5 ms | 7.0 to 9.0 ms | ||
Control
I/O |
Servo
Drive interface |
Communications port | EtherCAT port × 1 | ||
Output signals | There are no external output signals for external outputs.
The following command bits are provided for each axis for Servo Drive control: Deviation Counter Reset Bit, Alarm Reset Bit, Servo Lock Bit, Servo Unlock Bit, and Torque Limit Bits. |
||||
Input signals | There are no external input signals for external inputs.
The following status flags are provided for each axis for Servo Drive control: Origin Input Flag, Servo Drive Alarm Input Flag, and Positioning Completed Input Flag. |
||||
External interface
signals *12 |
6 signals (external origin signal, origin proximity signal, forward limit
signal, reverse limit signal, emergency stop signal, and interrupt input signal) for each axis |
Item | Characteristics | ||||||
---|---|---|---|---|---|---|---|
Servo control only | Servo control +
I/O communications |
||||||
CJ1W-
NC281 |
CJ1W-
NC481 |
CJ1W-
NC881 |
CJ1W-
NCF81 |
CJ1W-
NC482 |
CJ1W-
NC882 |
CJ1W-
NCF82 |
|
Communications
standard |
IEC 61158 Type12 | ||||||
Physical layer | 100Base-TX (IEEE802.3) | ||||||
Connector | RJ45 shielded connector × 1 | ||||||
Communications
media |
Category 5 or higher (Recommended: cable with double, aluminum tape and braided shielding) | ||||||
Communications
distance |
100 m max. between nodes | ||||||
Topology | Daisy chain only *1 | ||||||
EtherCAT Master
Specifications |
Class B (minimum master-CoE compatible (no information service for SDO)) | ||||||
Maximum number
of slaves *2 |
2 | 4 | 8 | 16 | 68 | 72 | 80 |
Node address
setting range |
1 to 2 | 1 to 4 | 1 to 8 | 1 to 16 | 1 to 4 and
17 to 80 *3 |
1 to 8 and
17 to 80 *3 |
1 to 16 and
17 to 80 *3 |
Communications
cycle *4 |
250 µs, 500 µs, 1 ms, or 2 ms | ||||||
Process data | Fixed PDO mappings specified for the slaves are used (set using Support Software). | ||||||
Mail box (CoE) | Emergency messages, SDO requests, SDO responses, and SDO information (Used for Position
Control Unit communications control and slave device parameter transfers.) |
||||||
LED indicators | ECAT RUN × 1
ECAT ERR × 1 L/A (Link/Activity) × 1 |
||||||
CiA402 drive
profile *5 |
• Cyclic synchronous position mode
• Cyclic synchronous velocity mode • Cyclic synchronous torque mode • Touch probe function • Torque limit function |
The Position Control Unit has the memory of up to 640 bytes for inputs and 640 bytes for outputs to be used for PDO communications.
The number of slaves that can be connected to the CJ1W-NC482/NC882/NCF82 is determined by the maximum memory size for PDO communications.
The memory of the PDO communication is shared with the Servo Drives; therefore, the number of I/O slaves that can be connected changes with the number of G5 Series Servo Drive (number of use axes) that are connected to the Position Control Unit.
Number of Servo Drive axes |
Size used by Servo Drive axes (bytes) * |
Remaining PDO communications memory size (bytes) |
Number of slaves that can be connected according to slave I/O size (guidelines) |
||||
---|---|---|---|---|---|---|---|
IN | OUT |
8 bytes of I/O (4 input and 4 output bytes) |
16 bytes of I/O (8 input and 8 output bytes) |
32 bytes of I/O (16 input and 16 output bytes) |
64 bytes of I/O (32 input and 32 output bytes) |
||
0 axis | 0 | 640 | 640 | 64 | 64 | 40 | 20 |
1 axis | 29 | 611 | 611 | 64 | 64 | 38 | 19 |
2 axes | 58 | 582 | 582 | 64 | 64 | 36 | 18 |
4 axes | 116 | 524 | 524 | 64 | 64 | 32 | 16 |
8 axes | 232 | 408 | 408 | 64 | 51 | 25 | 12 |
16 axes | 464 | 176 | 176 | 64 | 22 | 11 | 5 |
* The G5-series Servo Drives also use IN and OUT bytes. The factory default of the PDO communications size is 29 bytes.
The following functions are supported when the Position Control Unit is connected to an EtherCAT-compatible OMNUC G5-series Servo Drive.
Function | Description | ||
---|---|---|---|
Control
functions |
Single axis
control |
Absolute movements | Positioning is performed by specifying the absolute or relative target
position and target speed directly from the ladder program. |
Relative movements | |||
Speed control | Feeding at a specified speed is performed by specifying the target
speed directly from the ladder program. Speed control is implemented using speed feeding with position control. |
||
Interrupt feeding | Interrupt feeding can be used to move a specified amount when an
interrupt input is received during an absolute movement, a relative movement, or speed control. |
||
Rotation axis
control |
Rotation axes that are suitable for feeder and index table control can
be controlled. Forward and reverse positioning and shortest route operations are possible. |
||
Changing target
positions and target speeds |
The target position or target speed can be changed during an
absolute movement, a relative movement, or speed control. |
||
Multi-axis
control |
Linear interpolation | The operation of more than one axis is started and stopped
simultaneously to move in a straight line to the target position from the starting point of each axis. Linear interpolation is possible for up to four axes. |
|
Circular
interpolation |
The operation of any two axes is controlled to move in a circular arc.
Any of three methods can be used to specify a circular arc: specifying the target position and center point, specifying the target position, radius, and direction and specifying the target position and passing point. |
||
Helical interpolation | Helical interpolation is performed by giving one more axis to circular
interpolation. The number of turns can be specified. This function is available with CJ1W-NC[]82 (unit version 1.5 or later). |
||
Memory
operation |
Automatic
continuous operation |
The target positions, speeds, and operation patterns can be set in
advance in the Position Control Unit to automatically perform a series of operations. Continuous positioning and speed changes are also possible. |
|
Sequence functions | Memory operation data provides sequence functions, including
repetition of a given operation and starting/stopping operation data by using external inputs. Therefore, the Position Control Unit can perform various operation sequences without affecting the ladder programming in the CPU Unit. |
||
Manual
operation |
Origin searches | External sensors and other means are used to detect the
mechanical origin of the system. You can select the origin search operation that is best for your system from 15 different origin search operation patterns. |
|
Origin returns | You can return to the point that was defined as the mechanical
origin. |
||
Presetting the present position | The present position can be changed to a specified value to define
the origin. |
||
Deceleration stops and emergency
stops |
An axis that is in operation can be decelerated to a stop or stopped
immediately. |
||
Jogging | You can jog either forward or in reverse. | ||
Inching | You can inch either forward or in reverse. | ||
Synchronous Data Link | The CJ1W-NC[]82 (unit version 1.3 or later) can perform data
exchange between the CPU and Position Control Unit at regular intervals when used in conjunction with a CJ2H CPU (unit version 1.4 or later). In addition, you can use this function to perform synchronous feeding position, synchronous feeding velocity, and synchronous feeding torque control. Also, optional commands are available for torque feedforward data, torque limit data, and velocity limitation value. CJ1W-NC[]82 (unit version 1.5 or later) supports command for electronic cam operation as well. |
||
Auxiliary
control functions |
Command unit setting | You can set the unit of control for each axis according to the
machine. |
|
Acceler-
ation/ deceler- ation control |
Automatic
acceleration/ deceleration control |
The acceleration/deceleration curve can be automatically created
during operation. You can select either a trapezoidal curve or an S curve based on a tertiary function. |
|
Changing
acceleration/ deceleration rates |
You can change the rate of acceleration/deceleration during
acceleration/deceleration. |
||
Switching
acceleration/ deceleration points |
You can select one of three methods to connect speeds between
different operation patterns during continuous memory operation. |
||
Overrides | You can increase or decrease the operating speed of the system by
a specified factor. |
||
Backlash compensation | You can compensate for mechanical play using a parameter. | ||
M codes | M codes can be output during memory operation to interlock with
external devices. |
||
Zone settings | You can set zones and assess when the present position is in a
zone. Up to three zones can be set for each axis. |
||
Support for absolute encoders | You can build an absolute positioning system by using a Servomotor
with an Absolute Encoder. The Position Control Units can be used together with OMRON's G5-series Servomotors with Absolute Encoders. |
||
Teaching | You can save the present position as position data for memory
operation.You can use either the command present position or feedback present position. |
||
Torque limit outputs | The torque limit outputs can be used to switch the torque limits of
the Servo Drive. They can be turned ON and OFF directly from a ladder program. Torque limits can be automatically switched by using holding for an origin search operation. In addition, you can change the torque limit data via the Synchronous Data Link by using the CJ1W-NC[]82 (unit version 1.3 or later) in conjunction with a CJ2H-CPU (unit version 1.4 or later) and G5-series Servo Drive (version 2.0 or later). Also, you can change the torque limit data via the Memory Area by using the CJ1W-NC[]81/-NC[]82 (unit version 1.3 or later) in conjunction with a G5-series Servo Drive (version 2.0 or later). |
||
Monitoring
functions |
Software limits | You can set forward and reverse software limits for axis operation.
If the target position exceeds a software limit, it will be detected in the command value check that is performed at startup. |
|
Monitoring position/
speed deviations |
The Position Control Unit monitors the position or speed deviation
between the present command position and present feedback position. You can stop axis operation if the deviation is too large. |
||
Monitoring deviation
between axes |
The deviation between axes is also monitored during linear
interpolation. You can stop axis operation if the deviation is too large. |
Functions available when connected with OMRON encoder input terminal GX-EC02[]1 are as shown below.
They are available with CJ1W-NC[]82, unit version 1.5 or later.
Function | Description | |
---|---|---|
Manual
operation |
Present position preset | The present position can be changed to a specified value to define the origin. |
Auxiliary
control functions |
Command unit setting | You can set the unit of control for each axis according to the machine. |
Zone settings | You can set a zone to check if the present position is in the set zone.
Up to three zones can be set for each axis. |
|
Present position latch | The position data when an external control input (latch A) is detected at the
encoder input terminal is stored in the Position Control Unit. |
|
Origin position latch | The position data when an external control input (latch B) is detected at the
encoder input terminal is stored in the Position Control Unit. |
last update: October 1, 2015