Two-circuit Limit Switch
Product Format | Product Description | CAD Download |
---|---|---|
WLCA2-N | Two-circuit Limit Switch, Roller lever (R38 mm), Pretravel (PT): 15±5 °, Conduit size: G1/2 (without ground terminal) |
![]() ![]() |
WLCA2-2-N | Two-circuit Limit Switch, Roller lever (R38 mm), Pretravel (PT): 25±5 °, Conduit size: G1/2 (without ground terminal) |
![]() ![]() |
WLCA2-2N-N | Two-circuit Limit Switch, Roller lever (R38 mm), Pretravel (PT): 20 ° max., Conduit size: G1/2 (without ground terminal) |
![]() ![]() |
WLCA2-7-N | Two-circuit Limit Switch, Roller lever (R50 mm), Pretravel (PT): 15±5 °, Conduit size: G1/2 (without ground terminal) |
![]() ![]() |
WLCA2-8-N | Two-circuit Limit Switch, Roller lever (R63 mm), Pretravel (PT): 15±5 °, Conduit size: G1/2 (without ground terminal) |
![]() ![]() |
WLCA2-LDK13-N | Two-circuit Limit Switch, Roller lever (R38 mm), Pretravel (PT): 15±5 °, With operation indicator (LED), Direct-wire connector (M12), DC Voltage NO wiring (NO③④) |
![]() ![]() |
WLCA2-LD-M1J-N | Two-circuit Limit Switch, Roller lever (R38 mm), Pretravel (PT): 15±5 °, With operation indicator (LED), Pre-wired connector (M12), DC Voltage NO wiring (NO③④) |
![]() ![]() |
WLCA2-LD-N | Two-circuit Limit Switch, Roller lever (R38 mm), Pretravel (PT): 15±5 °, With operation indicator (LED), Conduit size: G1/2 (without ground terminal) |
![]() ![]() |
WLCA2-LE-N | Two-circuit Limit Switch, Roller lever (R38 mm), Pretravel (PT): 15±5 °, With operation indicator (Neon lamp), Conduit size: G1/2 (without ground terminal) |
![]() ![]() |
WLCA12-N | Two-circuit Limit Switch, Adjustable roller lever (R25 to 89 mm), Pretravel (PT): 15±5 °, Conduit size: G1/2 (without ground terminal) |
![]() ![]() |
WLCA12-2-N | Two-circuit Limit Switch, Adjustable roller lever (R25 to 89 mm), Pretravel (PT): 25±5 °, Conduit size: G1/2 (without ground terminal) |
![]() ![]() |
WLCA12-2N-N | Two-circuit Limit Switch, Adjustable roller lever (R25 to 89 mm), Pretravel (PT): 20 ° max., Conduit size: G1/2 (without ground terminal) |
![]() ![]() |
WLCA32-41-N | Two-circuit Limit Switch, Fork Lock Lever A, Pretravel (PT): 55 ° max., Conduit size: G1/2 (without ground terminal) |
![]() ![]() |
WLCA32-42-N | Two-circuit Limit Switch, Fork Lock Lever B, Pretravel (PT): 55 ° max., Conduit size: G1/2 (without ground terminal) |
![]() ![]() |
WLCA32-43-N | Two-circuit Limit Switch, Fork Lock Lever C, Pretravel (PT): 55 ° max., Conduit size: G1/2 (without ground terminal) |
![]() ![]() |
WLCA32-44-N | Two-circuit Limit Switch, Fork Lock Lever D, Pretravel (PT): 55 ° max., Conduit size: G1/2 (without ground terminal) |
![]() ![]() |
WLCAL4-N | Two-circuit Limit Switch, Adjustable rod lever (350 to 380 mm), Pretravel (PT): 15±5 °, Conduit size: G1/2 (without ground terminal) |
![]() ![]() |
WLCAL5-N | Two-circuit Limit Switch, Rod spring lever, Pretravel (PT): 15±5 °, Conduit size: G1/2 (without ground terminal) |
![]() ![]() |
WLCL-N | Two-circuit Limit Switch, Adjustable rod lever (25 to 140 mm), Pretravel (PT): 15±5 °, Conduit size: G1/2 (without ground terminal) |
![]() ![]() |
WLCL-2-N | Two-circuit Limit Switch, Adjustable rod lever (25 to 140 mm), Pretravel (PT): 25±5 °, Conduit size: G1/2 (without ground terminal) |
![]() ![]() |
WLCL-2N-N | Two-circuit Limit Switch, Adjustable rod lever (25 to 140 mm), Pretravel (PT): 20 ° max., Conduit size: G1/2 (without ground terminal) |
![]() ![]() |
WLD2-N | Two-circuit Limit Switch, Top-roller plunger, Pretravel (PT): 1.7 mm max., Conduit size: G1/2 (without ground terminal) |
![]() ![]() |
WLD18-N | Two-circuit Limit Switch, Sealed top plunger, Pretravel (PT): 1.7 mm max., Conduit size: G1/2 (without ground terminal) |
![]() ![]() |
WLD28-N | Two-circuit Limit Switch, Sealed top-roller plunger, Pretravel (PT): 1.7 mm max., Conduit size: G1/2 (without ground terminal) |
![]() ![]() |
WLD38-N | Two-circuit Limit Switch, Sealed top-ball plunger, Pretravel (PT): 1.7 mm max., Conduit size: G1/2 (without ground terminal) |
![]() ![]() |
WLG12 | Two-circuit Limit Switch, High-sensitivity, Adjustable roller lever (R25 to 89 mm), Pretravel (PT): 9 to 12 °, Screw terminals (Conduit size: G1/2) |
![]() ![]() |
WLG2 | Two-circuit Limit Switch, Roller lever (R38 mm), High-sensitivity, Pretravel (PT): 9 to 12 °, Screw terminals (Conduit size: G1/2) |
![]() ![]() |
WLG2-55LD-DGJ03 | Two-circuit Limit Switch, Airtight Built-in Switch, Roller lever (R38 mm), High-sensitivity, With operation indicator (LED), Pretravel (PT): 9 to 12 °, NC+NO wiring (NO③④/NC①②), Pre-wired connectors (M12 Threaded) |
![]() ![]() |
WLG2-55LD-M1GJ | Two-circuit Limit Switch, Airtight Built-in Switch, Roller lever (R38 mm), High-sensitivity, With operation indicator (LED), Pretravel (PT): 9 to 12 °, NO wiring (NO①④), Pre-wired connectors (M12 Threaded) |
![]() ![]() |
WLG2-55LD-M1J | Two-circuit Limit Switch, Airtight Built-in Switch, Roller lever (R38 mm), High-sensitivity, With operation indicator (LED), Pretravel (PT): 9 to 12 °, NO wiring (NO③④), Pre-wired connectors (M12 Threaded) |
![]() ![]() |
WLG2-LDK43 | Two-circuit Limit Switch, Roller lever (R38 mm), High-sensitivity, With operation indicator (LED), Pretravel (PT): 9 to 12 °, NC+NO wiring (NO③④/NC①②), Direct-wire connector |
![]() ![]() |
WLG2-LDS-DTGJS03 | Two-circuit Limit Switch, Spatter-prevention, Roller lever (R38 mm), High-sensitivity, Allen-head Lever, With operation indicator (LED), Pretravel (PT): 9 to 12 °, NO wiring (NO①④), Pre-wired connectors (Smartclick) |
![]() ![]() |
WLGCA2 | Two-circuit Limit Switch, Roller lever (R38 mm), High-precision, Pretravel (PT): 5 to 7 °, Screw terminals (Conduit size: G1/2) |
![]() ![]() |
WLGCA2-55 | Two-circuit Limit Switch, Airtight Built-in Switch, Roller lever (R38 mm), High-precision, Pretravel (PT): 5 to 7 °, Screw terminals (Conduit size: G1/2) |
![]() ![]() |
WLGCA2-55LD | Two-circuit Limit Switch, Airtight Built-in Switch, Roller lever (R38 mm), High-precision, With operation indicator (LED), Pretravel (PT): 5 to 7 °, Screw terminals (Conduit size: G1/2) |
![]() ![]() |
WLGCA2-55LD-DGJ03 | Two-circuit Limit Switch, Airtight Built-in Switch, Roller lever (R38 mm), High-precision, With operation indicator (LED), Pretravel (PT): 5 to 7 °, NC+NO wiring (NO③④/NC①②), Pre-wired connectors (M12 Threaded) |
![]() ![]() |
WLGCA2-55LD-M1GJ | Two-circuit Limit Switch, Airtight Built-in Switch, Roller lever (R38 mm), High-precision, With operation indicator (LED), Pretravel (PT): 5 to 7 °, NO wiring (NO①④), Pre-wired connectors (M12 Threaded) |
![]() ![]() |
WLGCA2-55LD-M1J | Two-circuit Limit Switch, Airtight Built-in Switch, Roller lever (R38 mm), High-precision, With operation indicator (LED), Pretravel (PT): 5 to 7 °, NO wiring (NO③④), Pre-wired connectors (M12 Threaded) |
![]() ![]() |
WLGCA2-LD | Two-circuit Limit Switch, Roller lever (R38 mm), High-precision, With operation indicator (LED), Pretravel (PT): 5 to 7 °, Screw terminals (Conduit size: G1/2) |
![]() ![]() |
WLGCA2-LE | Two-circuit Limit Switch, Roller lever (R38 mm), High-precision, With operation indicator (Neon lamp), Pretravel (PT): 5 to 7 °, Screw terminals (Conduit size: G1/2) |
![]() ![]() |
WLGL | Two-circuit Limit Switch, Adjustable rod lever (25 to 140 mm), High-sensitivity, Pretravel (PT): 9 to 12 °, Screw terminals (Conduit size: G1/2) |
![]() ![]() |
WLMCA2-LD-N | Two-circuit Limit Switch, Long-life Switch, Roller lever (R38 mm), Pretravel (PT): 15±5 °, With operation indicator (LED), Conduit size: G1/2 (without ground terminal) |
![]() ![]() |
WLMG2-LD | Two-circuit Limit Switch, Long-life Switches, Roller lever (R38 mm), High-sensitivity, With operation indicator (LED), Pretravel (PT): 9 to 12 °, Screw terminals (Conduit size: G1/2) |
![]() ![]() |
WLMG2-LDK13 | Two-circuit Limit Switch, Long-life Switches, Roller lever (R38 mm), High-sensitivity, With operation indicator (LED), Pretravel (PT): 9 to 12 °, NO wiring (NO③④), Direct-wire connector |
![]() ![]() |
WLMG2-LDK43 | Two-circuit Limit Switch, Long-life Switches, Roller lever (R38 mm), High-sensitivity, With operation indicator (LED), Pretravel (PT): 9 to 12 °, NC+NO wiring (NO③④/NC①②), Direct-wire connector |
![]() ![]() |
WLMGCA2-LD | Two-circuit Limit Switch, Long-life Switches, Roller lever (R38 mm), High-precision, With operation indicator (LED), Pretravel (PT): 5 to 7 °, Screw terminals (Conduit size: G1/2) |
![]() ![]() |
WLMGCA2-LDK13 | Two-circuit Limit Switch, Long-life Switches, Roller lever (R38 mm), High-precision, With operation indicator (LED), Pretravel (PT): 5 to 7 °, NO wiring (NO③④), Direct-wire connector |
![]() ![]() |
WLMGCA2-LDK43 | Two-circuit Limit Switch, Long-life Switches, Roller lever (R38 mm), High-precision, With operation indicator (LED), Pretravel (PT): 5 to 7 °, NC+NO wiring (NO③④/NC①②), Direct-wire connector |
![]() ![]() |
WLNJ-2-N | Two-circuit Limit Switch, Flexible rod (Resin rod 8 dia.), Pretravel (PT): 40±20 mm, Conduit size: G1/2 (without ground terminal) |
![]() ![]() |
WLNJ-30-N | Two-circuit Limit Switch, Coil spring (4.8 dia.), Pretravel (PT): 20±10 mm, Conduit size: G1/2 (without ground terminal) |
![]() ![]() |
WLNJ-N | Two-circuit Limit Switch, Coil spring (6.5 dia.), Pretravel (PT): 20±10 mm, Conduit size: G1/2 (without ground terminal) |
![]() ![]() |
WLNJ-S2-N | Two-circuit Limit Switch, Flexible rod (Steel wire, 1 dia.), Pretravel (PT): 40±20 mm, Conduit size: G1/2 (without ground terminal) |
![]() ![]() |
WLSD-N | Two-circuit Limit Switch, Horizontal plunger, Pretravel (PT): 2.8 mm max., Conduit size: G1/2 (without ground terminal) |
![]() ![]() |
WLSD2-N | Two-circuit Limit Switch, Horizontal-roller plunger, Pretravel (PT): 2.8 mm max., Conduit size: G1/2 (without ground terminal) |
![]() ![]() |
WLSD3-N | Two-circuit Limit Switch, Horizontal-ball plunger, Pretravel (PT): 2.8 mm max., Conduit size: G1/2 (without ground terminal) |
![]() ![]() |